summaryrefslogtreecommitdiffstats
path: root/sbin/camcontrol/camcontrol.8
blob: 653c9bcb31a07158827fb7dfd6d1363806ee722d (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
.\"
.\" Copyright (c) 1998, 1999, 2000, 2002, 2005, 2006, 2007 Kenneth D. Merry.
.\" All rights reserved.
.\"
.\" Redistribution and use in source and binary forms, with or without
.\" modification, are permitted provided that the following conditions
.\" are met:
.\" 1. Redistributions of source code must retain the above copyright
.\"    notice, this list of conditions and the following disclaimer.
.\" 2. Redistributions in binary form must reproduce the above copyright
.\"    notice, this list of conditions and the following disclaimer in the
.\"    documentation and/or other materials provided with the distribution.
.\" 3. The name of the author may not be used to endorse or promote products
.\"    derived from this software without specific prior written permission.
.\"
.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
.\" ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
.\" SUCH DAMAGE.
.\"
.\" $FreeBSD$
.\"
.Dd February 17, 2017
.Dt CAMCONTROL 8
.Os
.Sh NAME
.Nm camcontrol
.Nd CAM control program
.Sh SYNOPSIS
.Nm
.Aq Ar command
.Op device id
.Op generic args
.Op command args
.Nm
.Ic devlist
.Op Fl b
.Op Fl v
.Nm
.Ic periphlist
.Op device id
.Op Fl n Ar dev_name
.Op Fl u Ar unit_number
.Nm
.Ic tur
.Op device id
.Op generic args
.Nm
.Ic inquiry
.Op device id
.Op generic args
.Op Fl D
.Op Fl S
.Op Fl R
.Nm
.Ic identify
.Op device id
.Op generic args
.Op Fl v
.Nm
.Ic reportluns
.Op device id
.Op generic args
.Op Fl c
.Op Fl l
.Op Fl r Ar reporttype
.Nm
.Ic readcap
.Op device id
.Op generic args
.Op Fl b
.Op Fl h
.Op Fl H
.Op Fl N
.Op Fl q
.Op Fl s
.Nm
.Ic start
.Op device id
.Op generic args
.Nm
.Ic stop
.Op device id
.Op generic args
.Nm
.Ic load
.Op device id
.Op generic args
.Nm
.Ic eject
.Op device id
.Op generic args
.Nm
.Ic reprobe
.Op device id
.Nm
.Ic rescan
.Aq all | bus Ns Op :target:lun
.Nm
.Ic reset
.Aq all | bus Ns Op :target:lun
.Nm
.Ic defects
.Op device id
.Op generic args
.Aq Fl f Ar format
.Op Fl P
.Op Fl G
.Op Fl q
.Op Fl s
.Op Fl S Ar offset
.Op Fl X
.Nm
.Ic modepage
.Op device id
.Op generic args
.Aq Fl m Ar page[,subpage] | Fl l
.Op Fl P Ar pgctl
.Op Fl b | Fl e
.Op Fl d
.Nm
.Ic cmd
.Op device id
.Op generic args
.Aq Fl a Ar cmd Op args
.Aq Fl c Ar cmd Op args
.Op Fl d
.Op Fl f
.Op Fl i Ar len Ar fmt
.Bk -words
.Op Fl o Ar len Ar fmt Op args
.Op Fl r Ar fmt
.Ek
.Nm
.Ic smpcmd
.Op device id
.Op generic args
.Aq Fl r Ar len Ar fmt Op args
.Aq Fl R Ar len Ar fmt Op args
.Nm
.Ic smprg
.Op device id
.Op generic args
.Op Fl l
.Nm
.Ic smppc
.Op device id
.Op generic args
.Aq Fl p Ar phy
.Op Fl l
.Op Fl o Ar operation
.Op Fl d Ar name
.Op Fl m Ar rate
.Op Fl M Ar rate
.Op Fl T Ar pp_timeout
.Op Fl a Ar enable|disable
.Op Fl A Ar enable|disable
.Op Fl s Ar enable|disable
.Op Fl S Ar enable|disable
.Nm
.Ic smpphylist
.Op device id
.Op generic args
.Op Fl l
.Op Fl q
.Nm
.Ic smpmaninfo
.Op device id
.Op generic args
.Op Fl l
.Nm
.Ic debug
.Op Fl I
.Op Fl P
.Op Fl T
.Op Fl S
.Op Fl X
.Op Fl c
.Op Fl p
.Aq all|off|bus Ns Op :target Ns Op :lun
.Nm
.Ic tags
.Op device id
.Op generic args
.Op Fl N Ar tags
.Op Fl q
.Op Fl v
.Nm
.Ic negotiate
.Op device id
.Op generic args
.Op Fl c
.Op Fl D Ar enable|disable
.Op Fl M Ar mode
.Op Fl O Ar offset
.Op Fl q
.Op Fl R Ar syncrate
.Op Fl T Ar enable|disable
.Op Fl U
.Op Fl W Ar bus_width
.Op Fl v
.Nm
.Ic format
.Op device id
.Op generic args
.Op Fl q
.Op Fl r
.Op Fl w
.Op Fl y
.Nm
.Ic sanitize
.Op device id
.Op generic args
.Aq Fl a Ar overwrite | block | crypto | exitfailure
.Op Fl c Ar passes
.Op Fl I
.Op Fl P Ar pattern
.Op Fl q
.Op Fl U
.Op Fl r
.Op Fl w
.Op Fl y
.Nm
.Ic idle
.Op device id
.Op generic args
.Op Fl t Ar time
.Nm
.Ic standby
.Op device id
.Op generic args
.Op Fl t Ar time
.Nm
.Ic sleep
.Op device id
.Op generic args
.Nm
.Ic apm
.Op device id
.Op generic args
.Op Fl l Ar level
.Nm
.Ic aam
.Op device id
.Op generic args
.Op Fl l Ar level
.Nm
.Ic fwdownload
.Op device id
.Op generic args
.Aq Fl f Ar fw_image
.Op Fl q
.Op Fl s
.Op Fl y
.Nm
.Ic security
.Op device id
.Op generic args
.Op Fl d Ar pwd
.Op Fl e Ar pwd
.Op Fl f
.Op Fl h Ar pwd
.Op Fl k Ar pwd
.Op Fl l Ar high|maximum
.Op Fl q
.Op Fl s Ar pwd
.Op Fl T Ar timeout
.Op Fl U Ar user|master
.Op Fl y
.Nm
.Ic hpa
.Op device id
.Op generic args
.Op Fl f
.Op Fl l
.Op Fl P
.Op Fl p Ar pwd
.Op Fl q
.Op Fl s Ar max_sectors
.Op Fl U Ar pwd
.Op Fl y
.Nm
.Ic persist
.Op device id
.Op generic args
.Aq Fl i Ar action | Fl o Ar action
.Op Fl a
.Op Fl I Ar trans_id
.Op Fl k Ar key
.Op Fl K Ar sa_key
.Op Fl p
.Op Fl R Ar rel_tgt_port
.Op Fl s Ar scope
.Op Fl S
.Op Fl T Ar res_type
.Op Fl U
.Nm
.Ic attrib
.Op device id
.Op generic args
.Aq Fl r Ar action | Fl w Ar attrib
.Op Fl a Ar attr_num
.Op Fl c
.Op Fl e Ar elem_addr
.Op Fl F Ar form1,form2
.Op Fl p Ar part
.Op Fl s Ar start_addr
.Op Fl T Ar elem_type
.Op Fl V Ar lv_num
.Nm
.Ic opcodes
.Op device id
.Op generic args
.Op Fl o Ar opcode
.Op Fl s Ar service_action
.Op Fl N
.Op Fl T
.Nm
.Ic zone
.Aq Fl c Ar cmd
.Op Fl a
.Op Fl l Ar lba
.Op Fl o Ar rep_opts
.Op Fl P Ar print_opts
.Nm
.Ic epc
.Aq Fl c Ar cmd
.Op Fl d
.Op Fl D
.Op Fl e
.Op Fl H
.Op Fl p Ar power_cond
.Op Fl P
.Op Fl r Ar restore_src
.Op Fl s
.Op Fl S Ar power_src
.Op Fl T Ar timer
.Nm
.Ic timestamp
.Op device id
.Op generic args
.Ao Fl r Oo Ns Fl f Ar format | Fl m | Fl U Oc | Fl s Ao Fl f Ar format Fl T Ar time | Fl U Ac Ac
.Nm
.Ic help
.Sh DESCRIPTION
The
.Nm
utility is designed to provide a way for users to access and control the
.Fx
CAM subsystem.
.Pp
The
.Nm
utility
can cause a loss of data and/or system crashes if used improperly.
Even
expert users are encouraged to exercise caution when using this command.
Novice users should stay away from this utility.
.Pp
The
.Nm
utility has a number of primary functions, many of which support an optional
device identifier.
A device identifier can take one of three forms:
.Bl -tag -width 14n
.It deviceUNIT
Specify a device name and unit number combination, like "da5" or "cd3".
.It bus:target
Specify a bus number and target id.
The bus number can be determined from
the output of
.Dq camcontrol devlist .
The lun defaults to 0.
.It bus:target:lun
Specify the bus, target and lun for a device.
(e.g.\& 1:2:0)
.El
.Pp
The device identifier, if it is specified,
.Em must
come immediately after the function name, and before any generic or
function-specific arguments.
Note that the
.Fl n
and
.Fl u
arguments described below will override any device name or unit number
specified beforehand.
The
.Fl n
and
.Fl u
arguments will
.Em not
override a specified bus:target or bus:target:lun, however.
.Pp
Most of the
.Nm
primary functions support these generic arguments:
.Bl -tag -width 14n
.It Fl C Ar count
SCSI command retry count.
In order for this to work, error recovery
.Pq Fl E
must be turned on.
.It Fl E
Instruct the kernel to perform generic SCSI error recovery for the given
command.
This is needed in order for the retry count
.Pq Fl C
to be honored.
Other than retrying commands, the generic error recovery in
the code will generally attempt to spin up drives that are not spinning.
