summaryrefslogtreecommitdiffstats
path: root/share/man/man4/lm75.4
diff options
context:
space:
mode:
authorbrueffer <brueffer@FreeBSD.org>2014-05-11 10:06:27 +0000
committerbrueffer <brueffer@FreeBSD.org>2014-05-11 10:06:27 +0000
commit8e56ee9c85ef48c55f77dfa3b6603ea9737a9033 (patch)
tree909a93939fb85c90107839331a38022728f30f0a /share/man/man4/lm75.4
parent8c8970bc55a46ae36a3e11f2fc502f6ebc544bc1 (diff)
downloadFreeBSD-src-8e56ee9c85ef48c55f77dfa3b6603ea9737a9033.zip
FreeBSD-src-8e56ee9c85ef48c55f77dfa3b6603ea9737a9033.tar.gz
Typo fixes and some language/punctuation improvements.
Diffstat (limited to 'share/man/man4/lm75.4')
-rw-r--r--share/man/man4/lm75.424
1 files changed, 12 insertions, 12 deletions
diff --git a/share/man/man4/lm75.4 b/share/man/man4/lm75.4
index 361044b..8e794dc 100644
--- a/share/man/man4/lm75.4
+++ b/share/man/man4/lm75.4
@@ -24,7 +24,7 @@
.\"
.\" $FreeBSD$
.\"
-.Dd March 7, 2014
+.Dd May 11, 2014
.Dt LM75 4
.Os
.Sh NAME
@@ -69,28 +69,28 @@ dev.lm75.0.shutdown: 0
Is the read-only value of the current temperature read by the sensor.
.It Va dev.lm75.%d.thyst
Sets the hysteresis temperature.
-Once the temperature get over the overtemperature shutdown value (tos)
-it need to drop bellow the hysteresis temperature to disable the output
+Once the temperature gets over the overtemperature shutdown value (tos)
+it needs to drop below the hysteresis temperature to disable the output
(interrupt) pin again.
.It Va dev.lm75.%d.tos
Sets the overtemperature shutdown value.
-Once the temperature get over this value the output pin will be enabled.
+Once the temperature gets over this value the output pin will be enabled.
The way the output (interrupt) pin works, depends on the mode configuration.
.It Va dev.lm75.%d.faults
Is the number of faults that must occur consecutively to activate the
interrupt (output) pin.
It can be set to 1, 2, 4, and 6.
.It Va dev.lm75.%d.mode
-Set the operation mode for the sensor interrupt pin.
+Sets the operation mode for the sensor interrupt pin.
It can be set to 'comparator' (default) or 'interrupt'.
.It Va dev.lm75.%d.polarity
-Set the polarity of the sensor interrupt pin.
+Sets the polarity of the sensor interrupt pin.
It can be set to 'active-low' (default) or 'active-high'.
Please note that the output pin is an open-drain output and it needs a
proper pull-up resistor to work.
.It Va dev.lm75.%d.shutdown
-When set to '1' it shutdown the sensor.
-The temperature convertion stops but the sensor remains with its i2c bus
+When set to '1' it shuts down the sensor.
+The temperature conversion stops but the sensor remains with its i2c bus
active, i.e., it can be woken up by setting this option to '0' again.
.El
.Pp
@@ -124,7 +124,7 @@ On a
.Xr device.hints 5
based system, like
.Li MIPS ,
-these values are configurable for the
+these values are configurable for
.Nm :
.Bl -tag -width ".Va hint.lm75.%d.addr"
.It Va hint.lm75.%d.at
@@ -168,7 +168,7 @@ property indicates which i2c address the
.Nm
is wired at.
.Nm
-temperature sensors can be wired to 8 different address, allowing up to 8
+temperature sensors can be wired to 8 different addresses, allowing up to 8
sensors on the same
.Xr iicbus 4 .
.El
@@ -187,5 +187,5 @@ driver first appeared in
.An -nosplit
The
.Nm
-driver and this manual page was written by
-.An Luiz Otavio O Souza Aq loos@FreeBSD.org
+driver and this manual page were written by
+.An Luiz Otavio O Souza Aq loos@FreeBSD.org .
OpenPOWER on IntegriCloud