summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorian <ian@FreeBSD.org>2016-01-14 19:33:13 +0000
committerian <ian@FreeBSD.org>2016-01-14 19:33:13 +0000
commita925f8a783384b55b73280bc25f5b1037209ab2e (patch)
tree5ba8280cee6f73bcb27c57bc6084e1d9c4c4781a
parentda6ebcec56e8c16bdaa7a1370ce225626b981437 (diff)
downloadFreeBSD-src-a925f8a783384b55b73280bc25f5b1037209ab2e.zip
FreeBSD-src-a925f8a783384b55b73280bc25f5b1037209ab2e.tar.gz
Fix the handling of the "PDC write transfer length" erratum for at91. The
problem affects revision 1xx hardware as well as later versions. Also, the recommended workaround is to set the PDC count register for a 12-byte transfer when the actual size is less than that, but there is no need to extend or zero-out the data buffer, because the blklen register contains the real transfer size and only that many bytes will be transferred. Also add a sysctl to turn debugging printfs on or off on the fly.
-rw-r--r--sys/arm/at91/at91_mci.c21
1 files changed, 10 insertions, 11 deletions
diff --git a/sys/arm/at91/at91_mci.c b/sys/arm/at91/at91_mci.c
index 8e55e02..5bab815 100644
--- a/sys/arm/at91/at91_mci.c
+++ b/sys/arm/at91/at91_mci.c
@@ -446,6 +446,9 @@ at91_mci_attach(device_t dev)
CTLFLAG_RW, &sc->allow_overclock, 0,
"Allow up to 30MHz clock for 25MHz request when next highest speed 15MHz or less.");
+ SYSCTL_ADD_UINT(sctx, SYSCTL_CHILDREN(soid), OID_AUTO, "debug",
+ CTLFLAG_RWTUN, &mci_debug, 0, "enable debug output");
+
/*
* Our real min freq is master_clock/512, but upper driver layers are
* going to set the min speed during card discovery, and the right speed
@@ -783,15 +786,6 @@ at91_mci_start_cmd(struct at91_mci_softc *sc, struct mmc_command *cmd)
WR4(sc, PDC_PTCR, PDC_PTCR_RXTEN);
} else {
len = min(BBSIZE, remaining);
- /*
- * If this is MCI1 revision 2xx controller, apply
- * a work-around for the "Data Write Operation and
- * number of bytes" erratum.
- */
- if ((sc->sc_cap & CAP_MCI1_REV2XX) && len < 12) {
- len = 12;
- memset(sc->bbuf_vaddr[0], 0, 12);
- }
at91_bswap_buf(sc, sc->bbuf_vaddr[0], data->data, len);
err = bus_dmamap_load(sc->dmatag, sc->bbuf_map[0],
sc->bbuf_vaddr[0], len, at91_mci_getaddr,
@@ -800,8 +794,13 @@ at91_mci_start_cmd(struct at91_mci_softc *sc, struct mmc_command *cmd)
panic("IO write dmamap_load failed\n");
bus_dmamap_sync(sc->dmatag, sc->bbuf_map[0],
BUS_DMASYNC_PREWRITE);
+ /*
+ * Erratum workaround: PDC transfer length on a write
+ * must not be smaller than 12 bytes (3 words); only
+ * blklen bytes (set above) are actually transferred.
+ */
WR4(sc, PDC_TPR,paddr);
- WR4(sc, PDC_TCR, len / 4);
+ WR4(sc, PDC_TCR, (len < 12) ? 3 : len / 4);
sc->bbuf_len[0] = len;
remaining -= len;
if (remaining == 0) {
@@ -818,7 +817,7 @@ at91_mci_start_cmd(struct at91_mci_softc *sc, struct mmc_command *cmd)
bus_dmamap_sync(sc->dmatag, sc->bbuf_map[1],
BUS_DMASYNC_PREWRITE);
WR4(sc, PDC_TNPR, paddr);
- WR4(sc, PDC_TNCR, len / 4);
+ WR4(sc, PDC_TNCR, (len < 12) ? 3 : len / 4);
sc->bbuf_len[1] = len;
remaining -= len;
}
OpenPOWER on IntegriCloud