It may take some other actions, depending upon the sense code returned from
the command.
.It Fl n Ar dev_name
Specify the device type to operate on, e.g.\& "da", "cd".
.It Fl Q Ar task_attr
.Tn SCSI
task attribute for the command, if it is a
.Tn SCSI
command.
This may be ordered, simple, head, or aca.
In most cases this is not needed.
The default is simple, which works with all
.Tn SCSI
devices.
The task attribute may also be specified numerically.
.It Fl t Ar timeout
SCSI command timeout in seconds.
This overrides the default timeout for
any given command.
.It Fl u Ar unit_number
Specify the device unit number, e.g.\& "1", "5".
.It Fl v
Be verbose, print out sense information for failed SCSI commands.
.El
.Pp
Primary command functions:
.Bl -tag -width periphlist
.It Ic devlist
List all physical devices (logical units) attached to the CAM subsystem.
This also includes a list of peripheral drivers attached to each device.
With the
.Fl v
argument, SCSI bus number, adapter name and unit numbers are printed as
well.
On the other hand, with the
.Fl b
argument, only the bus adapter, and unit information will be printed, and
device information will be omitted.
.It Ic periphlist
List all peripheral drivers attached to a given physical device (logical
unit).
.It Ic tur
Send the SCSI test unit ready (0x00) command to the given device.
The
.Nm
utility will report whether the device is ready or not.
.It Ic inquiry
Send a SCSI inquiry command (0x12) to a device.
By default,
.Nm
will print out the standard inquiry data, device serial number, and
transfer rate information.
The user can specify that only certain types of
inquiry data be printed:
.Bl -tag -width 4n
.It Fl D
Get the standard inquiry data.
.It Fl S
Print out the serial number.
If this flag is the only one specified,
.Nm
will not print out "Serial Number" before the value returned by the drive.
This is to aid in script writing.
.It Fl R
Print out transfer rate information.
.El
.It Ic identify
Send a ATA identify command (0xec) to a device.
.It Ic reportluns
Send the SCSI REPORT LUNS (0xA0) command to the given device.
By default,
.Nm
will print out the list of logical units (LUNs) supported by the target device.
There are a couple of options to modify the output:
.Bl -tag -width 14n
.It Fl c
Just print out a count of LUNs, not the actual LUN numbers.
.It Fl l
Just print out the LUNs, and do not print out the count.
.It Fl r Ar reporttype
Specify the type of report to request from the target:
.Bl -tag -width 012345678
.It default
Return the default report.
This is the
.Nm
default.
Most targets will support this report if they support the REPORT LUNS
command.
.It wellknown
Return only well known LUNs.
.It all
Return all available LUNs.
.El
.El
.Pp
.Nm
will try to print out LUN numbers in a reasonable format.
It can understand the peripheral, flat, LUN and extended LUN formats.
.It Ic readcap
Send the SCSI READ CAPACITY command to the given device and display
the results.
If the device is larger than 2TB, the SCSI READ CAPACITY (16) service
action will be sent to obtain the full size of the device.
By default,
.Nm
will print out the last logical block of the device, and the blocksize of
the device in bytes.
To modify the output format, use the following options:
.Bl -tag -width 5n
.It Fl b
Just print out the blocksize, not the last block or device size.
This cannot be used with
.Fl N
or
.Fl s .
.It Fl h
Print out the device size in human readable (base 2, 1K == 1024) format.
This implies
.Fl N
and cannot be used with
.Fl q
or
.Fl b .
.It Fl H
Print out the device size in human readable (base 10, 1K == 1000) format.
.It Fl N
Print out the number of blocks in the device instead of the last logical
block.
.It Fl q
Quiet, print out the numbers only (separated by a comma if
.Fl b
or
.Fl s
are not specified).
.It Fl s
Print out the last logical block or the size of the device only, and omit
the blocksize.
.El
.Pp
Note that this command only displays the information, it does not update
the kernel data structures.
Use the
.Nm 
reprobe subcommand to do that.
.It Ic start
Send the SCSI Start/Stop Unit (0x1B) command to the given device with the
start bit set.
.It Ic stop
Send the SCSI Start/Stop Unit (0x1B) command to the given device with the
start bit cleared.
.It Ic load
Send the SCSI Start/Stop Unit (0x1B) command to the given device with the
start bit set and the load/eject bit set.
.It Ic eject
Send the SCSI Start/Stop Unit (0x1B) command to the given device with the
start bit cleared and the load/eject bit set.
.It Ic rescan
Tell the kernel to scan all busses in the system (with the
.Ar all
argument), the given bus (XPT_SCAN_BUS), or bus:target:lun
(XPT_SCAN_LUN) for new devices or devices that have gone away.
The user
may specify a scan of all busses, a single bus, or a lun.
Scanning all luns
on a target is not supported.
.It Ic reprobe
Tell the kernel to refresh the information about the device and
notify the upper layer,
.Xr GEOM 4 .
This includes sending the SCSI READ CAPACITY command and updating
the disk size visible to the rest of the system.
.It Ic reset
Tell the kernel to reset all busses in the system (with the
.Ar all
argument) or the given bus (XPT_RESET_BUS) by issuing a SCSI bus
reset for that bus, or to reset the given bus:target:lun
(XPT_RESET_DEV), typically by issuing a BUS DEVICE RESET message after
connecting to that device.
Note that this can have a destructive impact
on the system.
.It Ic defects
Send the
.Tn SCSI
READ DEFECT DATA (10) command (0x37) or the
.Tn SCSI
READ DEFECT DATA (12) command (0xB7) to the given device, and
print out any combination of: the total number of defects, the primary
defect list (PLIST), and the grown defect list (GLIST).
.Bl -tag -width 11n
.It Fl f Ar format
Specify the requested format of the defect list.
The format argument is
required.
Most drives support the physical sector format.
Some drives
support the logical block format.
Many drives, if they do not support the
requested format, return the data in an alternate format, along with sense
information indicating that the requested data format is not supported.
The
.Nm
utility
attempts to detect this, and print out whatever format the drive returns.
If the drive uses a non-standard sense code to report that it does not
support the requested format,
.Nm
will probably see the error as a failure to complete the request.
.Pp
The format options are:
.Bl -tag -width 9n
.It block
Print out the list as logical blocks.
This is limited to 32-bit block sizes, and isn't supported by many modern
drives.
.It longblock
Print out the list as logical blocks.
This option uses a 64-bit block size.
.It bfi
Print out the list in bytes from index format.
.It extbfi
Print out the list in extended bytes from index format.
The extended format allows for ranges of blocks to be printed.
.It phys
Print out the list in physical sector format.
Most drives support this format.
.It extphys
Print out the list in extended physical sector format.
The extended format allows for ranges of blocks to be printed.
.El
.It Fl G
Print out the grown defect list.
This is a list of bad blocks that have
been remapped since the disk left the factory.
.It Fl P
Print out the primary defect list.
This is the list of defects that were present in the factory.
.It Fl q
When printing status information with
.Fl s ,
only print the number of defects.
.It Fl s
Just print the number of defects, not the list of defects.
.It Fl S Ar offset
Specify the starting offset into the defect list.
This implies using the
.Tn SCSI
READ DEFECT DATA (12) command, as the 10 byte version of the command
doesn't support the address descriptor index field.
Not all drives support the 12 byte command, and some drives that support
the 12 byte command don't support the address descriptor index field.
.It Fl X
Print out defects in hexadecimal (base 16) form instead of base 10 form.
.El
.Pp
If neither
.Fl P
nor
.Fl G
is specified,
.Nm
will print out the number of defects given in the READ DEFECT DATA header
returned from the drive.
Some drives will report 0 defects if neither the primary or grown defect
lists are requested.
.It Ic modepage
Allows the user to display and optionally edit a SCSI mode page.
The mode
page formats are located in
.Pa /usr/share/misc/scsi_modes .
This can be overridden by specifying a different file in the
.Ev SCSI_MODES
environment variable.
The
.Ic modepage
command takes several arguments:
.Bl -tag -width 12n
.It Fl d
Disable block descriptors for mode sense.
.It Fl b
Displays mode page data in binary format.
.It Fl e
This flag allows the user to edit values in the mode page.
The user may
either edit mode page values with the text editor pointed to by his
.Ev EDITOR
environment variable, or supply mode page values via standard input, using
the same format that
.Nm
uses to display mode page values.
The editor will be invoked if
.Nm
detects that standard input is terminal.
.It Fl l
Lists all available mode pages.
If specified more then once, also lists subpages.
.It Fl m Ar page[,subpage]
This specifies the number of the mode page and optionally subpage the user
would like to view and/or edit.
This argument is mandatory unless
.Fl l
is specified.
.It Fl P Ar pgctl
This allows the user to specify the page control field.
Possible values are:
.Bl -tag -width xxx -compact
.It 0
Current values
.It 1
Changeable values
.It 2
Default values
.It 3
Saved values
.El
.El
.It Ic cmd
Allows the user to send an arbitrary ATA or SCSI CDB to any device.
The
.Ic cmd
function requires the
.Fl c
argument to specify SCSI CDB or the
.Fl a
argument to specify ATA Command Block registers values.
Other arguments are optional, depending on
the command type.
The command and data specification syntax is documented
in
.Xr cam_cdbparse 3 .
NOTE: If the CDB specified causes data to be transferred to or from the
SCSI device in question, you MUST specify either
.Fl i
or
.Fl o .
.Bl -tag -width 17n
.It Fl a Ar cmd Op args
This specifies the content of 12 ATA Command Block registers (command,
features, lba_low, lba_mid, lba_high, device, lba_low_exp, lba_mid_exp.
lba_high_exp, features_exp, sector_count, sector_count_exp).
.It Fl c Ar cmd Op args
This specifies the SCSI CDB.
SCSI CDBs may be 6, 10, 12 or 16 bytes.
.It Fl d
Specifies DMA protocol to be used for ATA command.
.It Fl f
Specifies FPDMA (NCQ) protocol to be used for ATA command.
.It Fl i Ar len Ar fmt
This specifies the amount of data to read, and how it should be displayed.
