authorzbao <fishbaozi@gmail.com>2015-11-05 19:33:53 +0800
committerZheng Bao <zheng.bao@amd.com>2015-11-06 07:51:46 +0100
commiteb90aaf29e5c09612f964f0946a4ced53d88a913 (patch)
tree106d1686e5b7392def5865a4d2ec9909988818c0 /src/vendorcode
parentd5d94ea90a9402b480cde91febe1dc7d85f626b5 (diff)
downloadcoreboot-staging-eb90aaf29e5c09612f964f0946a4ced53d88a913.zip
coreboot-staging-eb90aaf29e5c09612f964f0946a4ced53d88a913.tar.gz
AMD bettong: Fix the interrupt routing.
The plugged devices on PCIe should use IOAPIC2 instead of standard IOAPIC1. The entries in IOAPIC2 count from the end of IOAPIC1. The unchanged code worked because the OS uses MSI instead APIC. To test that, boot linux with parameter pci=nomsi and see if the devices like NIC work well as they do without the booting parameter. Change-Id: I893e73f2aab3227381e44406fa285613e4ba2904 Signed-off-by: Zheng Bao <zheng.bao@amd.com> Signed-off-by: Zheng Bao <fishbaozi@gmail.com> Reviewed-on: http://review.coreboot.org/11374 Tested-by: build bot (Jenkins) Reviewed-by: Patrick Georgi <pgeorgi@google.com>