summaryrefslogtreecommitdiffstats
path: root/etc/rc.d/mdconfig
blob: 627da8750b24d580795cdd23d1be2194f18d4b06 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
#!/bin/sh
#
# Copyright (c) 2006  The FreeBSD Project
# All rights reserved.
#
# Redistribution and use in source and binary forms, with or without
# modification, are permitted provided that the following conditions
# are met:
# 1. Redistributions of source code must retain the above copyright
#    notice, this list of conditions and the following disclaimer.
# 2. Redistributions in binary form must reproduce the above copyright
#    notice, this list of conditions and the following disclaimer in the
#    documentation and/or other materials provided with the distribution.
#
# THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
# ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
# IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
# ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
# FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
# DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
# OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
# HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
# LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
# OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
# SUCH DAMAGE.
#
# $FreeBSD$
#

# PROVIDE: mdconfig
# REQUIRE: swap root

. /etc/rc.subr

name="mdconfig"
stop_cmd="mdconfig_stop"
start_cmd="mdconfig_start"
start_precmd='[ -n "${_mdconfig_list}" ]'
required_modules="geom_md:g_md"

is_readonly()
{
	local _mp _ret

	_mp=$1
	_ret=`mount | while read _line; do
		case ${_line} in
		*" ${_mp} "*read-only*)
			echo "yes"
			;;

		*)
			;;
		esac;
	done`

	if [ -n "${_ret}" ]; then
		return 0
	else
		return 1
	fi
}

init_variables()
{
	local _i

	_fs=""
	_mp=""
	_dev="/dev/${_md}"
	eval _config=\$mdconfig_${_md}
	eval _newfs=\$mdconfig_${_md}_newfs

	_type=${_config##*-t\ }
	_type=${_type%%\ *}
	if [ -z "${_type}" ]; then
		err 1 "You need to specify \"-t <type>\" in mdconfig_${_md}"
	fi

	if [ "${_type}" = "vnode" ]; then
		_file=${_config##*-f\ }
		_file=${_file%%\ *}
		if [ -z "${_file}" ]; then
			err 2 "You need to specify \"-f <file>\" in mdconfig_${_md} for vnode devices"
		fi
		if [ "${_file}" != "${_file%.uzip}" ]; then
			_dev="/dev/${_md}.uzip"
		fi
		for _i in `df ${_file} 2>/dev/null`; do _fs=${_i}; done
	fi

	# Debugging help.
	debug "${_md} config: ${_config}"
	debug "${_md} type: ${_type}"
	debug "${_md} dev: ${_dev}"
	debug "${_md} file: ${_file}"
	debug "${_md} fs: ${_fs}"
	debug "${_md} newfs flags: ${_newfs}"
}

mdconfig_start()
{
	local _md _mp _config _type _dev _file _fs _newfs _fsck_cmd

	for _md in ${_mdconfig_list}; do
		init_variables ${_md}
		# Create md(4) devices of types swap, malloc and vnode if the
		# file is on the root partition.
		if [ "${_type}" != "vnode" -o "${_fs}" = "/" ]; then
			if [ "${_type}" = "vnode" ]; then
				if is_readonly ${_fs}; then
					warn "${_fs} is mounted read-only, skipping ${_md}."
					continue
				fi
				if [ "${_file}" != "${_file%.uzip}" ]; then
					load_kld -m g_uzip geom_uzip || return 3
					# sleep a bit to allow creation of /dev/mdX.uzip
					sleep 2
				fi
			fi
			if mdconfig -l -u ${_md} >/dev/null 2>&1; then
				err 3 "${_md} already exists"
			fi
			echo "Creating ${_md} device (${_type})."
			if ! mdconfig -a ${_config} -u ${_md}; then
				echo "Creating ${_md} device failed, moving on."
				continue
			fi
			# Skip fsck for uzip devices.
			if [ "${_type}" = "vnode" ]; then
				if [ "${_file}" != "${_file%.uzip}" ]; then
					_fsck_cmd=":"
				elif checkyesno background_fsck; then
					_fsck_cmd="fsck -F"
				else
					_fsck_cmd="fsck"
				fi
				if ! eval ${_fsck_cmd} -p ${_dev} >/dev/null; then
					echo "Fsck failed on ${_dev}, not mounting the filesystem."
					continue

				fi
			else
				newfs ${_newfs} ${_dev} >/dev/null
			fi
			if mount -d ${_dev} 2>&1 >/dev/null; then
				echo "Mounting ${_dev}."
				mount ${_dev}
			fi
		fi
	done
}

mdconfig_stop()
{
	local _md _mp _config _type _dev _file _fs _newfs _i

	for _md in ${_mdconfig_list}; do
		init_variables ${_md}
		if [ "${_type}" != "vnode" -o "${_fs}" = "/" ]; then
			for _i in `df ${_dev} 2>/dev/null`; do _mp=${_i}; done
			if [ -z "${_mp}" -o "${_mp}" != "${_mp%%%}" ]; then
				echo "Device ${_dev} isn't mounted."
			else
				echo "Umounting ${_dev}."
				umount ${_dev}
			fi
			if mdconfig -l -u ${_md} >/dev/null 2>&1; then
				echo "Destroying ${_md}."
				mdconfig -d -u ${_md}
			fi
		fi
	done
}

_mdconfig_cmd="$1"
if [ $# -gt 0 ]; then
        shift
fi
[ -n "$*" ] && _mdconfig_list="$*"

load_rc_config $name

if [ -z "${_mdconfig_list}" ]; then
	for _mdconfig_config in `list_vars mdconfig_md[0-9]\* |
		sort_lite -nk1.12`
	do
		_mdconfig_unit=${_mdconfig_config#mdconfig_md}
		_mdconfig_list="$_mdconfig_list md$_mdconfig_unit"
	done
	_mdconfig_list="${_mdconfig_list# }"
fi

run_rc_command "${_mdconfig_cmd}"
OpenPOWER on IntegriCloud