summaryrefslogtreecommitdiffstats
path: root/arch/x86/pci/mrst.c
blob: 140942f66b314dbdf6907b7314ee4016751da528 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
/*
 * Moorestown PCI support
 *   Copyright (c) 2008 Intel Corporation
 *     Jesse Barnes <jesse.barnes@intel.com>
 *
 * Moorestown has an interesting PCI implementation:
 *   - configuration space is memory mapped (as defined by MCFG)
 *   - Lincroft devices also have a real, type 1 configuration space
 *   - Early Lincroft silicon has a type 1 access bug that will cause
 *     a hang if non-existent devices are accessed
 *   - some devices have the "fixed BAR" capability, which means
 *     they can't be relocated or modified; check for that during
 *     BAR sizing
 *
 * So, we use the MCFG space for all reads and writes, but also send
 * Lincroft writes to type 1 space.  But only read/write if the device
 * actually exists, otherwise return all 1s for reads and bit bucket
 * the writes.
 */

#include <linux/sched.h>
#include <linux/pci.h>
#include <linux/ioport.h>
#include <linux/init.h>
#include <linux/dmi.h>

#include <asm/acpi.h>
#include <asm/segment.h>
#include <asm/io.h>
#include <asm/smp.h>
#include <asm/pci_x86.h>
#include <asm/hw_irq.h>
#include <asm/io_apic.h>

#define PCIE_CAP_OFFSET	0x100

/* Fixed BAR fields */
#define PCIE_VNDR_CAP_ID_FIXED_BAR 0x00	/* Fixed BAR (TBD) */
#define PCI_FIXED_BAR_0_SIZE	0x04
#define PCI_FIXED_BAR_1_SIZE	0x08
#define PCI_FIXED_BAR_2_SIZE	0x0c
#define PCI_FIXED_BAR_3_SIZE	0x10
#define PCI_FIXED_BAR_4_SIZE	0x14
#define PCI_FIXED_BAR_5_SIZE	0x1c

static int pci_soc_mode = 0;

/**
 * fixed_bar_cap - return the offset of the fixed BAR cap if found
 * @bus: PCI bus
 * @devfn: device in question
 *
 * Look for the fixed BAR cap on @bus and @devfn, returning its offset
 * if found or 0 otherwise.
 */
static int fixed_bar_cap(struct pci_bus *bus, unsigned int devfn)
{
	int pos;
	u32 pcie_cap = 0, cap_data;

	pos = PCIE_CAP_OFFSET;

	if (!raw_pci_ext_ops)
		return 0;

	while (pos) {
		if (raw_pci_ext_ops->read(pci_domain_nr(bus), bus->number,
					  devfn, pos, 4, &pcie_cap))
			return 0;

		if (PCI_EXT_CAP_ID(pcie_cap) == 0x0000 ||
			PCI_EXT_CAP_ID(pcie_cap) == 0xffff)
			break;

		if (PCI_EXT_CAP_ID(pcie_cap) == PCI_EXT_CAP_ID_VNDR) {
			raw_pci_ext_ops->read(pci_domain_nr(bus), bus->number,
					      devfn, pos + 4, 4, &cap_data);
			if ((cap_data & 0xffff) == PCIE_VNDR_CAP_ID_FIXED_BAR)
				return pos;
		}

		pos = PCI_EXT_CAP_NEXT(pcie_cap);
	}

	return 0;
}

static int pci_device_update_fixed(struct pci_bus *bus, unsigned int devfn,
				   int reg, int len, u32 val, int offset)
{
	u32 size;
	unsigned int domain, busnum;
	int bar = (reg - PCI_BASE_ADDRESS_0) >> 2;

	domain = pci_domain_nr(bus);
	busnum = bus->number;

	if (val == ~0 && len == 4) {
		unsigned long decode;

		raw_pci_ext_ops->read(domain, busnum, devfn,
			       offset + 8 + (bar * 4), 4, &size);

