summaryrefslogtreecommitdiffstats
path: root/usr.sbin/mlxcontrol/mlxcontrol.8
blob: 542f9948b4d733fcb1de5c91d2a3410171f15672 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
.\"
.\" Copyright (c) 2000 Michael Smith
.\" All rights reserved.
.\"
.\" Redistribution and use in source and binary forms, with or without
.\" modification, are permitted provided that the following conditions
.\" are met:
.\" 1. Redistributions of source code must retain the above copyright
.\"    notice, this list of conditions and the following disclaimer.
.\" 2. The name of the author may not be used to endorse or promote products
.\"    derived from this software without specific prior written permission
.\"
.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
.\" IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
.\" OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
.\" IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
.\" INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
.\" NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
.\" DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
.\" THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
.\" (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
.\" THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
.\"
.\" $FreeBSD$
.\"
.Dd April 10, 2000
.Dt MLXCONTROL 8
.Os
.Sh NAME
.Nm mlxcontrol
.Nd Mylex DAC-family RAID management utility
.Sh SYNOPSIS
.Nm
.Aq command
.Op args
.Nm
status
.Op Fl qv
.Op Ar drive
.Nm
rescan
.Ar controller
.Op Ar controller ...
.Nm
detach
.Ar drive
.Op Ar drive ...
.Nm
detach
.Fl a
.Nm
check
.Ar drive
.Nm
config
.Ar controller
.Nm
help
.Ar command
.Sh DESCRIPTION
The
.Nm
utility provides status monitoring and management functions
for devices attached
to the
.Xr mlx 4
driver.
.Pp
Controller names are of the form "mlxN"
where N is the unit number of the controller.
Drive names are of the form "mlxdN"
where N is the unit number of the drive.
Do not specify the path to a device node.
.Pp
.Bl -tag -width rebuild
.It status
Print the status of controllers and system drives.
If one or more drives are specified,
only print information about these drives,
otherwise print information
about all controllers and drives in the system.
With the
.Fl v
flag, display much more verbose information.
With the
.Fl q
flag, do not print any output.
This command returns
0 if all drives tested are online,
1 if one or more drives are critical and
2 if one or more are offline.
.It rescan
Rescan one or more controllers for non-attached system drives
(e.g.\& drives that have been
detached or created subsequent to driver initialisation).
If the
.Fl a
flag is supplied, rescan all controllers in the system.
.It detach
Detach one or more system drives.
Drives must be unmounted
and not opened by any other utility for this command to succeed.
If the
.Fl a
flag is supplied, detach all system drives from the nominated controller.
.It check
Initiate a consistency check and repair pass on a redundant system drive
(e.g.\& RAID1 or RAID5).
The controller will scan the system drive and repair any inconsistencies.
This command returns immediately;
use the
.Ar status
command to monitor the progress of the check.
.It rebuild
Requires two arguments,
.Ar controller
and
.Ar physdrive
as specified in the
output of the
.Ar status
command.
All system drives using space on the physical drive
.Ar physdrive
are rebuilt, reconstructing all data on the drive.
Note that each controller can only perform one rebuild at a time.
This command returns immediately; use the
.Ar status
command to monitor the progress of the rebuild.
.It config
Print the current configuration from the nominated controller.
This command will be updated
to allow addition/deletion of system drives from a configuration
in a future release.
.It help
Print usage information for
.Ar command .
.El
.Sh AUTHORS
The mlxcontrol utility was written by
.An Michael Smith
.Aq msmith@FreeBSD.org .
.Sh BUGS
The
.Ar config
command does not yet support modifying system drive configuration.
.Pp
Error log extraction is not yet supported.
OpenPOWER on IntegriCloud