From 820eac0ef8b86f7275acd1f8bccfb0b30f17bbe9 Mon Sep 17 00:00:00 2001 From: Hans Verkuil Date: Mon, 18 Mar 2013 13:20:00 -0300 Subject: [media] DocBook media: fix syntax problems in dvbproperty.xml Caught by xmllint. Signed-off-by: Hans Verkuil Signed-off-by: Mauro Carvalho Chehab --- Documentation/DocBook/media/dvb/dvbproperty.xml | 46 ++++++++++++------------- 1 file changed, 22 insertions(+), 24 deletions(-) (limited to 'Documentation/DocBook') diff --git a/Documentation/DocBook/media/dvb/dvbproperty.xml b/Documentation/DocBook/media/dvb/dvbproperty.xml index 31dc4df..a9b15e3 100644 --- a/Documentation/DocBook/media/dvb/dvbproperty.xml +++ b/Documentation/DocBook/media/dvb/dvbproperty.xml @@ -903,14 +903,12 @@ enum fe_interleaving { svalue is for signed values of the measure (dB measures) and uvalue is for unsigned values (counters, relative scale) scale - Scale for the value. It can be: -
- + FE_SCALE_NOT_AVAILABLE - The parameter is supported by the frontend, but it was not possible to collect it (could be a transitory or permanent condition) FE_SCALE_DECIBEL - parameter is a signed value, measured in 1/1000 dB FE_SCALE_RELATIVE - parameter is a unsigned value, where 0 means 0% and 65535 means 100%. FE_SCALE_COUNTER - parameter is a unsigned value that counts the occurrence of an event, like bit error, block error, or lapsed time. -
@@ -918,9 +916,9 @@ enum fe_interleaving { Indicates the signal strength level at the analog part of the tuner or of the demod. Possible scales for this metric are: - FE_SCALE_NOT_AVAILABLE - it failed to measure it, or the measurement was not complete yet. - FE_SCALE_DECIBEL - signal strength is in 0.0001 dBm units, power measured in miliwatts. This value is generally negative. - FE_SCALE_RELATIVE - The frontend provides a 0% to 100% measurement for power (actually, 0 to 65535). + FE_SCALE_NOT_AVAILABLE - it failed to measure it, or the measurement was not complete yet. + FE_SCALE_DECIBEL - signal strength is in 0.0001 dBm units, power measured in miliwatts. This value is generally negative. + FE_SCALE_RELATIVE - The frontend provides a 0% to 100% measurement for power (actually, 0 to 65535).
@@ -928,9 +926,9 @@ enum fe_interleaving { Indicates the Signal to Noise ratio for the main carrier. Possible scales for this metric are: - FE_SCALE_NOT_AVAILABLE - it failed to measure it, or the measurement was not complete yet. - FE_SCALE_DECIBEL - Signal/Noise ratio is in 0.0001 dB units. - FE_SCALE_RELATIVE - The frontend provides a 0% to 100% measurement for Signal/Noise (actually, 0 to 65535). + FE_SCALE_NOT_AVAILABLE - it failed to measure it, or the measurement was not complete yet. + FE_SCALE_DECIBEL - Signal/Noise ratio is in 0.0001 dB units. + FE_SCALE_RELATIVE - The frontend provides a 0% to 100% measurement for Signal/Noise (actually, 0 to 65535).
@@ -943,8 +941,8 @@ enum fe_interleaving { The frontend may reset it when a channel/transponder is tuned. Possible scales for this metric are: - FE_SCALE_NOT_AVAILABLE - it failed to measure it, or the measurement was not complete yet. - FE_SCALE_COUNTER - Number of error bits counted before the inner coding. + FE_SCALE_NOT_AVAILABLE - it failed to measure it, or the measurement was not complete yet. + FE_SCALE_COUNTER - Number of error bits counted before the inner coding.
@@ -957,9 +955,9 @@ enum fe_interleaving { The frontend may reset it when a channel/transponder is tuned. Possible scales for this metric are: - FE_SCALE_NOT_AVAILABLE - it failed to measure it, or the measurement was not complete yet. - FE_SCALE_COUNTER - Number of bits counted while measuring - DTV_STAT_PRE_ERROR_BIT_COUNT. + FE_SCALE_NOT_AVAILABLE - it failed to measure it, or the measurement was not complete yet. + FE_SCALE_COUNTER - Number of bits counted while measuring + DTV_STAT_PRE_ERROR_BIT_COUNT.
@@ -972,8 +970,8 @@ enum fe_interleaving { The frontend may reset it when a channel/transponder is tuned. Possible scales for this metric are: - FE_SCALE_NOT_AVAILABLE - it failed to measure it, or the measurement was not complete yet. - FE_SCALE_COUNTER - Number of error bits counted after the inner coding. + FE_SCALE_NOT_AVAILABLE - it failed to measure it, or the measurement was not complete yet. + FE_SCALE_COUNTER - Number of error bits counted after the inner coding.
@@ -986,9 +984,9 @@ enum fe_interleaving { The frontend may reset it when a channel/transponder is tuned. Possible scales for this metric are: - FE_SCALE_NOT_AVAILABLE - it failed to measure it, or the measurement was not complete yet. - FE_SCALE_COUNTER - Number of bits counted while measuring - DTV_STAT_POST_ERROR_BIT_COUNT. + FE_SCALE_NOT_AVAILABLE - it failed to measure it, or the measurement was not complete yet. + FE_SCALE_COUNTER - Number of bits counted while measuring + DTV_STAT_POST_ERROR_BIT_COUNT.
@@ -998,8 +996,8 @@ enum fe_interleaving { The frontend may reset it when a channel/transponder is tuned. Possible scales for this metric are: - FE_SCALE_NOT_AVAILABLE - it failed to measure it, or the measurement was not complete yet. - FE_SCALE_COUNTER - Number of error blocks counted after the outer coding. + FE_SCALE_NOT_AVAILABLE - it failed to measure it, or the measurement was not complete yet. + FE_SCALE_COUNTER - Number of error blocks counted after the outer coding.
@@ -1011,9 +1009,9 @@ enum fe_interleaving { by DTV-STAT-TOTAL-BLOCK-COUNT. Possible scales for this metric are: - FE_SCALE_NOT_AVAILABLE - it failed to measure it, or the measurement was not complete yet. - FE_SCALE_COUNTER - Number of blocks counted while measuring - DTV_STAT_ERROR_BLOCK_COUNT. + FE_SCALE_NOT_AVAILABLE - it failed to measure it, or the measurement was not complete yet. + FE_SCALE_COUNTER - Number of blocks counted while measuring + DTV_STAT_ERROR_BLOCK_COUNT.
-- cgit v1.1