		/* Turn the size into a decode pattern for the sizing code */
		if (size) {
			decode = size - 1;
			decode |= decode >> 1;
			decode |= decode >> 2;
			decode |= decode >> 4;
			decode |= decode >> 8;
			decode |= decode >> 16;
			decode++;
			decode = ~(decode - 1);
		} else {
			decode = 0;
		}

		/*
		 * If val is all ones, the core code is trying to size the reg,
		 * so update the mmconfig space with the real size.
		 *
		 * Note: this assumes the fixed size we got is a power of two.
		 */
		return raw_pci_ext_ops->write(domain, busnum, devfn, reg, 4,
				       decode);
	}

	/* This is some other kind of BAR write, so just do it. */
	return raw_pci_ext_ops->write(domain, busnum, devfn, reg, len, val);
}

/**
 * type1_access_ok - check whether to use type 1
 * @bus: bus number
 * @devfn: device & function in question
 *
 * If the bus is on a Lincroft chip and it exists, or is not on a Lincroft at
 * all, the we can go ahead with any reads & writes.  If it's on a Lincroft,
 * but doesn't exist, avoid the access altogether to keep the chip from
 * hanging.
 */
static bool type1_access_ok(unsigned int bus, unsigned int devfn, int reg)
{
	/* This is a workaround for A0 LNC bug where PCI status register does
	 * not have new CAP bit set. can not be written by SW either.
	 *
	 * PCI header type in real LNC indicates a single function device, this
	 * will prevent probing other devices under the same function in PCI
	 * shim. Therefore, use the header type in shim instead.
	 */
	if (reg >= 0x100 || reg == PCI_STATUS || reg == PCI_HEADER_TYPE)
		return 0;
	if (bus == 0 && (devfn == PCI_DEVFN(2, 0)
				|| devfn == PCI_DEVFN(0, 0)
				|| devfn == PCI_DEVFN(3, 0)))
		return 1;
	return 0; /* langwell on others */
}

static int pci_read(struct pci_bus *bus, unsigned int devfn, int where,
		    int size, u32 *value)
{
	if (type1_access_ok(bus->number, devfn, where))
		return pci_direct_conf1.read(pci_domain_nr(bus), bus->number,
					devfn, where, size, value);
	return raw_pci_ext_ops->read(pci_domain_nr(bus), bus->number,
			      devfn, where, size, value);
}

static int pci_write(struct pci_bus *bus, unsigned int devfn, int where,
		     int size, u32 value)
{
	int offset;

	/* On MRST, there is no PCI ROM BAR, this will cause a subsequent read
	 * to ROM BAR return 0 then being ignored.
	 */
	if (where == PCI_ROM_ADDRESS)
		return 0;

	/*
	 * Devices with fixed BARs need special handling:
	 *   - BAR sizing code will save, write ~0, read size, restore
	 *   - so writes to fixed BARs need special handling
	 *   - other writes to fixed BAR devices should go through mmconfig
	 */
	offset = fixed_bar_cap(bus, devfn);
	if (offset &&
	    (where >= PCI_BASE_ADDRESS_0 && where <= PCI_BASE_ADDRESS_5)) {
		return pci_device_update_fixed(bus, devfn, where, size, value,
					       offset);
	}

	/*
	 * On Moorestown update both real & mmconfig space
	 * Note: early Lincroft silicon can't handle type 1 accesses to
	 *       non-existent devices, so just eat the write in that case.
	 */
	if (type1_access_ok(bus->number, devfn, where))
		return pci_direct_conf1.write(pci_domain_nr(bus), bus->number,
					      devfn, where, size, value);
	return raw_pci_ext_ops->write(pci_domain_nr(bus), bus->number, devfn,
			       where, size, value);
}

static int mrst_pci_irq_enable(struct pci_dev *dev)
{
	u8 pin;
	struct io_apic_irq_attr irq_attr;

	pci_read_config_byte(dev, PCI_INTERRUPT_PIN, &pin);

