summaryrefslogtreecommitdiffstats
path: root/PCBSD/pc-sysinstall/backend/parseconfig.sh
blob: a86d58376e013c9ca7d073afdda24df34f181c09 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
#!/bin/sh
# Main install configuration parsing script
#

# Source our functions scripts
. ${BACKEND}/functions.sh
. ${BACKEND}/functions-bsdlabel.sh
. ${BACKEND}/functions-cleanup.sh
. ${BACKEND}/functions-disk.sh
. ${BACKEND}/functions-extractimage.sh
. ${BACKEND}/functions-installcomponents.sh
. ${BACKEND}/functions-localize.sh
. ${BACKEND}/functions-mountdisk.sh
. ${BACKEND}/functions-networking.sh
. ${BACKEND}/functions-newfs.sh
. ${BACKEND}/functions-parse.sh
. ${BACKEND}/functions-runcommands.sh
. ${BACKEND}/functions-unmount.sh
. ${BACKEND}/functions-upgrade.sh
. ${BACKEND}/functions-users.sh

# Check that the config file exists
if [ ! -e "${1}" ]
then
  echo "ERROR: Install configuration $1 does not exist!"
  exit 1
fi

# Set our config file variable
CFGF="$1"

# Check the dirname of the provided CFGF and make sure its a full path
DIR="`dirname ${CFGF}`"
if [ "${DIR}" = "." ]
then
  CFGF="`pwd`/${CFGF}"
fi
export CFGF

# Start by doing a sanity check, which will catch any obvious mistakes in the config
file_sanity_check "installMode disk0 partition bootManager installType installMedium packageType"

# We passed the Sanity check, lets grab some of the universal config settings and store them
check_value installMode "fresh upgrade"
check_value bootManager "bsd none"
check_value installType "PCBSD FreeBSD"
check_value installMedium "dvd usb ftp rsync LiveCD"
check_value packageType "uzip tar rsync split cpdup"
check_value partition "all ALL s1 s2 s3 s4 free FREE"
if_check_value_exists mirrorbal "load prefer round-robin split"

# We passed all sanity checks! Yay, lets start the install
echo "File Sanity Check -> OK"

# Lets load the various universal settings now
get_value_from_cfg installMode
INSTALLMODE="${VAL}" ; export INSTALLMODE

get_value_from_cfg installType
INSTALLTYPE="${VAL}" ; export INSTALLTYPE

get_value_from_cfg installMedium
INSTALLMEDIUM="${VAL}" ; export INSTALLMEDIUM

get_value_from_cfg packageType
PACKAGETYPE="${VAL}" ; export PACKAGETYPE

# Check if we are doing any networking setup
start_networking

# If we are not doing an upgrade, lets go ahead and setup the disk
if [ "${INSTALLMODE}" = "fresh" ]
then

  # Lets start setting up the disk slices now
  setup_disk_slice
  
  # Disk setup complete, now lets parse WORKINGSLICES and setup the bsdlabels
  setup_disk_label
  
  # Now we've setup the bsdlabels, lets go ahead and run newfs / zfs 
  # to setup the filesystems
  setup_filesystems

  # Lets mount the partitions now
  mount_all_filesystems

  # We are ready to begin extraction, lets start now
  init_extraction

  # Check if we have any optional modules to load 
  install_components

  # Do any localization in configuration
  run_localize
  
  # Save any networking config on the installed system
  save_networking_install

  # Now add any users
  setup_users

  # Now run any commands specified
  run_commands
  
  # Do any last cleanup / setup before unmounting
  run_final_cleanup

  # Unmount and finish up
  unmount_all_filesystems

  echo_log "Installation finished!"
  exit 0

else
  # We're going to do an upgrade, skip all the disk setup 
  # and start by mounting the target drive/slices
  mount_upgrade
  
  # Start the extraction process
  init_extraction

  # Do any localization in configuration
  run_localize

  # Now run any commands specified
  run_commands
  
  # Merge any old configuration files
  merge_old_configs

  # All finished, unmount the file-systems
  unmount_upgrade

  echo_log "Upgrade finished!"
  exit 0
fi

OpenPOWER on IntegriCloud