If the format is
.Sq - ,
.Ar len
bytes of data will be read from the device and written to standard output.
.It Fl o Ar len Ar fmt Op args
This specifies the amount of data to be written to a device, and the data
that is to be written.
If the format is
.Sq - ,
.Ar len
bytes of data will be read from standard input and written to the device.
.It Fl r Ar fmt
This specifies that 11 result ATA Command Block registers should be displayed
(status, error, lba_low, lba_mid, lba_high, device, lba_low_exp, lba_mid_exp,
lba_high_exp, sector_count, sector_count_exp), and how.
If the format is
.Sq - ,
11 result registers will be written to standard output in hex.
.El
.It Ic smpcmd
Allows the user to send an arbitrary Serial
Management Protocol (SMP) command to a device.
The
.Ic smpcmd
function requires the
.Fl r
argument to specify the SMP request to be sent, and the
.Fl R
argument to specify the format of the SMP response.
The syntax for the SMP request and response arguments is documented in
.Xr cam_cdbparse 3 .
.Pp
Note that SAS adapters that support SMP passthrough (at least the currently
known adapters) do not accept CRC bytes from the user in the request and do
not pass CRC bytes back to the user in the response.
Therefore users should not include the CRC bytes in the length of the
request and not expect CRC bytes to be returned in the response.
.Bl -tag -width 17n
.It Fl r Ar len Ar fmt Op args
This specifies the size of the SMP request, without the CRC bytes, and the
SMP request format.
If the format is
.Sq - ,
.Ar len
bytes of data will be read from standard input and written as the SMP
request.
.It Fl R Ar len Ar fmt Op args
This specifies the size of the buffer allocated for the SMP response, and
the SMP response format.
If the format is
.Sq - ,
.Ar len
bytes of data will be allocated for the response and the response will be
written to standard output.
.El
.It Ic smprg
Allows the user to send the Serial Management Protocol (SMP) Report General
command to a device.
.Nm
will display the data returned by the Report General command.
If the SMP target supports the long response format, the additional data
will be requested and displayed automatically.
.Bl -tag -width 8n
.It Fl l
Request the long response format only.
Not all SMP targets support the long response format.
This option causes
.Nm
to skip sending the initial report general request without the long bit set
and only issue a report general request with the long bit set.
.El
.It Ic smppc
Allows the user to issue the Serial Management Protocol (SMP) PHY Control
command to a device.
This function should be used with some caution, as it can render devices
inaccessible, and could potentially cause data corruption as well.
The
.Fl p
argument is required to specify the PHY to operate on.
.Bl -tag -width 17n
.It Fl p Ar phy
Specify the PHY to operate on.
This argument is required.
.It Fl l
Request the long request/response format.
Not all SMP targets support the long response format.
For the PHY Control command, this currently only affects whether the
request length is set to a value other than 0.
.It Fl o Ar operation
Specify a PHY control operation.
Only one
.Fl o
operation may be specified.
The operation may be specified numerically (in decimal, hexadecimal, or octal)
or one of the following operation names may be specified:
.Bl -tag -width 16n
.It nop
No operation.
It is not necessary to specify this argument.
.It linkreset
Send the LINK RESET command to the phy.
.It hardreset
Send the HARD RESET command to the phy.
.It disable
Send the DISABLE command to the phy.
Note that the LINK RESET or HARD RESET commands should re-enable the phy.
.It clearerrlog
Send the CLEAR ERROR LOG command.
This clears the error log counters for the specified phy.
.It clearaffiliation
Send the CLEAR AFFILIATION command.
This clears the affiliation from the STP initiator port with the same SAS
address as the SMP initiator that requests the clear operation.
.It sataportsel
Send the TRANSMIT SATA PORT SELECTION SIGNAL command to the phy.
This will cause a SATA port selector to use the given phy as its active phy
and make the other phy inactive.
.It clearitnl
Send the CLEAR STP I_T NEXUS LOSS command to the PHY.
.It setdevname
Send the SET ATTACHED DEVICE NAME command to the PHY.
This requires the
.Fl d
argument to specify the device name.
.El
.It Fl d Ar name
Specify the attached device name.
This option is needed with the
.Fl o Ar setdevname
phy operation.
The name is a 64-bit number, and can be specified in decimal, hexadecimal
or octal format.
.It Fl m Ar rate
Set the minimum physical link rate for the phy.
This is a numeric argument.
Currently known link rates are:
.Bl -tag -width 5n
.It 0x0
Do not change current value.
.It 0x8
1.5 Gbps
.It 0x9
3 Gbps
.It 0xa
6 Gbps
.El
.Pp
Other values may be specified for newer physical link rates.
.It Fl M Ar rate
Set the maximum physical link rate for the phy.
This is a numeric argument.
See the
.Fl m
argument description for known link rate arguments.
.It Fl T Ar pp_timeout
Set the partial pathway timeout value, in microseconds.
See the
.Tn ANSI
.Tn SAS
Protocol Layer (SPL)
specification for more information on this field.
.It Fl a Ar enable|disable
Enable or disable SATA slumber phy power conditions.
.It Fl A Ar enable|disable
Enable or disable SATA partial power conditions.
.It Fl s Ar enable|disable
Enable or disable SAS slumber phy power conditions.
.It Fl S Ar enable|disable
Enable or disable SAS partial phy power conditions.
.El
.It Ic smpphylist
List phys attached to a SAS expander, the address of the end device
attached to the phy, and the inquiry data for that device and peripheral
devices attached to that device.
The inquiry data and peripheral devices are displayed if available.
.Bl -tag -width 5n
.It Fl l
Turn on the long response format for the underlying SMP commands used for
this command.
.It Fl q
Only print out phys that are attached to a device in the CAM EDT (Existing
Device Table).
.El
.It Ic smpmaninfo
Send the SMP Report Manufacturer Information command to the device and
display the response.
.Bl -tag -width 5n
.It Fl l
Turn on the long response format for the underlying SMP commands used for
this command.
.El
.It Ic debug
Turn on CAM debugging printfs in the kernel.
This requires options CAMDEBUG
in your kernel config file.
WARNING: enabling debugging printfs currently
causes an EXTREME number of kernel printfs.
You may have difficulty
turning off the debugging printfs once they start, since the kernel will be
busy printing messages and unable to service other requests quickly.
The
.Ic debug
function takes a number of arguments:
.Bl -tag -width 18n
.It Fl I
Enable CAM_DEBUG_INFO printfs.
.It Fl P
Enable CAM_DEBUG_PERIPH printfs.
.It Fl T
Enable CAM_DEBUG_TRACE printfs.
.It Fl S
Enable CAM_DEBUG_SUBTRACE printfs.
.It Fl X
Enable CAM_DEBUG_XPT printfs.
.It Fl c
Enable CAM_DEBUG_CDB printfs.
This will cause the kernel to print out the
SCSI CDBs sent to the specified device(s).
.It Fl p
Enable CAM_DEBUG_PROBE printfs.
.It all
Enable debugging for all devices.
.It off
Turn off debugging for all devices
.It bus Ns Op :target Ns Op :lun
Turn on debugging for the given bus, target or lun.
If the lun or target
and lun are not specified, they are wildcarded.
(i.e., just specifying a
bus turns on debugging printfs for all devices on that bus.)
.El
.It Ic tags
Show or set the number of "tagged openings" or simultaneous transactions
we attempt to queue to a particular device.
By default, the
.Ic tags
command, with no command-specific arguments (i.e., only generic arguments)
prints out the "soft" maximum number of transactions that can be queued to
the device in question.
For more detailed information, use the
.Fl v
argument described below.
.Bl -tag -width 7n
.It Fl N Ar tags
Set the number of tags for the given device.
This must be between the
minimum and maximum number set in the kernel quirk table.
The default for
most devices that support tagged queueing is a minimum of 2 and a maximum
of 255.
The minimum and maximum values for a given device may be
determined by using the
.Fl v
switch.
The meaning of the
.Fl v
switch for this
.Nm
subcommand is described below.
.It Fl q
Be quiet, and do not report the number of tags.
This is generally used when
setting the number of tags.
.It Fl v
The verbose flag has special functionality for the
.Em tags
argument.
It causes
.Nm
to print out the tagged queueing related fields of the XPT_GDEV_TYPE CCB:
.Bl -tag -width 13n
.It dev_openings
This is the amount of capacity for transactions queued to a given device.
.It dev_active
This is the number of transactions currently queued to a device.
.It devq_openings
This is the kernel queue space for transactions.
This count usually mirrors
dev_openings except during error recovery operations when
the device queue is frozen (device is not allowed to receive
commands), the number of dev_openings is reduced, or transaction
replay is occurring.
.It devq_queued
This is the number of transactions waiting in the kernel queue for capacity
on the device.
This number is usually zero unless error recovery is in
progress.
.It held
The held count is the number of CCBs held by peripheral drivers that have
either just been completed or are about to be released to the transport
layer for service by a device.
Held CCBs reserve capacity on a given
device.
.It mintags
This is the current "hard" minimum number of transactions that can be
queued to a device at once.
The
.Ar dev_openings
value above cannot go below this number.
The default value for
.Ar mintags
is 2, although it may be set higher or lower for various devices.
.It maxtags
This is the "hard" maximum number of transactions that can be queued to a
device at one time.
The
.Ar dev_openings
value cannot go above this number.
The default value for
.Ar maxtags
is 255, although it may be set higher or lower for various devices.
.El
.El
.It Ic negotiate
Show or negotiate various communication parameters.
Some controllers may
not support setting or changing some of these values.
For instance, the
Adaptec 174x controllers do not support changing a device's sync rate or
offset.
The
.Nm
utility
will not attempt to set the parameter if the controller indicates that it
does not support setting the parameter.
To find out what the controller
supports, use the
.Fl v
flag.
The meaning of the
.Fl v
flag for the
.Ic negotiate
command is described below.
Also, some controller drivers do not support
setting negotiation parameters, even if the underlying controller supports
negotiation changes.
