summaryrefslogtreecommitdiffstats
path: root/security/selinux/netif.c
diff options
context:
space:
mode:
Diffstat (limited to 'security/selinux/netif.c')
-rw-r--r--security/selinux/netif.c43
1 files changed, 23 insertions, 20 deletions
diff --git a/security/selinux/netif.c b/security/selinux/netif.c
index 50ce177..e607b44 100644
--- a/security/selinux/netif.c
+++ b/security/selinux/netif.c
@@ -45,6 +45,7 @@ static struct list_head sel_netif_hash[SEL_NETIF_HASH_SIZE];
/**
* sel_netif_hashfn - Hashing function for the interface table
+ * @ns: the network namespace
* @ifindex: the network interface
*
* Description:
@@ -52,13 +53,14 @@ static struct list_head sel_netif_hash[SEL_NETIF_HASH_SIZE];
* bucket number for the given interface.
*
*/
-static inline u32 sel_netif_hashfn(int ifindex)
+static inline u32 sel_netif_hashfn(const struct net *ns, int ifindex)
{
- return (ifindex & (SEL_NETIF_HASH_SIZE - 1));
+ return (((uintptr_t)ns + ifindex) & (SEL_NETIF_HASH_SIZE - 1));
}
/**
* sel_netif_find - Search for an interface record
+ * @ns: the network namespace
* @ifindex: the network interface
*
* Description:
@@ -66,15 +68,15 @@ static inline u32 sel_netif_hashfn(int ifindex)
* If an entry can not be found in the table return NULL.
*
*/
-static inline struct sel_netif *sel_netif_find(int ifindex)
+static inline struct sel_netif *sel_netif_find(const struct net *ns,
+ int ifindex)
{
- int idx = sel_netif_hashfn(ifindex);
+ int idx = sel_netif_hashfn(ns, ifindex);
struct sel_netif *netif;
list_for_each_entry_rcu(netif, &sel_netif_hash[idx], list)
- /* all of the devices should normally fit in the hash, so we
- * optimize for that case */
- if (likely(netif->nsec.ifindex == ifindex))
+ if (net_eq(netif->nsec.ns, ns) &&
+ netif->nsec.ifindex == ifindex)
return netif;
return NULL;
@@ -96,7 +98,7 @@ static int sel_netif_insert(struct sel_netif *netif)
if (sel_netif_total >= SEL_NETIF_HASH_MAX)
return -ENOSPC;
- idx = sel_netif_hashfn(netif->nsec.ifindex);
+ idx = sel_netif_hashfn(netif->nsec.ns, netif->nsec.ifindex);
list_add_rcu(&netif->list, &sel_netif_hash[idx]);
sel_netif_total++;
@@ -120,6 +122,7 @@ static void sel_netif_destroy(struct sel_netif *netif)
/**
* sel_netif_sid_slow - Lookup the SID of a network interface using the policy
+ * @ns: the network namespace
* @ifindex: the network interface
* @sid: interface SID
*
@@ -130,7 +133,7 @@ static void sel_netif_destroy(struct sel_netif *netif)
* failure.
*
*/
-static int sel_netif_sid_slow(int ifindex, u32 *sid)
+static int sel_netif_sid_slow(struct net *ns, int ifindex, u32 *sid)
{
int ret;
struct sel_netif *netif;
@@ -140,7 +143,7 @@ static int sel_netif_sid_slow(int ifindex, u32 *sid)
/* NOTE: we always use init's network namespace since we don't
* currently support containers */
- dev = dev_get_by_index(&init_net, ifindex);
+ dev = dev_get_by_index(ns, ifindex);
if (unlikely(dev == NULL)) {
printk(KERN_WARNING
"SELinux: failure in sel_netif_sid_slow(),"
@@ -149,7 +152,7 @@ static int sel_netif_sid_slow(int ifindex, u32 *sid)
}
spin_lock_bh(&sel_netif_lock);
- netif = sel_netif_find(ifindex);
+ netif = sel_netif_find(ns, ifindex);
if (netif != NULL) {
*sid = netif->nsec.sid;
ret = 0;
@@ -163,6 +166,7 @@ static int sel_netif_sid_slow(int ifindex, u32 *sid)
ret = security_netif_sid(dev->name, &new->nsec.sid);
if (ret != 0)
goto out;
+ new->nsec.ns = ns;
new->nsec.ifindex = ifindex;
ret = sel_netif_insert(new);
if (ret != 0)
@@ -184,6 +188,7 @@ out:
/**
* sel_netif_sid - Lookup the SID of a network interface
+ * @ns: the network namespace
* @ifindex: the network interface
* @sid: interface SID
*
@@ -195,12 +200,12 @@ out:
* on failure.
*
*/
-int sel_netif_sid(int ifindex, u32 *sid)
+int sel_netif_sid(struct net *ns, int ifindex, u32 *sid)
{
struct sel_netif *netif;
rcu_read_lock();
- netif = sel_netif_find(ifindex);
+ netif = sel_netif_find(ns, ifindex);
if (likely(netif != NULL)) {
*sid = netif->nsec.sid;
rcu_read_unlock();
@@ -208,11 +213,12 @@ int sel_netif_sid(int ifindex, u32 *sid)
}
rcu_read_unlock();
- return sel_netif_sid_slow(ifindex, sid);
+ return sel_netif_sid_slow(ns, ifindex, sid);
}
/**
* sel_netif_kill - Remove an entry from the network interface table
+ * @ns: the network namespace
* @ifindex: the network interface
*
* Description:
@@ -220,13 +226,13 @@ int sel_netif_sid(int ifindex, u32 *sid)
* table if it exists.
*
*/
-static void sel_netif_kill(int ifindex)
+static void sel_netif_kill(const struct net *ns, int ifindex)
{
struct sel_netif *netif;
rcu_read_lock();
spin_lock_bh(&sel_netif_lock);
- netif = sel_netif_find(ifindex);
+ netif = sel_netif_find(ns, ifindex);
if (netif)
sel_netif_destroy(netif);
spin_unlock_bh(&sel_netif_lock);
@@ -257,11 +263,8 @@ static int sel_netif_netdev_notifier_handler(struct notifier_block *this,
{
struct net_device *dev = netdev_notifier_info_to_dev(ptr);
- if (dev_net(dev) != &init_net)
- return NOTIFY_DONE;
-
if (event == NETDEV_DOWN)
- sel_netif_kill(dev->ifindex);
+ sel_netif_kill(dev_net(dev), dev->ifindex);
return NOTIFY_DONE;
}
OpenPOWER on IntegriCloud