	/* MRST only have IOAPIC, the PCI irq lines are 1:1 mapped to
	 * IOAPIC RTE entries, so we just enable RTE for the device.
	 */
	irq_attr.ioapic = mp_find_ioapic(dev->irq);
	irq_attr.ioapic_pin = dev->irq;
	irq_attr.trigger = 1; /* level */
	irq_attr.polarity = 1; /* active low */
	io_apic_set_pci_routing(&dev->dev, dev->irq, &irq_attr);

	return 0;
}

struct pci_ops pci_mrst_ops = {
	.read = pci_read,
	.write = pci_write,
};

/**
 * pci_mrst_init - installs pci_mrst_ops
 *
 * Moorestown has an interesting PCI implementation (see above).
 * Called when the early platform detection installs it.
 */
int __init pci_mrst_init(void)
{
	printk(KERN_INFO "Intel MID platform detected, using MID PCI ops\n");
	pci_mmcfg_late_init();
	pcibios_enable_irq = mrst_pci_irq_enable;
	pci_root_ops = pci_mrst_ops;
	pci_soc_mode = 1;
	/* Continue with standard init */
	return 1;
}

/* Langwell devices are not true pci devices, they are not subject to 10 ms
 * d3 to d0 delay required by pci spec.
 */
static void __devinit pci_d3delay_fixup(struct pci_dev *dev)
{
	/* PCI fixups are effectively decided compile time. If we have a dual
	   SoC/non-SoC kernel we don't want to mangle d3 on non SoC devices */
        if (!pci_soc_mode)
            return;
	/* true pci devices in lincroft should allow type 1 access, the rest
	 * are langwell fake pci devices.
	 */
	if (type1_access_ok(dev->bus->number, dev->devfn, PCI_DEVICE_ID))
		return;
	dev->d3_delay = 0;
}
DECLARE_PCI_FIXUP_FINAL(PCI_VENDOR_ID_INTEL, PCI_ANY_ID, pci_d3delay_fixup);

static void __devinit mrst_power_off_unused_dev(struct pci_dev *dev)
{
	pci_set_power_state(dev, PCI_D3cold);
}
DECLARE_PCI_FIXUP_FINAL(PCI_VENDOR_ID_INTEL, 0x0801, mrst_power_off_unused_dev);
DECLARE_PCI_FIXUP_FINAL(PCI_VENDOR_ID_INTEL, 0x0809, mrst_power_off_unused_dev);
DECLARE_PCI_FIXUP_FINAL(PCI_VENDOR_ID_INTEL, 0x080C, mrst_power_off_unused_dev);
DECLARE_PCI_FIXUP_FINAL(PCI_VENDOR_ID_INTEL, 0x0812, mrst_power_off_unused_dev);
DECLARE_PCI_FIXUP_FINAL(PCI_VENDOR_ID_INTEL, 0x0815, mrst_power_off_unused_dev);

/*
 * Langwell devices reside at fixed offsets, don't try to move them.
 */
static void __devinit pci_fixed_bar_fixup(struct pci_dev *dev)
{
	unsigned long offset;
	u32 size;
	int i;

	if (!pci_soc_mode)
		return;

	/* Must have extended configuration space */
	if (dev->cfg_size < PCIE_CAP_OFFSET + 4)
		return;

	/* Fixup the BAR sizes for fixed BAR devices and make them unmoveable */
	offset = fixed_bar_cap(dev->bus, dev->devfn);
	if (!offset || PCI_DEVFN(2, 0) == dev->devfn ||
	    PCI_DEVFN(2, 2) == dev->devfn)
		return;

	for (i = 0; i < PCI_ROM_RESOURCE; i++) {
		pci_read_config_dword(dev, offset + 8 + (i * 4), &size);
		dev->resource[i].end = dev->resource[i].start + size - 1;
		dev->resource[i].flags |= IORESOURCE_PCI_FIXED;
	}
}
DECLARE_PCI_FIXUP_HEADER(PCI_VENDOR_ID_INTEL, PCI_ANY_ID, pci_fixed_bar_fixup);
OpenPOWER on IntegriCloud