summaryrefslogtreecommitdiffstats
path: root/usr/sbin/pc-sysinstall/backend/functions-unmount.sh
blob: dda328fb17a0ce21a3314bdf56d50e96609a00da (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
#!/bin/sh
#-
# Copyright (c) 2010 iXsystems, Inc.  All rights reserved.
#
# Redistribution and use in source and binary forms, with or without
# modification, are permitted provided that the following conditions
# are met:
# 1. Redistributions of source code must retain the above copyright
#    notice, this list of conditions and the following disclaimer.
# 2. Redistributions in binary form must reproduce the above copyright
#    notice, this list of conditions and the following disclaimer in the
#    documentation and/or other materials provided with the distribution.
#
# THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
# ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
# IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
# ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
# FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
# DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
# OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
# HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
# LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
# OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
# SUCH DAMAGE.
#
# $FreeBSD: src/usr.sbin/pc-sysinstall/backend/functions-unmount.sh,v 1.2 2010/06/27 16:46:11 imp Exp $

# Functions which unmount all mounted disk filesystems

# Unmount all mounted partitions under specified dir
umount_all_dir() {
  	_udir="$1"
	_umntdirs=`mount | sort -r | grep "on $_udir" | cut -d ' ' -f 3`
	for _ud in $_umntdirs
	do
		umount -f ${_ud} 
	done
}

# Script that adds our gmirror devices for syncing
start_gmirror_sync()
{

 cd ${MIRRORCFGDIR}
  for DISK in `ls *`
  do
    MIRRORDISK="`cat ${DISK} | cut -d ':' -f 1`"
    MIRRORBAL="`cat ${DISK} | cut -d ':' -f 2`"
    MIRRORNAME="`cat ${DISK} | cut -d ':' -f 3`"
   
    # Start the mirroring service
    rc_halt "gmirror insert ${MIRRORNAME} /dev/${MIRRORDISK}"

  done

};

# Unmounts all our mounted file-systems
unmount_all_filesystems()
{
   # Copy the logfile to disk before we unmount
   cp ${LOGOUT} ${FSMNT}/root/pc-sysinstall.log
   cd /

   # Start by unmounting any ZFS partitions
   zfs_cleanup_unmount

   # Lets read our partition list, and unmount each
   ##################################################################
   for PART in `ls ${PARTDIR}`
   do
     
     PARTFS="`cat ${PARTDIR}/${PART} | cut -d ':' -f 1`"
     PARTMNT="`cat ${PARTDIR}/${PART} | cut -d ':' -f 2`"
     PARTENC="`cat ${PARTDIR}/${PART} | cut -d ':' -f 3`"
     PARTLABEL="`cat ${PARTDIR}/${PART} | cut -d ':' -f 4`"

     if [ "${PARTENC}" = "ON" ]
     then
       EXT=".eli"
     else
       EXT=""
     fi

     #if [ "${PARTFS}" = "SWAP" ]
     #then
     #  rc_nohalt "swapoff /dev/${PART}${EXT}"
     #fi

     # Check if we've found "/", and unmount that last
     if [ "$PARTMNT" != "/" -a "${PARTMNT}" != "none" -a "${PARTFS}" != "ZFS" ]
     then
       #rc_halt "umount -f /dev/${PART}${EXT}"

       # Re-check if we are missing a label for this device and create it again if so
       if [ ! -e "/dev/label/${PARTLABEL}" ]
       then
         case ${PARTFS} in
             UFS) glabel label ${PARTLABEL} /dev/${PART}${EXT} ;;
           UFS+S) glabel label ${PARTLABEL} /dev/${PART}${EXT} ;;
           UFS+J) glabel label ${PARTLABEL} /dev/${PART}${EXT}.journal ;;
               *) ;;
         esac 
       fi
     fi

     # Check if we've found "/" and make sure the label exists
     if [ "$PARTMNT" = "/" -a "${PARTFS}" != "ZFS" ]
     then
       if [ ! -e "/dev/label/${PARTLABEL}" ]
       then
         case ${PARTFS} in
             UFS) ROOTRELABEL="glabel label ${PARTLABEL} /dev/${PART}${EXT}" ;;
           UFS+S) ROOTRELABEL="glabel label ${PARTLABEL} /dev/${PART}${EXT}" ;;
           UFS+J) ROOTRELABEL="glabel label ${PARTLABEL} /dev/${PART}${EXT}.journal" ;;
               *) ;;
         esac 
       fi
     fi
   done

   # Last lets the /mnt partition
   #########################################################
   #rc_nohalt "umount -f ${FSMNT}"

    # If are using a ZFS on "/" set it to legacy
   if [ ! -z "${FOUNDZFSROOT}" ]
   then
     rc_halt "zfs set mountpoint=legacy ${FOUNDZFSROOT}"
   fi

   # If we need to relabel "/" do it now
   if [ ! -z "${ROOTRELABEL}" ]
   then
     ${ROOTRELABEL}
   fi

   # Unmount our CDMNT
   #rc_nohalt "umount -f ${CDMNT}" >/dev/null 2>/dev/null

   # Check if we need to run any gmirror syncing
   ls ${MIRRORCFGDIR}/* >/dev/null 2>/dev/null
   if [ "$?" = "0" ]
   then
     # Lets start syncing now
     start_gmirror_sync
   fi

};

# Unmounts any filesystems after a failure
unmount_all_filesystems_failure()
{
  cd /

  # if we did a fresh install, start unmounting
  if [ "${INSTALLMODE}" = "fresh" ]
  then

    # Lets read our partition list, and unmount each
    ##################################################################
    if [ -d "${PARTDIR}" ]
    then
    for PART in `ls ${PARTDIR}`
    do
     
       PARTFS="`cat ${PARTDIR}/${PART} | cut -d ':' -f 1`"
       PARTMNT="`cat ${PARTDIR}/${PART} | cut -d ':' -f 2`"
       PARTENC="`cat ${PARTDIR}/${PART} | cut -d ':' -f 3`"

       #if [ "${PARTFS}" = "SWAP" ]
       #then
       #  if [ "${PARTENC}" = "ON" ]
       #  then
       #    rc_nohalt "swapoff /dev/${PART}.eli"
       #  else
       #    rc_nohalt "swapoff /dev/${PART}"
       #  fi
       #fi

       # Check if we've found "/" again, don't need to mount it twice
       if [ "$PARTMNT" != "/" -a "${PARTMNT}" != "none" -a "${PARTFS}" != "ZFS" ]
       then
         #rc_nohalt "umount -f /dev/${PART}"
         #rc_nohalt "umount -f ${FSMNT}${PARTMNT}"
       fi
     done

     # Last lets the /mnt partition
     #########################################################
     #rc_nohalt "umount -f ${FSMNT}"

    fi
   else
     # We are doing a upgrade, try unmounting any of these filesystems
     chroot ${FSMNT} /sbin/umount -a >>${LOGOUT} >>${LOGOUT}
     umount -f ${FSMNT}/usr >>${LOGOUT} 2>>${LOGOUT}
     umount -f ${FSMNT}/dev >>${LOGOUT} 2>>${LOGOUT}
     umount -f ${FSMNT} >>${LOGOUT} 2>>${LOGOUT}
     rc_nohalt "sh ${TMPDIR}/.upgrade-unmount"
   fi
   
   # Unmount our CDMNT
   #rc_nohalt "umount ${CDMNT}"

};
OpenPOWER on IntegriCloud