Some controllers, such as the Advansys wide
controllers, support enabling and disabling synchronous negotiation for
a device, but do not support setting the synchronous negotiation rate.
.Bl -tag -width 17n
.It Fl a
Attempt to make the negotiation settings take effect immediately by sending
a Test Unit Ready command to the device.
.It Fl c
Show or set current negotiation settings.
This is the default.
.It Fl D Ar enable|disable
Enable or disable disconnection.
.It Fl M Ar mode
Set ATA mode.
.It Fl O Ar offset
Set the command delay offset.
.It Fl q
Be quiet, do not print anything.
This is generally useful when you want to
set a parameter, but do not want any status information.
.It Fl R Ar syncrate
Change the synchronization rate for a device.
The sync rate is a floating
point value specified in MHz.
So, for instance,
.Sq 20.000
is a legal value, as is
.Sq 20 .
.It Fl T Ar enable|disable
Enable or disable tagged queueing for a device.
.It Fl U
Show or set user negotiation settings.
The default is to show or set
current negotiation settings.
.It Fl v
The verbose switch has special meaning for the
.Ic negotiate
subcommand.
It causes
.Nm
to print out the contents of a Path Inquiry (XPT_PATH_INQ) CCB sent to the
controller driver.
.It Fl W Ar bus_width
Specify the bus width to negotiate with a device.
The bus width is
specified in bits.
The only useful values to specify are 8, 16, and 32
bits.
The controller must support the bus width in question in order for
the setting to take effect.
.El
.Pp
In general, sync rate and offset settings will not take effect for a
device until a command has been sent to the device.
The
.Fl a
switch above will automatically send a Test Unit Ready to the device so
negotiation parameters will take effect.
.It Ic format
Issue the
.Tn SCSI
FORMAT UNIT command to the named device.
.Pp
.Em WARNING! WARNING! WARNING!
.Pp
Low level formatting a disk will destroy ALL data on the disk.
Use
extreme caution when issuing this command.
Many users low-level format
disks that do not really need to be low-level formatted.
There are
relatively few scenarios that call for low-level formatting a disk.
One reason for
low-level formatting a disk is to initialize the disk after changing
its physical sector size.
Another reason for low-level formatting a disk
is to revive the disk if you are getting "medium format corrupted" errors
from the disk in response to read and write requests.
.Pp
Some disks take longer than others to format.
Users should specify a
timeout long enough to allow the format to complete.
The default format
timeout is 3 hours, which should be long enough for most disks.
Some hard
disks will complete a format operation in a very short period of time
(on the order of 5 minutes or less).
This is often because the drive
does not really support the FORMAT UNIT command -- it just accepts the
command, waits a few minutes and then returns it.
.Pp
The
.Sq format
subcommand takes several arguments that modify its default behavior.
The
.Fl q
and
.Fl y
arguments can be useful for scripts.
.Bl -tag -width 6n
.It Fl q
Be quiet, do not print any status messages.
This option will not disable
the questions, however.
To disable questions, use the
.Fl y
argument, below.
.It Fl r
Run in
.Dq report only
mode.
This will report status on a format that is already running on the drive.
.It Fl w
Issue a non-immediate format command.
By default,
.Nm
issues the FORMAT UNIT command with the immediate bit set.
This tells the
device to immediately return the format command, before the format has
actually completed.
Then,
.Nm
gathers
.Tn SCSI
sense information from the device every second to determine how far along
in the format process it is.
If the
.Fl w
argument is specified,
.Nm
will issue a non-immediate format command, and will be unable to print any
information to let the user know what percentage of the disk has been
formatted.
.It Fl y
Do not ask any questions.
By default,
.Nm
will ask the user if he/she really wants to format the disk in question,
and also if the default format command timeout is acceptable.
The user
will not be asked about the timeout if a timeout is specified on the
command line.
.El
.It Ic sanitize
Issue the
.Tn SCSI
SANITIZE command to the named device.
.Pp
.Em WARNING! WARNING! WARNING!
.Pp
ALL data in the cache and on the disk will be destroyed or made inaccessible.
Recovery of the data is not possible.
Use extreme caution when issuing this command.
.Pp
The
.Sq sanitize
subcommand takes several arguments that modify its default behavior.
The
.Fl q
and
.Fl y
arguments can be useful for scripts.
.Bl -tag -width 6n
.It Fl a Ar operation
Specify the sanitize operation to perform.
.Bl -tag -width 16n
.It overwrite
Perform an overwrite operation by writing a user supplied
data pattern to the device one or more times.
The pattern is given by the
.Fl P
argument.
The number of times is given by the
.Fl c
argument.
.It block
Perform a block erase operation.
All the device's blocks are set to a vendor defined
value, typically zero.
.It crypto
Perform a cryptographic erase operation.
The encryption keys are changed to prevent the decryption
of the data.
.It exitfailure
Exits a previously failed sanitize operation.
A failed sanitize operation can only be exited if it was
run in the unrestricted completion mode, as provided by the
.Fl U
argument.
.El
.It Fl c Ar passes
The number of passes when performing an
.Sq overwrite
operation.
Valid values are between 1 and 31.
The default is 1.
.It Fl I
When performing an
.Sq overwrite
operation, the pattern is inverted between consecutive passes.
.It Fl P Ar pattern
Path to the file containing the pattern to use when
performing an
.Sq overwrite
operation.
The pattern is repeated as needed to fill each block.
.It Fl q
Be quiet, do not print any status messages.
This option will not disable
the questions, however.
To disable questions, use the
.Fl y
argument, below.
.It Fl U
Perform the sanitize in the unrestricted completion mode.
If the operation fails, it can later be exited with the
.Sq exitfailure
operation.
.It Fl r
Run in
.Dq report only
mode.
This will report status on a sanitize that is already running on the drive.
.It Fl w
Issue a non-immediate sanitize command.
By default,
.Nm
issues the SANITIZE command with the immediate bit set.
This tells the
device to immediately return the sanitize command, before
the sanitize has actually completed.
Then,
.Nm
gathers
.Tn SCSI
sense information from the device every second to determine how far along
in the sanitize process it is.
If the
.Fl w
argument is specified,
.Nm
will issue a non-immediate sanitize command, and will be unable to print any
information to let the user know what percentage of the disk has been
sanitized.
.It Fl y
Do not ask any questions.
By default,
.Nm
will ask the user if he/she really wants to sanitize the disk in question,
and also if the default sanitize command timeout is acceptable.
The user
will not be asked about the timeout if a timeout is specified on the
command line.
.El
.It Ic idle
Put ATA device into IDLE state.
Optional parameter
.Pq Fl t
specifies automatic standby timer value in seconds.
Value 0 disables timer.
.It Ic standby
Put ATA device into STANDBY state.
Optional parameter
.Pq Fl t
specifies automatic standby timer value in seconds.
Value 0 disables timer.
.It Ic sleep
Put ATA device into SLEEP state.
Note that the only way get device out of
this state may be reset.
.It Ic apm
It optional parameter
.Pq Fl l
specified, enables and sets advanced power management level, where
1 -- minimum power, 127 -- maximum performance with standby,
128 -- minimum power without standby, 254 -- maximum performance.
If not specified -- APM is disabled.
.It Ic aam
It optional parameter
.Pq Fl l
specified, enables and sets automatic acoustic management level, where
1 -- minimum noise, 254 -- maximum performance.
If not specified -- AAM is disabled.
.It Ic security
Update or report security settings, using an ATA identify command (0xec).
By default,
.Nm
will print out the security support and associated settings of the device.
The
.Ic security
command takes several arguments:
.Bl -tag -width 0n
.It Fl d Ar pwd
.Pp
Disable device security using the given password for the selected user according
to the devices configured security level.
.It Fl e Ar pwd
.Pp
Erase the device using the given password for the selected user.
.Pp
.Em WARNING! WARNING! WARNING!
.Pp
Issuing a secure erase will
.Em ERASE ALL
user data on the device and may take several hours to complete.
.Pp
When this command is used against an SSD drive all its cells will be marked as
empty, restoring it to factory default write performance.
For SSD's this action
usually takes just a few seconds.
.It Fl f
.Pp
Freeze the security configuration of the specified device.
.Pp
After command completion any other commands that update the device lock mode
shall be command aborted.
Frozen mode is disabled by power-off or hardware reset.
.It Fl h Ar pwd
.Pp
Enhanced erase the device using the given password for the selected user.
.Pp
.Em WARNING! WARNING! WARNING!
.Pp
Issuing an enhanced secure erase will
.Em ERASE ALL
user data on the device and may take several hours to complete.
.Pp
An enhanced erase writes predetermined data patterns to all user data areas,
all previously written user data shall be overwritten, including sectors that
are no longer in use due to reallocation.
.It Fl k Ar pwd
.Pp
Unlock the device using the given password for the selected user according to
the devices configured security level.
.It Fl l Ar high|maximum
.Pp
Specifies which security level to set when issuing a
.Fl s Ar pwd
command.
The security level determines device behavior when the master
password is used to unlock the device.
When the security level is set to high
the device requires the unlock command and the master password to unlock.
When the security level is set to maximum the device requires a secure erase
with the master password to unlock.
.Pp
This option must be used in conjunction with one of the security action commands.
.Pp
Defaults to
.Em high
.It Fl q
.Pp
Be quiet, do not print any status messages.
This option will not disable the questions, however.
To disable questions, use the
.Fl y
argument, below.
.It Fl s Ar pwd
.Pp
Password the device (enable security) using the given password for the selected
user.
This option can be combined with other options such as
.Fl e Em pwd
.Pp
A master password may be set in a addition to the user password. The purpose of
the master password is to allow an administrator to establish a password that
is kept secret from the user, and which may be used to unlock the device if the
user password is lost.
.Pp
.Em Note:
Setting the master password does not enable device security.
.Pp
If the master password is set and the drive supports a Master Revision Code
feature the Master Password Revision Code will be decremented.
.It Fl T Ar timeout
.Pp
Overrides the default timeout, specified in seconds, used for both
.Fl e
and
.Fl h
this is useful if your system has problems processing long timeouts correctly.
