summaryrefslogtreecommitdiffstats
path: root/share
diff options
context:
space:
mode:
authorglebius <glebius@FreeBSD.org>2006-01-27 11:28:32 +0000
committerglebius <glebius@FreeBSD.org>2006-01-27 11:28:32 +0000
commit3e2163d390b67c40b3006ccd57aa2c5fb3dfeb37 (patch)
treee70d05fcdb822967f3cbb278f3a8b530e092099d /share
parent4b80a65bfea74b0e795656c25215544a0193413d (diff)
downloadFreeBSD-src-3e2163d390b67c40b3006ccd57aa2c5fb3dfeb37.zip
FreeBSD-src-3e2163d390b67c40b3006ccd57aa2c5fb3dfeb37.tar.gz
Update NGM_PPPOE_GETMODE and NGM_PPPOE_SETMODE descriptions, since
new D-Link compat mode is introduced.
Diffstat (limited to 'share')
-rw-r--r--share/man/man4/ng_pppoe.442
1 files changed, 30 insertions, 12 deletions
diff --git a/share/man/man4/ng_pppoe.4 b/share/man/man4/ng_pppoe.4
index 01d2d75..bb0aaab 100644
--- a/share/man/man4/ng_pppoe.4
+++ b/share/man/man4/ng_pppoe.4
@@ -35,7 +35,7 @@
.\" $FreeBSD$
.\" $Whistle: ng_pppoe.8,v 1.1 1999/01/25 23:46:27 archie Exp $
.\"
-.Dd July 5, 2005
+.Dd January 27, 2006
.Dt NG_PPPOE 4
.Os
.Sh NAME
@@ -182,24 +182,42 @@ struct ngpppoe_sts {
.Ed
.Bl -tag -width 3n
.It Dv NGM_PPPOE_GETMODE
-The
-.Nm
-node can operate in two different modes:
-standard mode described in RFC 2516, and in a non-standard mode compatible
-with equipment from 3Com.
+This command returns the current compatibility mode of the node
+as a string.
+.Tn ASCII
+form of this message is
+.Qq Li pppoe_getmode .
+The following keywords are can be returned:
+.Bl -tag -width 3n
+.It Qq standard
+The node operates according to RFC 2516.
+.It Qq 3Com
When
.Nm
-is a client node, it initiates a session using the configured mode.
+is a PPPoE client, it initiates a session encapsulating packets into
+incorrect 3Com ethertypes.
+This compatibility option doesn't affect server mode.
In server mode
.Nm
-supports both modes simultaneously.
-This message returns the currently configured mode as a string.
-.Tn ASCII
-form of this message is
-.Qq Li pppoe_getmode .
+supports both modes simultaneously, depending on the ethertype, the
+client used when connecting.
+.It Qq D-Link
+When
+.Nm
+is a PPPoE server serving only specific Service-Name(s), it will respond
+to a PADI requests with empty Service-Name tag, returning all available
+Service-Name(s) on node.
+This option is necessary for compatibility with D-Link DI-614+ and DI-624+
+SOHO routers as clients, when serving only specific Service-Name.
+This compatibility option doesn't affect client mode.
+.El
+.Pp
.It Dv NGM_PPPOE_SETMODE
Configure node to the specified mode.
The string argument is required.
+This command understands same keywords, that are returned by
+.Dv NGM_PPPOE_GETMODE
+command.
.Tn ASCII
form of this message is
.Qq Li pppoe_setmode .
OpenPOWER on IntegriCloud