summaryrefslogtreecommitdiffstats
path: root/PCBSD/pc-sysinstall/backend/parseconfig.sh
diff options
context:
space:
mode:
Diffstat (limited to 'PCBSD/pc-sysinstall/backend/parseconfig.sh')
-rwxr-xr-xPCBSD/pc-sysinstall/backend/parseconfig.sh138
1 files changed, 138 insertions, 0 deletions
diff --git a/PCBSD/pc-sysinstall/backend/parseconfig.sh b/PCBSD/pc-sysinstall/backend/parseconfig.sh
new file mode 100755
index 0000000..9bf92b8
--- /dev/null
+++ b/PCBSD/pc-sysinstall/backend/parseconfig.sh
@@ -0,0 +1,138 @@
+#!/bin/sh
+# Main install configuration parsing script
+#
+
+# Source our functions scripts
+. ${BACKEND}/functions.sh
+. ${BACKEND}/functions-bsdlabel.sh
+. ${BACKEND}/functions-cleanup.sh
+. ${BACKEND}/functions-disk.sh
+. ${BACKEND}/functions-extractimage.sh
+. ${BACKEND}/functions-installcomponents.sh
+. ${BACKEND}/functions-localize.sh
+. ${BACKEND}/functions-mountdisk.sh
+. ${BACKEND}/functions-networking.sh
+. ${BACKEND}/functions-newfs.sh
+. ${BACKEND}/functions-parse.sh
+. ${BACKEND}/functions-runcommands.sh
+. ${BACKEND}/functions-unmount.sh
+. ${BACKEND}/functions-upgrade.sh
+. ${BACKEND}/functions-users.sh
+
+# Check that the config file exists
+if [ ! -e "${1}" ]
+then
+ echo "ERROR: Install configuration $1 does not exist!"
+ exit 1
+fi
+
+# Set our config file variable
+CFGF="$1"
+
+# Check the dirname of the provided CFGF and make sure its a full path
+DIR="`dirname ${CFGF}`"
+if [ "${DIR}" = "." ]
+then
+ CFGF="`pwd`/${CFGF}"
+fi
+export CFGF
+
+# Start by doing a sanity check, which will catch any obvious mistakes in the config
+file_sanity_check "installMode disk0 partition bootManager installType installMedium packageType"
+
+# We passed the Sanity check, lets grab some of the universal config settings and store them
+check_value installMode "fresh upgrade"
+check_value bootManager "bsd none"
+check_value installType "PCBSD FreeBSD"
+check_value installMedium "dvd usb ftp rsync"
+check_value packageType "uzip tar rsync split"
+check_value partition "all ALL s1 s2 s3 s4 free FREE"
+if_check_value_exists mirrorbal "load prefer round-robin split"
+
+# We passed all sanity checks! Yay, lets start the install
+echo "File Sanity Check -> OK"
+
+# Lets load the various universal settings now
+get_value_from_cfg installMode
+INSTALLMODE="${VAL}" ; export INSTALLMODE
+
+get_value_from_cfg installType
+INSTALLTYPE="${VAL}" ; export INSTALLTYPE
+
+get_value_from_cfg installMedium
+INSTALLMEDIUM="${VAL}" ; export INSTALLMEDIUM
+
+get_value_from_cfg packageType
+PACKAGETYPE="${VAL}" ; export PACKAGETYPE
+
+# Check if we are doing any networking setup
+start_networking
+
+# If we are not doing an upgrade, lets go ahead and setup the disk
+if [ "${INSTALLMODE}" = "fresh" ]
+then
+
+ # Lets start setting up the disk slices now
+ setup_disk_slice
+
+ # Disk setup complete, now lets parse WORKINGSLICES and setup the bsdlabels
+ setup_disk_label
+
+ # Now we've setup the bsdlabels, lets go ahead and run newfs / zfs
+ # to setup the filesystems
+ setup_filesystems
+
+ # Lets mount the partitions now
+ mount_all_filesystems
+
+ # We are ready to begin extraction, lets start now
+ init_extraction
+
+ # Check if we have any optional modules to load
+ install_components
+
+ # Do any localization in configuration
+ run_localize
+
+ # Save any networking config on the installed system
+ save_networking_install
+
+ # Now add any users
+ setup_users
+
+ # Now run any commands specified
+ run_commands
+
+ # Do any last cleanup / setup before unmounting
+ run_final_cleanup
+
+ # Unmount and finish up
+ unmount_all_filesystems
+
+ echo_log "Installation finished!"
+ exit 0
+
+else
+ # We're going to do an upgrade, skip all the disk setup
+ # and start by mounting the target drive/slices
+ mount_upgrade
+
+ # Start the extraction process
+ init_extraction
+
+ # Do any localization in configuration
+ run_localize
+
+ # Now run any commands specified
+ run_commands
+
+ # Merge any old configuration files
+ merge_old_configs
+
+ # All finished, unmount the file-systems
+ unmount_upgrade
+
+ echo_log "Upgrade finished!"
+ exit 0
+fi
+