.Pp
Usually the timeout is calculated from the information stored on the drive if
present, otherwise it defaults to 2 hours.
.It Fl U Ar user|master
.Pp
Specifies which user to set / use for the running action command, valid values
are user or master and defaults to master if not set.
.Pp
This option must be used in conjunction with one of the security action commands.
.Pp
Defaults to
.Em master
.It Fl y
.Pp
Confirm yes to dangerous options such as
.Fl e
without prompting for confirmation.
.El
.Pp
If the password specified for any action commands does not match the configured
password for the specified user the command will fail.
.Pp
The password in all cases is limited to 32 characters, longer passwords will
fail.
.It Ic hpa
Update or report Host Protected Area details.
By default
.Nm
will print out the HPA support and associated settings of the device.
The
.Ic hpa
command takes several optional arguments:
.Bl -tag -width 0n
.It Fl f
.Pp
Freeze the HPA configuration of the specified device.
.Pp
After command completion any other commands that update the HPA configuration
shall be command aborted.
Frozen mode is disabled by power-off or hardware reset.
.It Fl l
.Pp
Lock the HPA configuration of the device until a successful call to unlock or
the next power-on reset occurs.
.It Fl P
.Pp
Make the HPA max sectors persist across power-on reset or a hardware reset.
This must be used in combination with
.Fl s Ar max_sectors
.
.It Fl p Ar pwd
.Pp
Set the HPA configuration password required for unlock calls.
.It Fl q
.Pp
Be quiet, do not print any status messages.
This option will not disable the questions.
To disable questions, use the
.Fl y
argument, below.
.It Fl s Ar max_sectors
.Pp
Configures the maximum user accessible sectors of the device.
This will change the number of sectors the device reports.
.Pp
.Em WARNING! WARNING! WARNING!
.Pp
Changing the max sectors of a device using this option will make the data on
the device beyond the specified value inaccessible.
.Pp
Only one successful
.Fl s Ar max_sectors
call can be made without a power-on reset or a hardware reset of the device.
.It Fl U Ar pwd
.Pp
Unlock the HPA configuration of the specified device using the given password.
If the password specified does not match the password configured via
.Fl p Ar pwd
the command will fail.
.Pp
After 5 failed unlock calls, due to password miss-match, the device will refuse
additional unlock calls until after a power-on reset.
.It Fl y
.Pp
Confirm yes to dangerous options such as
.Fl e
without prompting for confirmation
.El
.Pp
The password for all HPA commands is limited to 32 characters, longer passwords
will fail.
.It Ic fwdownload
Program firmware of the named
.Tn SCSI
or ATA device using the image file provided.
.Pp
If the device is a
.Tn SCSI
device and it provides a recommended timeout for the WRITE BUFFER command
(see the
.Nm 
opcodes subcommand), that timeout will be used for the firmware download.
The drive-recommended timeout value may be overridden on the command line
with the
.Fl t
option.
.Pp
Current list of supported vendors for SCSI/SAS drives:
.Bl -tag -width 10n
.It HGST
Tested with 4TB SAS drives, model number HUS724040ALS640.
.It HITACHI
.It HP
.It IBM
Tested with LTO-5 (ULTRIUM-HH5) and LTO-6 (ULTRIUM-HH6) tape drives.
There is a separate table entry for hard drives, because the update method
for hard drives is different than the method for tape drives.
.It PLEXTOR
.It QUALSTAR
.It QUANTUM
.It SAMSUNG
Tested with SM1625 SSDs.
.It SEAGATE
Tested with Constellation ES (ST32000444SS), ES.2 (ST33000651SS) and
ES.3 (ST1000NM0023) drives.
.It SmrtStor
Tested with 400GB Optimus SSDs (TXA2D20400GA6001).
.El
.Pp
.Em WARNING! WARNING! WARNING!
.Pp
Little testing has been done to make sure that different device models from
each vendor work correctly with the fwdownload command.
A vendor name appearing in the supported list means only that firmware of at
least one device type from that vendor has successfully been programmed with
the fwdownload command.
Extra caution should be taken when using this command since there is no
guarantee it will not break a device from the listed vendors.
Ensure that you have a recent backup of the data on the device before
performing a firmware update.
.Pp
Note that unknown
.Tn SCSI
protocol devices will not be programmed, since there is little chance of
the firmware download succeeding.
.Pp
.Nm
will currently attempt a firmware download to any
.Tn ATA
or
.Tn SATA
device, since the standard 
.Tn ATA
DOWNLOAD MICROCODE command may work.
Firmware downloads to
.Tn ATA
and 
.Tn SATA
devices are supported for devices connected
to standard
.Tn ATA
and
.Tn SATA
controllers, and devices connected to SAS controllers
with
.Tn SCSI 
to
.Tn ATA
translation capability.
In the latter case,
.Nm
uses the
.Tn SCSI
.Tn ATA
PASS-THROUGH command to send the 
.Tn ATA
DOWNLOAD MICROCODE command to the drive.
Some
.Tn SCSI
to
.Tn ATA
translation implementations don't work fully when translating
.Tn SCSI
WRITE BUFFER commands to
.Tn ATA
DOWNLOAD MICROCODE commands, but do support
.Tn ATA
passthrough well enough to do a firmware download.
.Bl -tag -width 11n
.It Fl f Ar fw_image
Path to the firmware image file to be downloaded to the specified device.
.It Fl q
Do not print informational messages, only print errors.
This option should be used with the
.Fl y
option to suppress all output.
.It Fl s
Run in simulation mode.
Device checks are run and the confirmation dialog is shown, but no firmware
download will occur.
.It Fl v
Show
.Tn SCSI
or
.Tn ATA
errors in the event of a failure.
.Pp
In simulation mode, print out the
.Tn SCSI
CDB
or
.Tn ATA
register values that would be used for the firmware download command.
.It Fl y
Do not ask for confirmation.
.El
.It Ic persist
Persistent reservation support.
Persistent reservations are a way to reserve a particular
.Tn SCSI
LUN for use by one or more
.Tn SCSI
initiators.
If the
.Fl i
option is specified,
.Nm
will issue the
.Tn SCSI
PERSISTENT RESERVE IN
command using the requested service action.
If the
.Fl o
option is specified,
.Nm
will issue the
.Tn SCSI
PERSISTENT RESERVE OUT
command using the requested service action.
One of those two options is required.
.Pp
Persistent reservations are complex, and fully explaining them is outside
the scope of this manual.
Please visit
http://www.t10.org
and download the latest SPC spec for a full explanation of persistent
reservations.
.Bl -tag -width 8n
.It Fl i Ar mode
Specify the service action for the PERSISTENT RESERVE IN command.
Supported service actions:
.Bl -tag -width 19n
.It read_keys
Report the current persistent reservation generation (PRgeneration) and any
registered keys.
.It read_reservation
Report the persistent reservation, if any.
.It report_capabilities
Report the persistent reservation capabilities of the LUN.
.It read_full_status
Report the full status of persistent reservations on the LUN.
.El
.It Fl o Ar mode
Specify the service action for the PERSISTENT RESERVE OUT command.
For service actions like register that are components of other service
action names, the entire name must be specified.
Otherwise, enough of the service action name must be specified to
distinguish it from other possible service actions.
Supported service actions:
.Bl -tag -width 15n
.It register
Register a reservation key with the LUN or unregister a reservation key.
To register a key, specify the requested key as the Service Action
Reservation Key.
To unregister a key, specify the previously registered key as the
Reservation Key.
To change a key, specify the old key as the Reservation Key and the new
key as the Service Action Reservation Key.
.It register_ignore
This is similar to the register subcommand, except that the Reservation Key
is ignored.
The Service Action Reservation Key will overwrite any previous key
registered for the initiator.
.It reserve
Create a reservation.
A key must be registered with the LUN before the LUN can be reserved, and
it must be specified as the Reservation Key.
The type of reservation must also be specified.
The scope defaults to LUN scope (LU_SCOPE), but may be changed.
.It release
Release a reservation.
The Reservation Key must be specified.
.It clear
Release a reservation and remove all keys from the device.
The Reservation Key must be specified.
.It preempt
Remove a reservation belonging to another initiator.
The Reservation Key must be specified.
The Service Action Reservation Key may be specified, depending on the
operation being performed.
.It preempt_abort
Remove a reservation belonging to another initiator and abort all
outstanding commands from that initiator.
The Reservation Key must be specified.
The Service Action Reservation Key may be specified, depending on the
operation being performed.
.It register_move
Register another initiator with the LUN, and establish a reservation on the
LUN for that initiator.
The Reservation Key and Service Action Reservation Key must be specified.
.It replace_lost
Replace Lost Reservation information.
.El
.It Fl a
Set the All Target Ports (ALL_TG_PT) bit.
This requests that the key registration be applied to all target ports and
not just the particular target port that receives the command.
This only applies to the register and register_ignore actions.
.It Fl I Ar tid
Specify a Transport ID.
This only applies to the Register and Register and Move service actions for
Persistent Reserve Out.
Multiple Transport IDs may be specified with multiple
.Fl I
arguments.
With the Register service action, specifying one or more Transport IDs
implicitly enables the
.Fl S
option which turns on the SPEC_I_PT bit.
Transport IDs generally have the format protocol,id.
.Bl -tag -width 5n
.It SAS
A SAS Transport ID consists of
.Dq sas,
followed by a 64-bit SAS address.
For example:
.Pp
.Dl sas,0x1234567812345678
.It FC
A Fibre Channel Transport ID consists of
.Dq fcp,
followed by a 64-bit Fibre Channel World Wide Name.
For example:
.Pp
.Dl fcp,0x1234567812345678
.It SPI
A Parallel SCSI address consists of
.Dq spi,
followed by a SCSI target ID and a relative target port identifier.
For example:
.Pp
.Dl spi,4,1
.It 1394
An IEEE 1394 (Firewire) Transport ID consists of
.Dq sbp,
followed by a 64-bit EUI-64 IEEE 1394 node unique identifier.
For example:
.Pp
.Dl sbp,0x1234567812345678
.It RDMA
A SCSI over RDMA Transport ID consists of
.Dq srp,
followed by a 128-bit RDMA initiator port identifier.
