summaryrefslogtreecommitdiffstats
path: root/fs/ceph/ioctl.c
Commit message (Collapse)AuthorAgeFilesLines
* ceph: add F_SYNC file flag to force sync (non-O_DIRECT) ioSage Weil2011-07-261-0/+11
| | | | | | | | | | This allows us to force IO through the sync path which you normally only get when multiple clients are reading/writing to the same file or by mounting with -o sync. Among other things, this lets test programs verify correctness with a single mount. Reviewed-by: Yehuda Sadeh <yehuda@hq.newdream.net> Signed-off-by: Sage Weil <sage@newdream.net>
* ceph: use ihold when we already have an inode refSage Weil2011-06-071-2/+4
| | | | | | | | We should use ihold whenever we already have a stable inode ref, even when we aren't holding i_lock. This avoids adding new and unnecessary locking dependencies. Signed-off-by: Sage Weil <sage@newdream.net>
* ceph: add CEPH_MDS_OP_SETDIRLAYOUT and associated ioctl.Greg Farnum2010-10-201-0/+66
| | | | Signed-off-by: Sage Weil <sage@newdream.net>
* ceph: factor out libceph from Ceph file systemYehuda Sadeh2010-10-201-4/+7
| | | | | | | | | | | | | | | | | | | | | | This factors out protocol and low-level storage parts of ceph into a separate libceph module living in net/ceph and include/linux/ceph. This is mostly a matter of moving files around. However, a few key pieces of the interface change as well: - ceph_client becomes ceph_fs_client and ceph_client, where the latter captures the mon and osd clients, and the fs_client gets the mds client and file system specific pieces. - Mount option parsing and debugfs setup is correspondingly broken into two pieces. - The mon client gets a generic handler callback for otherwise unknown messages (mds map, in this case). - The basic supported/required feature bits can be expanded (and are by ceph_fs_client). No functional change, aside from some subtle error handling cases that got cleaned up in the refactoring process. Signed-off-by: Sage Weil <sage@newdream.net>
* ceph: add LAZYIO ioctl to mark a file description for lazy consistencySage Weil2010-08-011-0/+24
| | | | | | | | Allow an application to mark a file descriptor for lazy file consistency semantics, allowing buffered reads and writes when multiple clients are accessing the same file. Signed-off-by: Sage Weil <sage@newdream.net>
* ceph: use ceph_sb_to_client instead of ceph_clientCheng Renquan2010-05-171-1/+1
| | | | | | | | | | | | | | | ceph_sb_to_client and ceph_client are really identical, we need to dump one; while function ceph_client is confusing with "struct ceph_client", ceph_sb_to_client's definition is more clear; so we'd better switch all call to ceph_sb_to_client. -static inline struct ceph_client *ceph_client(struct super_block *sb) -{ - return sb->s_fs_info; -} Signed-off-by: Cheng Renquan <crquan@gmail.com> Signed-off-by: Sage Weil <sage@newdream.net>
* ceph: allow preferred osd to be get/set via layout ioctlSage Weil2009-12-031-1/+4
| | | | | | | | | There is certainly no reason not to report this. The only real downside to allowing the user to set it is that you don't get default values by zeroing the layout struct (the default is -1). Signed-off-by: Sage Weil <sage@newdream.net>
* ceph: fix endian conversions for ceph_pgSage Weil2009-11-041-2/+2
| | | | | | | | The endian conversions don't quite work with the old union ceph_pg. Just make it a regular struct, and make each field __le. This is simpler and it has the added bonus of actually working. Signed-off-by: Sage Weil <sage@newdream.net>
* ceph: ioctlsSage Weil2009-10-061-0/+157
A few Ceph ioctls for getting and setting file layout (striping) parameters, and learning the identity and network address of the OSD a given region of a file is stored on. Signed-off-by: Sage Weil <sage@newdream.net>
OpenPOWER on IntegriCloud