diff options
author | yongari <yongari@FreeBSD.org> | 2011-11-22 21:22:06 +0000 |
---|---|---|
committer | yongari <yongari@FreeBSD.org> | 2011-11-22 21:22:06 +0000 |
commit | 6479d45e1526c99672febf3a29a6a99305871131 (patch) | |
tree | 9a0356cdb58d0f361410a61e5c9567059472fba0 /sys/dev/fb/vgareg.h | |
parent | a9fce2442e7b7d3ec1b855a6d931142e5371fc98 (diff) | |
download | FreeBSD-src-6479d45e1526c99672febf3a29a6a99305871131.zip FreeBSD-src-6479d45e1526c99672febf3a29a6a99305871131.tar.gz |
For IP1001 PHY, do not set multi-port device(MASTER). Ideally this
bit should not affect link establishment process of auto-negotiation
if manual configuration is not used, which is true in auto-negotiation.
However it seems setting this bit interfere with IP1001 PHY's
down-shifting feature such that establishing a 10/100Mbps link failed
when 1000baseT link is not available during auto-negotiation process.
Tested by: Andrey Smagin <samspeed <> mail dot ru >
Diffstat (limited to 'sys/dev/fb/vgareg.h')