The port identifier must be exactly 32 or 34 (if the leading 0x is
included) hexadecimal digits.
Only hexadecimal (base 16) numbers are supported.
For example:
.Pp
.Dl srp,0x12345678123456781234567812345678
.It iSCSI
An iSCSI Transport ID consists an iSCSI name and optionally a separator and
iSCSI session ID.
For example, if only the iSCSI name is specified:
.Pp
.Dl iqn.2012-06.com.example:target0
.Pp
If the iSCSI separator and initiator session ID are specified:
.Pp
.Dl iqn.2012-06.com.example:target0,i,0x123
.It PCIe
A SCSI over PCIe Transport ID consists of
.Dq sop,
followed by a PCIe Routing ID.
The Routing ID consists of a bus, device and function or in the alternate
form, a bus and function.
The bus must be in the range of 0 to 255 inclusive and the device must be
in the range of 0 to 31 inclusive.
The function must be in the range of 0 to 7 inclusive if the standard form
is used, and in the range of 0 to 255 inclusive if the alternate form is
used.
For example, if a bus, device and function are specified for the standard
Routing ID form:
.Pp
.Dl sop,4,5,1
.Pp
If the alternate Routing ID form is used:
.Pp
.Dl sop,4,1
.El
.It Fl k Ar key
Specify the Reservation Key.
This may be in decimal, octal or hexadecimal format.
The value is zero by default if not otherwise specified.
The value must be between 0 and 2^64 - 1, inclusive.
.It Fl K Ar key
Specify the Service Action Reservation Key.
This may be in decimal, octal or hexadecimal format.
The value is zero by default if not otherwise specified.
The value must be between 0 and 2^64 - 1, inclusive.
.It Fl p
Enable the Activate Persist Through Power Loss bit.
This is only used for the register and register_ignore actions.
This requests that the reservation persist across power loss events.
.It Fl s Ar scope
Specify the scope of the reservation.
The scope may be specified by name or by number.
The scope is ignored for register, register_ignore and clear.
If the desired scope isn't available by name, you may specify the number.
.Bl -tag -width 7n
.It lun
LUN scope (0x00).
This encompasses the entire LUN.
.It extent
Extent scope (0x01).
.It element
Element scope (0x02).
.El
.It Fl R Ar rtp
Specify the Relative Target Port.
This only applies to the Register and Move service action of the Persistent
Reserve Out command.
.It Fl S
Enable the SPEC_I_PT bit.
This only applies to the Register service action of Persistent Reserve Out.
You must also specify at least one Transport ID with
.Fl I
if this option is set.
If you specify a Transport ID, this option is automatically set.
It is an error to specify this option for any service action other than
Register.
.It Fl T Ar type
Specify the reservation type.
The reservation type may be specified by name or by number.
If the desired reservation type isn't available by name, you may specify
the number.
Supported reservation type names:
.Bl -tag -width 11n
.It read_shared
Read Shared mode.
.It wr_ex
Write Exclusive mode.
May also be specified as
.Dq write_exclusive .
.It rd_ex
Read Exclusive mode.
May also be specified as
.Dq read_exclusive .
.It ex_ac
Exclusive access mode.
May also be specified as
.Dq exclusive_access .
.It wr_ex_ro
Write Exclusive Registrants Only mode.
May also be specified as
.Dq write_exclusive_reg_only .
.It ex_ac_ro
Exclusive Access Registrants Only mode.
May also be specified as
.Dq exclusive_access_reg_only .
.It wr_ex_ar
Write Exclusive All Registrants mode.
May also be specified as
.Dq write_exclusive_all_regs .
.It ex_ac_ar
Exclusive Access All Registrants mode.
May also be specified as
.Dq exclusive_access_all_regs .
.El
.It Fl U
Specify that the target should unregister the initiator that sent
the Register and Move request.
By default, the target will not unregister the initiator that sends the
Register and Move request.
This option only applies to the Register and Move service action of the
Persistent Reserve Out command.
.El
.It Ic attrib
Issue the
.Tn SCSI
READ or WRITE ATTRIBUTE commands.
These commands are used to read and write attributes in Medium Auxiliary
Memory (MAM).
The most common place Medium Auxiliary Memory is found is small flash chips
included tape cartriges.
For instance,
.Tn LTO
tapes have MAM.
Either the
.Fl r 
option or the
.Fl w 
option must be specified.
.Bl -tag -width 14n
.It Fl r Ar action
Specify the READ ATTRIBUTE service action.
.Bl -tag -width 11n
.It attr_values
Issue the ATTRIBUTE VALUES service action.
Read and decode the available attributes and their values.
.It attr_list
Issue the ATTRIBUTE LIST service action.
List the attributes that are available to read and write.
.It lv_list
Issue the LOGICAL VOLUME LIST service action.
List the available logical volumes in the MAM.
.It part_list
Issue the PARTITION LIST service action.
List the available partitions in the MAM.
.It supp_attr
Issue the SUPPORTED ATTRIBUTES service action.
List attributes that are supported for reading or writing.
These attributes may or may not be currently present in the MAM.
.El
.It Fl w Ar attr
Specify an attribute to write to the MAM.
This option is not yet implemented.
.It Fl a Ar num
Specify the attribute number to display.
This option only works with the attr_values, attr_list and supp_attr
arguments to 
.Fl r .
.It Fl c
Display cached attributes.
If the device supports this flag, it allows displaying attributes for the
last piece of media loaded in the drive.
.It Fl e Ar num
Specify the element address.
This is used for specifying which element number in a medium changer to
access when reading attributes.
The element number could be for a picker, portal, slot or drive.
.It Fl F Ar form1,form2
Specify the output format for the attribute values (attr_val) display as a
comma separated list of options.
The default output is currently set to field_all,nonascii_trim,text_raw.
Once this code is ported to FreeBSD 10, any text fields will be converted
from their codeset to the user's native codeset with 
.Xr iconv 3 .
.Pp
The text options are mutually exclusive; if you specify more than one, you
will get unpredictable results.
The nonascii options are also mutually exclusive.
Most of the field options may be logically ORed together.
.Bl -tag -width 12n
.It text_esc
Print text fields with non-ASCII characters escaped.
.It text_raw
Print text fields natively, with no codeset conversion.
.It nonascii_esc
If any non-ASCII characters occur in fields that are supposed to be ASCII,
escape the non-ASCII characters.
.It nonascii_trim
If any non-ASCII characters occur in fields that are supposed to be ASCII,
omit the non-ASCII characters.
.It nonascii_raw
If any non-ASCII characters occur in fields that are supposed to be ASCII,
print them as they are.
.It field_all
Print all of the prefix fields: description, attribute number, attribute
size, and the attribute's readonly status.
If field_all is specified, specifying any other field options will not have
an effect.
.It field_none
Print none of the prefix fields, and only print out the attribute value.
If field_none is specified, specifying any other field options will result
in those fields being printed.
.It field_desc
Print out the attribute description.
.It field_num
Print out the attribute number.
.It field_size
Print out the attribute size.
.It field_rw
Print out the attribute's readonly status.
.El
.It Fl p Ar part
Specify the partition.
When the media has multiple partitions, specifying different partition
numbers allows seeing the values for each individual partition.
.It Fl s Ar start_num
Specify the starting attribute number.
This requests that the target device return attribute information starting
at the given number.
.It Fl T Ar elem_type
Specify the element type.
For medium changer devices, this allows specifying the type the element
referenced in the element address (
.Fl e ) .
Valid types are:
.Dq all ,
.Dq picker ,
.Dq slot ,
.Dq portal ,
and
.Dq drive .
.It Fl V Ar vol_num
Specify the number of the logical volume to operate on.
If the media has multiple logical volumes, this will allow displaying
or writing attributes on the given logical volume.
.El
.It Ic opcodes
Issue the REPORT SUPPORTED OPCODES service action of the
.Tn SCSI
MAINTENANCE IN
command.
Without arguments, this command will return a list of all
.Tn SCSI
commands supported by the device, including service actions of commands
that support service actions.
It will also include the
.Tn SCSI
CDB (Command Data Block) length for each command, and the description of
each command if it is known.
.Bl -tag -width 18n
.It Fl o Ar opcode
Request information on a specific opcode instead of the list of supported
commands.
If supported, the target will return a CDB-like structure that indicates
the opcode, service action (if any), and a mask of bits that are supported
in that CDB.
.It Fl s Ar service_action
For commands that support a service action, specify the service action to
query.
.It Fl N
If a service action is specified for a given opcode, and the device does
not support the given service action, the device should not return a
.Tn SCSI
error, but rather indicate in the returned parameter data that the command
is not supported.
By default, if a service action is specified for an opcode, and service
actions are not supported for the opcode in question, the device will
return an error.
.It Fl T
Include timeout values.
This option works with the default display, which includes all commands
supported by the device, and with the
.Fl o
and
.Fl s
options, which request information on a specific command and service
action.
This requests that the device report Nominal and Recommended timeout values
for the given command or commands.
The timeout values are in seconds.
The timeout descriptor also includes a command-specific 
.El
.It Ic zone
Manage
.Tn SCSI
and
.Tn ATA
Zoned Block devices.
This allows managing devices that conform to the
.Tn SCSI
Zoned Block Commands (ZBC) and
.Tn ATA
Zoned ATA Command Set (ZAC)
specifications.
Devices using these command sets are usually hard drives using Shingled
Magnetic Recording (SMR).
There are three types of SMR drives:
.Bl -tag -width 13n
.It Drive Managed
Drive Managed drives look and act just like a standard random access block
device, but underneath, the drive reads and writes the bulk of its capacity
using SMR zones.
Sequential writes will yield better performance, but writing sequentially
is not required.
.It Host Aware
Host Aware drives expose the underlying zone layout via
.Tn SCSI
or
.Tn ATA
commands and allow the host to manage the zone conditions.
The host is not required to manage the zones on the drive, though.
Sequential writes will yield better performance in Sequential Write
Preferred zones, but the host can write randomly in those zones.
