summaryrefslogtreecommitdiffstats
path: root/PCBSD/pc-sysinstall/backend/parseconfig.sh
diff options
context:
space:
mode:
Diffstat (limited to 'PCBSD/pc-sysinstall/backend/parseconfig.sh')
-rwxr-xr-xPCBSD/pc-sysinstall/backend/parseconfig.sh138
1 files changed, 0 insertions, 138 deletions
diff --git a/PCBSD/pc-sysinstall/backend/parseconfig.sh b/PCBSD/pc-sysinstall/backend/parseconfig.sh
deleted file mode 100755
index a86d583..0000000
--- a/PCBSD/pc-sysinstall/backend/parseconfig.sh
+++ /dev/null
@@ -1,138 +0,0 @@
-#!/bin/sh
-# Main install configuration parsing script
-#
-
-# Source our functions scripts
-. ${BACKEND}/functions.sh
-. ${BACKEND}/functions-bsdlabel.sh
-. ${BACKEND}/functions-cleanup.sh
-. ${BACKEND}/functions-disk.sh
-. ${BACKEND}/functions-extractimage.sh
-. ${BACKEND}/functions-installcomponents.sh
-. ${BACKEND}/functions-localize.sh
-. ${BACKEND}/functions-mountdisk.sh
-. ${BACKEND}/functions-networking.sh
-. ${BACKEND}/functions-newfs.sh
-. ${BACKEND}/functions-parse.sh
-. ${BACKEND}/functions-runcommands.sh
-. ${BACKEND}/functions-unmount.sh
-. ${BACKEND}/functions-upgrade.sh
-. ${BACKEND}/functions-users.sh
-
-# Check that the config file exists
-if [ ! -e "${1}" ]
-then
- echo "ERROR: Install configuration $1 does not exist!"
- exit 1
-fi
-
-# Set our config file variable
-CFGF="$1"
-
-# Check the dirname of the provided CFGF and make sure its a full path
-DIR="`dirname ${CFGF}`"
-if [ "${DIR}" = "." ]
-then
- CFGF="`pwd`/${CFGF}"
-fi
-export CFGF
-
-# Start by doing a sanity check, which will catch any obvious mistakes in the config
-file_sanity_check "installMode disk0 partition bootManager installType installMedium packageType"
-
-# We passed the Sanity check, lets grab some of the universal config settings and store them
-check_value installMode "fresh upgrade"
-check_value bootManager "bsd none"
-check_value installType "PCBSD FreeBSD"
-check_value installMedium "dvd usb ftp rsync LiveCD"
-check_value packageType "uzip tar rsync split cpdup"
-check_value partition "all ALL s1 s2 s3 s4 free FREE"
-if_check_value_exists mirrorbal "load prefer round-robin split"
-
-# We passed all sanity checks! Yay, lets start the install
-echo "File Sanity Check -> OK"
-
-# Lets load the various universal settings now
-get_value_from_cfg installMode
-INSTALLMODE="${VAL}" ; export INSTALLMODE
-
-get_value_from_cfg installType
-INSTALLTYPE="${VAL}" ; export INSTALLTYPE
-
-get_value_from_cfg installMedium
-INSTALLMEDIUM="${VAL}" ; export INSTALLMEDIUM
-
-get_value_from_cfg packageType
-PACKAGETYPE="${VAL}" ; export PACKAGETYPE
-
-# Check if we are doing any networking setup
-start_networking
-
-# If we are not doing an upgrade, lets go ahead and setup the disk
-if [ "${INSTALLMODE}" = "fresh" ]
-then
-
- # Lets start setting up the disk slices now
- setup_disk_slice
-
- # Disk setup complete, now lets parse WORKINGSLICES and setup the bsdlabels
- setup_disk_label
-
- # Now we've setup the bsdlabels, lets go ahead and run newfs / zfs
- # to setup the filesystems
- setup_filesystems
-
- # Lets mount the partitions now
- mount_all_filesystems
-
- # We are ready to begin extraction, lets start now
- init_extraction
-
- # Check if we have any optional modules to load
- install_components
-
- # Do any localization in configuration
- run_localize
-
- # Save any networking config on the installed system
- save_networking_install
-
- # Now add any users
- setup_users
-
- # Now run any commands specified
- run_commands
-
- # Do any last cleanup / setup before unmounting
- run_final_cleanup
-
- # Unmount and finish up
- unmount_all_filesystems
-
- echo_log "Installation finished!"
- exit 0
-
-else
- # We're going to do an upgrade, skip all the disk setup
- # and start by mounting the target drive/slices
- mount_upgrade
-
- # Start the extraction process
- init_extraction
-
- # Do any localization in configuration
- run_localize
-
- # Now run any commands specified
- run_commands
-
- # Merge any old configuration files
- merge_old_configs
-
- # All finished, unmount the file-systems
- unmount_upgrade
-
- echo_log "Upgrade finished!"
- exit 0
-fi
-
OpenPOWER on IntegriCloud