From 7575983c577c724425d11361acb1fc45834633f3 Mon Sep 17 00:00:00 2001 From: Bartlomiej Zolnierkiewicz Date: Thu, 13 Nov 2014 16:01:25 +0100 Subject: thermal: exynos: remove test_mux pdata field Replace pdata->test_mux check in get_con_reg() by explicitly checking for SoC type. Also since the used pdata->test_mux value is always identical use it directly and remove pdata->test_mux completely. There should be no functional changes caused by this patch. Cc: Amit Daniel Kachhap Cc: Lukasz Majewski Cc: Eduardo Valentin Cc: Zhang Rui Signed-off-by: Bartlomiej Zolnierkiewicz Acked-by: Kyungmin Park Tested-by: Lukasz Majewski Signed-off-by: Eduardo Valentin --- drivers/thermal/samsung/exynos_tmu.c | 5 +++-- drivers/thermal/samsung/exynos_tmu.h | 2 -- drivers/thermal/samsung/exynos_tmu_data.c | 2 -- 3 files changed, 3 insertions(+), 6 deletions(-) (limited to 'drivers/thermal') diff --git a/drivers/thermal/samsung/exynos_tmu.c b/drivers/thermal/samsung/exynos_tmu.c index 65eeecc..2fcb4cd 100644 --- a/drivers/thermal/samsung/exynos_tmu.c +++ b/drivers/thermal/samsung/exynos_tmu.c @@ -193,8 +193,9 @@ static u32 get_con_reg(struct exynos_tmu_data *data, u32 con) { struct exynos_tmu_platform_data *pdata = data->pdata; - if (pdata->test_mux) - con |= (pdata->test_mux << EXYNOS4412_MUX_ADDR_SHIFT); + if (data->soc == SOC_ARCH_EXYNOS4412 || + data->soc == SOC_ARCH_EXYNOS3250) + con |= (EXYNOS4412_MUX_ADDR_VALUE << EXYNOS4412_MUX_ADDR_SHIFT); con &= ~(EXYNOS_TMU_REF_VOLTAGE_MASK << EXYNOS_TMU_REF_VOLTAGE_SHIFT); con |= pdata->reference_voltage << EXYNOS_TMU_REF_VOLTAGE_SHIFT; diff --git a/drivers/thermal/samsung/exynos_tmu.h b/drivers/thermal/samsung/exynos_tmu.h index 2eb4cb9..8de0f82 100644 --- a/drivers/thermal/samsung/exynos_tmu.h +++ b/drivers/thermal/samsung/exynos_tmu.h @@ -89,7 +89,6 @@ enum soc_type { * @first_point_trim: temp value of the first point trimming * @second_point_trim: temp value of the second point trimming * @default_temp_offset: default temperature offset in case of no trimming - * @test_mux; information if SoC supports test MUX * @cal_type: calibration type for temperature * @freq_clip_table: Table representing frequency reduction percentage. * @freq_tab_count: Count of the above table as frequency reduction may @@ -115,7 +114,6 @@ struct exynos_tmu_platform_data { u8 first_point_trim; u8 second_point_trim; u8 default_temp_offset; - u8 test_mux; enum calibration_type cal_type; enum soc_type type; diff --git a/drivers/thermal/samsung/exynos_tmu_data.c b/drivers/thermal/samsung/exynos_tmu_data.c index d90b050..708c3e1 100644 --- a/drivers/thermal/samsung/exynos_tmu_data.c +++ b/drivers/thermal/samsung/exynos_tmu_data.c @@ -109,7 +109,6 @@ struct exynos_tmu_init_data const exynos3250_default_tmu_data = { { EXYNOS3250_TMU_DATA, .type = SOC_ARCH_EXYNOS3250, - .test_mux = EXYNOS4412_MUX_ADDR_VALUE, }, }, .tmu_count = 1, @@ -160,7 +159,6 @@ struct exynos_tmu_init_data const exynos4412_default_tmu_data = { { EXYNOS4412_TMU_DATA, .type = SOC_ARCH_EXYNOS4412, - .test_mux = EXYNOS4412_MUX_ADDR_VALUE, }, }, .tmu_count = 1, -- cgit v1.1