.It Host Managed
Host Managed drives expose the underlying zone layout via
.Tn SCSI
or
.Tn ATA
commands.
The host is required to access the zones according to the rules described
by the zone layout.
Any commands that violate the rules will be returned with an error.
.El
.Pp
SMR drives are divided into zones (typically in the range of 256MB each)
that fall into three general categories:
.Bl -tag -width 20n
.It Conventional
These are also known as Non Write Pointer zones.
These zones can be randomly written without an unexpected performance penalty.
.It Sequential Preferred
These zones should be written sequentially starting at the write pointer
for the zone.
They may be written randomly.
Writes that do not conform to the zone layout may be significantly slower
than expected.
.It Sequential Required
These zones must be written sequentially.
If they are not written sequentially, starting at the write pointer, the
command will fail.
.El
.Pp
.Bl -tag -width 12n
.It Fl c Ar cmd
Specify the zone subcommand:
.Bl -tag -width 6n
.It rz
Issue the Report Zones command.
All zones are returned by default.
Specify report options with
.Fl o
and printing options with
.Fl P .
Specify the starting LBA with
.Fl l .
Note that
.Dq reportzones
is also accepted as a command argument.
.It open
Explicitly open the zone specified by the starting LBA.
.It close
Close the zone specified by starting LBA.
.It finish
Finish the zone specified by the starting LBA.
.It rwp
Reset the write pointer for the zone specified by the starting LBA.
.El
.It Fl a
For the Open, Close, Finish, and Reset Write Pointer operations, apply the
operation to all zones on the drive.
.It Fl l Ar lba
Specify the starting LBA.
For the Report Zones command, this tells the drive to report starting with
the zone that starts at the given LBA.
For the other commands, this allows the user to identify the zone requested
by its starting LBA.
The LBA may be specified in decimal, hexadecimal or octal notation.
.It Fl o Ar rep_opt
For the Report Zones command, specify a subset of zones to report.
.Bl -tag -width 8n
.It all
Report all zones.
This is the default.
.It emtpy
Report only empty zones.
.It imp_open
Report zones that are implicitly open.
This means that the host has sent a write to the zone without explicitly
opening the zone.
.It exp_open
Report zones that are explicitly open.
.It closed
Report zones that have been closed by the host.
.It full
Report zones that are full.
.It ro
Report zones that are in the read only state.
Note that
.Dq readonly
is also accepted as an argument.
.It offline
Report zones that are in the offline state.
.It reset
Report zones where the device recommends resetting write pointers.
.It nonseq
Report zones that have the Non Sequential Resources Active flag set.
These are zones that are Sequential Write Preferred, but have been written
non-sequentially.
.It nonwp
Report Non Write Pointer zones, also known as Conventional zones.
.El
.It Fl P Ar print_opt
Specify a printing option for Report Zones:
.Bl -tag -width 7n
.It normal
Normal Report Zones output.
This is the default.
The summary and column headings are printed, fields are separated by spaces
and the fields themselves may contain spaces.
.It summary
Just print the summary:  the number of zones, the maximum LBA (LBA of the
last logical block on the drive), and the value of the 
.Dq same 
field.
The
.Dq same
field describes whether the zones on the drive are all identical, all
different, or whether they are the same except for the last zone, etc.
.It script
Print the zones in a script friendly format.
The summary and column headings are omitted, the fields are separated by
commas, and the fields do not contain spaces.
The fields contain underscores where spaces would normally be used.
.El
.El
.It Ic epc
Issue
.Tn ATA
Extended Power Conditions (EPC) feature set commands.
This only works on
.Tn ATA
protocol drives, and will not work on
.Tn SCSI
protocol drives.
It will work on
.Tn SATA
drives behind a
.Tn SCSI
to
.Tn ATA
translation layer (SAT).
It may be helpful to read the ATA Command Set - 4 (ACS-4) description of
the Extended Power Conditions feature set, available at t13.org, to
understand the details of this particular 
.Nm
subcommand.
.Bl -tag -width 6n
.It Fl c Ar cmd
Specify the epc subcommand
.Bl -tag -width 7n
.It restore
Restore drive power condition settings.
.Bl -tag -width 6n
.It Fl r Ar src
Specify the source for the restored power settings, either
.Dq default
or
.Dq saved .
This argument is required.
.It Fl s
Save the settings.
This only makes sense to specify when restoring from defaults.
.El
.It goto
Go to the specified power condition.
.Bl -tag -width 7n
.It Fl p Ar cond
Specify the power condition: Idle_a, Idle_b, Idle_c, Standby_y, Standby_z.
This argument is required.
.It Fl D
Specify delayed entry to the power condition.
The drive, if it supports this, can enter the power condition after the
command completes.
.It Fl H
Hold the power condition.
If the drive supports this option, it will hold the power condition and
reject all commands that would normally cause it to exit that power
condition.
.El
.It timer
Set the timer value for a power condition and enable or disable the
condition.
See the
.Dq list
display described below to see what the current timer settings are for each
Idle and Standby mode supported by the drive.
.Bl -tag -width 8n
.It Fl e
Enable the power condition.
One of 
.Fl e
or
.Fl d
is required.
.It Fl d
Disable the power condition.
One of
.Fl d
or
.Fl e
is required.
.It Fl T Ar timer
Specify the timer in seconds.
The user may specify a timer as a floating point number with a maximum
supported resolution of tenths of a second.
Drives may or may not support sub-second timer values.
.It Fl p Ar cond
Specify the power condition: Idle_a, Idle_b, Idle_c, Standby_y, Standby_z.
This argument is required.
.It Fl s
Save the timer and power condition enable/disable state.
By default, if this option is not specified, only the current values for
this power condition will be affected.
.El
.It state
Enable or disable a particular power condition.
.Bl -tag -width 7n
.It Fl e
Enable the power condition.
One of 
.Fl e
or
.Fl d
is required.
.It Fl d
Disable the power condition.
One of
.Fl d
or
.Fl e
is required.
.It Fl p Ar cond
Specify the power condition: Idle_a, Idle_b, Idle_c, Standby_y, Standby_z.
This argument is required.
.It Fl s
Save the power condition enable/disable state.
By default, if this option is not specified, only the current values for
this power condition will be affected.
.El
.It enable
Enable the Extended Power Condition (EPC) feature set.
.It disable
Disable the Extended Power Condition (EPC) feature set.
.It source
Specify the EPC power source.
.Bl -tag -width 6n
.It Fl S Ar src
Specify the power source, either
.Dq battery
or
.Dq nonbattery .
.El
.It status
Get the current status of several parameters related to the Extended Power
Condition (EPC) feature set, including whether APM and EPC are supported
and enabled, whether Low Power Standby is supported, whether setting the
EPC power source is supported, whether Low Power Standby is supported and
the current power condition.
.Bl -tag -width 3n
.It Fl P
Only report the current power condition.
Some drives will exit their current power condition if a command other than
the
.Tn ATA
CHECK POWER MODE command is received.
If this flag is specified,
.Nm
will only issue the
.Tn ATA
CHECK POWER MODE command to the drive.
.El
.It list
Display the
.Tn ATA
Power Conditions log (Log Address 0x08).
This shows the list of Idle and Standby power conditions the drive
supports, and a number of parameters about each condition, including
whether it is enabled and what the timer value is.
.El
.El
.It Ic timestamp
Issue REPORT TIMESTAMP or SET TIMESTAMP
.Tn SCSI
commands. Either the
.Fl r
option or the
.Fl s
option must be specified.
.Bl -tag -width 6n
.It Fl r
Report the device's timestamp.
If no more arguments are specified, the timestamp will be reported using
the national representation of the date and time, followed by the time
zone.
.Bl -tag -width 9n
.It Fl f Ar format
Specify the strftime format string, as documented in strftime(3), to be used
to format the reported timestamp.
.It Fl m
Report the timestamp as milliseconds since the epoch.
.It Fl U
Report the timestamp using the national representation of the date and
time, but override the system time zone and use UTC instead.
.El
.El
.Bl -tag -width 6n
.It Fl s
Set the device's timestamp. Either the
.Fl f
and 
.Fl T
options or the
.Fl U
option must be specified.
.Bl -tag -width 9n
.It Fl f Ar format
Specify the strptime format string, as documented in strptime(3).
The time must also be specified with the
.Fl T 
option.
.It Fl T
Provide the time in the format specified with the
.Fl f
option.
.It Fl U
Set the timestamp to the host system's time in UTC.
.El
.El
.It Ic help
Print out verbose usage information.
.El
.Sh ENVIRONMENT
The
.Ev SCSI_MODES
variable allows the user to specify an alternate mode page format file.
.Pp
The
.Ev EDITOR
variable determines which text editor
.Nm
starts when editing mode pages.
.Sh FILES
.Bl -tag -width /usr/share/misc/scsi_modes -compact
.It Pa /usr/share/misc/scsi_modes
is the SCSI mode format database.
.It Pa /dev/xpt0
is the transport layer device.
.It Pa /dev/pass*
are the CAM application passthrough devices.
.El
.Sh EXAMPLES
.Dl camcontrol eject -n cd -u 1 -v
.Pp
Eject the CD from cd1, and print SCSI sense information if the command
fails.
.Pp
.Dl camcontrol tur da0
.Pp
Send the SCSI test unit ready command to da0.
The
.Nm
utility will report whether the disk is ready, but will not display sense
information if the command fails since the
.Fl v
switch was not specified.
.Bd -literal -offset indent
camcontrol tur da1 -E -C 4 -t 50 -Q head -v
.Ed
.Pp
Send a test unit ready command to da1.
Enable kernel error recovery.
Specify a retry count of 4, and a timeout of 50 seconds.
Enable sense
printing (with the
.Fl v
flag) if the command fails.
Since error recovery is turned on, the
disk will be spun up if it is not currently spinning.
The
.Tn SCSI
task attribute for the command will be set to Head of Queue.
The
.Nm
utility will report whether the disk is ready.
.Bd -literal -offset indent
camcontrol cmd -n cd -u 1 -v -c "3C 00 00 00 00 00 00 00 0e 00" \e
	-i 0xe "s1 i3 i1 i1 i1 i1 i1 i1 i1 i1 i1 i1"
.Ed
.Pp
Issue a READ BUFFER command (0x3C) to cd1.
Display the buffer size of cd1,
and display the first 10 bytes from the cache on cd1.
Display SCSI sense
information if the command fails.
.Bd -literal -offset indent
camcontrol cmd -n cd -u 1 -v -c "3B 00 00 00 00 00 00 00 0e 00" \e
	-o 14 "00 00 00 00 1 2 3 4 5 6 v v v v" 7 8 9 8
.Ed
.Pp
Issue a WRITE BUFFER (0x3B) command to cd1.
Write out 10 bytes of data,
not including the (reserved) 4 byte header.
Print out sense information if
the command fails.
Be very careful with this command, improper use may
cause data corruption.
.Bd -literal -offset indent
camcontrol modepage da3 -m 1 -e -P 3
.Ed
.Pp
Edit mode page 1 (the Read-Write Error Recover page) for da3, and save the
settings on the drive.
Mode page 1 contains a disk drive's auto read and
write reallocation settings, among other things.
.Pp
.Dl camcontrol rescan all
.Pp
Rescan all SCSI busses in the system for devices that have been added,
removed or changed.
.Pp
.Dl camcontrol rescan 0
.Pp
Rescan SCSI bus 0 for devices that have been added, removed or changed.
.Pp
.Dl camcontrol rescan 0:1:0
.Pp
Rescan SCSI bus 0, target 1, lun 0 to see if it has been added, removed, or
changed.
.Pp
.Dl camcontrol tags da5 -N 24
.Pp
Set the number of concurrent transactions for da5 to 24.
.Bd -literal -offset indent
camcontrol negotiate -n da -u 4 -T disable
.Ed
.Pp
Disable tagged queueing for da4.
.Bd -literal -offset indent
camcontrol negotiate -n da -u 3 -R 20.000 -O 15 -a
.Ed
.Pp
Negotiate a sync rate of 20MHz and an offset of 15 with da3.
Then send a
Test Unit Ready command to make the settings take effect.
.Bd -literal -offset indent
camcontrol smpcmd ses0 -v -r 4 "40 0 00 0" -R 1020 "s9 i1"
.Ed
.Pp
Send the SMP REPORT GENERAL command to ses0, and display the number of PHYs
it contains.
Display SMP errors if the command fails.
.Bd -literal -offset indent
camcontrol security ada0
.Ed
.Pp
Report security support and settings for ada0
.Bd -literal -offset indent
camcontrol security ada0 -U user -s MyPass
.Ed
.Pp
Enable security on device ada0 with the password MyPass
.Bd -literal -offset indent
camcontrol security ada0 -U user -e MyPass
.Ed
.Pp
Secure erase ada0 which has had security enabled with user password MyPass
.Pp
.Em WARNING! WARNING! WARNING!
.Pp
This will
.Em ERASE ALL
data from the device, so backup your data before using!
.Pp
This command can be used against an SSD drive to restoring it to
factory default write performance.
.Bd -literal -offset indent
camcontrol hpa ada0
.Ed
.Pp
Report HPA support and settings for ada0 (also reported via
identify).
.Bd -literal -offset indent
camcontrol hpa ada0 -s 10240
.Ed
.Pp
Enables HPA on ada0 setting the maximum reported sectors to 10240.
.Pp
.Em WARNING! WARNING! WARNING!
.Pp
This will
.Em PREVENT ACCESS
to all data on the device beyond this limit until HPA is disabled by setting
HPA to native max sectors of the device, which can only be done after a
power-on or hardware reset!
.Pp
.Em DO NOT
use this on a device which has an active filesystem!
.Bd -literal -offset indent
camcontrol persist da0 -v -i read_keys
.Ed
.Pp
This will read any persistent reservation keys registered with da0, and
display any errors encountered when sending the PERSISTENT RESERVE IN
.Tn SCSI
command.
.Bd -literal -offset indent
camcontrol persist da0 -v -o register -a -K 0x12345678
.Ed
.Pp
This will register the persistent reservation key 0x12345678 with da0,
apply that registration to all ports on da0, and display any errors that
occur when sending the PERSISTENT RESERVE OUT command.
.Bd -literal -offset indent
camcontrol persist da0 -v -o reserve -s lun -k 0x12345678 -T ex_ac
.Ed
.Pp
This will reserve da0 for the exlusive use of the initiator issuing the
command.
The scope of the reservation is the entire LUN.
Any errors sending the PERSISTENT RESERVE OUT command will be displayed.
.Bd -literal -offset indent
camcontrol persist da0 -v -i read_full
.Ed
.Pp
This will display the full status of all reservations on da0 and print out
status if there are any errors.
.Bd -literal -offset indent
camcontrol persist da0 -v -o release -k 0x12345678 -T ex_ac
.Ed
.Pp
This will release a reservation on da0 of the type ex_ac
(Exclusive Access).
The Reservation Key for this registration is 0x12345678.
Any errors that occur will be displayed.
.Bd -literal -offset indent
camcontrol persist da0 -v -o register -K 0x12345678 -S \e
	-I sas,0x1234567812345678 -I sas,0x8765432187654321
.Ed
.Pp
This will register the key 0x12345678 with da0, specifying that it applies
to the SAS initiators with SAS addresses 0x1234567812345678 and
0x8765432187654321.
.Bd -literal -offset indent
camcontrol persist da0 -v -o register_move -k 0x87654321 \e
	-K 0x12345678 -U -p -R 2 -I fcp,0x1234567812345678
.Ed
.Pp
This will move the registration from the current initiator, whose
Registration Key is 0x87654321, to the Fibre Channel initiator with the
Fiber Channel World Wide Node Name 0x1234567812345678.
A new registration key, 0x12345678, will be registered for the initiator
with the Fibre Channel World Wide Node Name 0x1234567812345678, and the
current initiator will be unregistered from the target.
The reservation will be moved to relative target port 2 on the target
device.
The registration will persist across power losses.
.Bd -literal -offset indent
camcontrol attrib sa0 -v -i attr_values -p 1
.Ed
.Pp
This will read and decode the attribute values from partition 1 on the tape
in tape drive sa0, and will display any
.Tn SCSI
errors that result.
.Pp
.Bd -literal -offset indent
camcontrol zone da0 -v -c rz -P summary
.Ed
.Pp
This will request the SMR zone list from disk da0, and print out a
summary of the zone parameters, and display any
.Tn SCSI
or
.Tn ATA
errors that result.
.Pp
.Bd -literal -offset indent
camcontrol zone da0 -v -c rz -o reset
.Ed
.Pp
This will request the list of SMR zones that should have their write
pointer reset from the disk da0, and display any
.Tn SCSI
or
.Tn ATA
errors that result.
.Pp
.Bd -literal -offset indent
camcontrol zone da0 -v -c rwp -l 0x2c80000
.Ed
.Pp
This will issue the Reset Write Pointer command to disk da0 for the zone
that starts at LBA 0x2c80000 and display any
.Tn SCSI
or
.Tn ATA
errors that result.
.Pp
.Bd -literal -offset indent
camcontrol epc ada0 -c timer -T 60.1 -p Idle_a -e -s
.Ed
.Pp
Set the timer for the Idle_a power condition on drive
.Pa ada0
to 60.1 seconds, enable that particular power condition, and save the timer
value and the enabled state of the power condition.
.Pp
.Bd -literal -offset indent
camcontrol epc da4 -c goto -p Standby_z -H
.Ed
.Pp
Tell drive
.Pa da4
to go to the Standby_z power state (which is
the drive's lowest power state) and hold in that state until it is 
explicitly released by another
.Cm goto
command.
.Pp
.Bd -literal -offset indent
camcontrol epc da2 -c status -P
.Ed
.Pp
Report only the power state of
drive
.Pa da2 .
Some drives will power up in response to the commands sent by the 
.Pa status
subcommand, and the
.Fl P
option causes
.Nm
to only send the
.Tn ATA 
CHECK POWER MODE command, which should not trigger a change in the drive's
power state.
.Pp
.Bd -literal -offset indent
camcontrol epc ada0 -c list
.Ed
.Pp
Display the ATA Power Conditions log (Log Address 0x08) for
drive
.Pa ada0 .
.Pp
.Bd -literal -offset indent
camcontrol timestamp sa0 -s -f "%A %c" \e
	-T "Wednesday Wed Oct 26 21:43:57 2016"
.Ed
.Pp
Set the timestamp of drive
.Pa sa0
using a
.Xr strptime 3 
format string followed by a time string
that was created using this format string.
.Sh SEE ALSO
.Xr cam 3 ,
.Xr cam_cdbparse 3 ,
.Xr cam 4 ,
.Xr pass 4 ,
.Xr xpt 4
.Sh HISTORY
The
.Nm
utility first appeared in
.Fx 3.0 .
.Pp
The mode page editing code and arbitrary SCSI command code are based upon
code in the old
.Xr scsi 8
utility and
.Xr scsi 3
library, written by Julian Elischer and Peter Dufault.
The
.Xr scsi 8
program first appeared in
.Bx 386 0.1.2.4 ,
and first appeared in
.Fx
in
.Fx 2.0.5 .
.Sh AUTHORS
.An Kenneth Merry Aq Mt ken@FreeBSD.org
.Sh BUGS
The code that parses the generic command line arguments does not know that
some of the subcommands take multiple arguments.
So if, for instance, you
tried something like this:
.Bd -literal -offset indent
camcontrol cmd -n da -u 1 -c "00 00 00 00 00 v" 0x00 -v
.Ed
.Pp
The sense information from the test unit ready command would not get
printed out, since the first
.Xr getopt 3
call in
.Nm
bails out when it sees the second argument to
.Fl c
(0x00),
above.
Fixing this behavior would take some gross code, or changes to the
.Xr getopt 3
interface.
The best way to circumvent this problem is to always make sure
to specify generic
.Nm
arguments before any command-specific arguments.