summaryrefslogtreecommitdiffstats
path: root/kernel/sched.c
diff options
context:
space:
mode:
Diffstat (limited to 'kernel/sched.c')
-rw-r--r--kernel/sched.c67
1 files changed, 50 insertions, 17 deletions
diff --git a/kernel/sched.c b/kernel/sched.c
index 552faf8..2b942e4 100644
--- a/kernel/sched.c
+++ b/kernel/sched.c
@@ -5804,17 +5804,46 @@ static struct notifier_block __cpuinitdata migration_notifier = {
.priority = CPU_PRI_MIGRATION,
};
+static int __cpuinit sched_cpu_active(struct notifier_block *nfb,
+ unsigned long action, void *hcpu)
+{
+ switch (action & ~CPU_TASKS_FROZEN) {
+ case CPU_ONLINE:
+ case CPU_DOWN_FAILED:
+ set_cpu_active((long)hcpu, true);
+ return NOTIFY_OK;
+ default:
+ return NOTIFY_DONE;
+ }
+}
+
+static int __cpuinit sched_cpu_inactive(struct notifier_block *nfb,
+ unsigned long action, void *hcpu)
+{
+ switch (action & ~CPU_TASKS_FROZEN) {
+ case CPU_DOWN_PREPARE:
+ set_cpu_active((long)hcpu, false);
+ return NOTIFY_OK;
+ default:
+ return NOTIFY_DONE;
+ }
+}
+
static int __init migration_init(void)
{
void *cpu = (void *)(long)smp_processor_id();
int err;
- /* Start one for the boot CPU: */
+ /* Initialize migration for the boot CPU */
err = migration_call(&migration_notifier, CPU_UP_PREPARE, cpu);
BUG_ON(err == NOTIFY_BAD);
migration_call(&migration_notifier, CPU_ONLINE, cpu);
register_cpu_notifier(&migration_notifier);
+ /* Register cpu active notifiers */
+ cpu_notifier(sched_cpu_active, CPU_PRI_SCHED_ACTIVE);
+ cpu_notifier(sched_cpu_inactive, CPU_PRI_SCHED_INACTIVE);
+
return 0;
}
early_initcall(migration_init);
@@ -7273,29 +7302,35 @@ int __init sched_create_sysfs_power_savings_entries(struct sysdev_class *cls)
}
#endif /* CONFIG_SCHED_MC || CONFIG_SCHED_SMT */
-#ifndef CONFIG_CPUSETS
/*
- * Add online and remove offline CPUs from the scheduler domains.
- * When cpusets are enabled they take over this function.
+ * Update cpusets according to cpu_active mask. If cpusets are
+ * disabled, cpuset_update_active_cpus() becomes a simple wrapper
+ * around partition_sched_domains().
*/
-static int update_sched_domains(struct notifier_block *nfb,
- unsigned long action, void *hcpu)
+static int __cpuexit cpuset_cpu_active(struct notifier_block *nfb,
+ unsigned long action, void *hcpu)
{
- switch (action) {
+ switch (action & ~CPU_TASKS_FROZEN) {
case CPU_ONLINE:
- case CPU_ONLINE_FROZEN:
- case CPU_DOWN_PREPARE:
- case CPU_DOWN_PREPARE_FROZEN:
case CPU_DOWN_FAILED:
- case CPU_DOWN_FAILED_FROZEN:
- partition_sched_domains(1, NULL, NULL);
+ cpuset_update_active_cpus();
return NOTIFY_OK;
+ default:
+ return NOTIFY_DONE;
+ }
+}
+static int __cpuexit cpuset_cpu_inactive(struct notifier_block *nfb,
+ unsigned long action, void *hcpu)
+{
+ switch (action & ~CPU_TASKS_FROZEN) {
+ case CPU_DOWN_PREPARE:
+ cpuset_update_active_cpus();
+ return NOTIFY_OK;
default:
return NOTIFY_DONE;
}
}
-#endif
static int update_runtime(struct notifier_block *nfb,
unsigned long action, void *hcpu)
@@ -7341,10 +7376,8 @@ void __init sched_init_smp(void)
mutex_unlock(&sched_domains_mutex);
put_online_cpus();
-#ifndef CONFIG_CPUSETS
- /* XXX: Theoretical race here - CPU may be hotplugged now */
- hotcpu_notifier(update_sched_domains, 0);
-#endif
+ hotcpu_notifier(cpuset_cpu_active, CPU_PRI_CPUSET_ACTIVE);
+ hotcpu_notifier(cpuset_cpu_inactive, CPU_PRI_CPUSET_INACTIVE);
/* RT runtime code needs to handle some hotplug events */
hotcpu_notifier(update_runtime, 0);
OpenPOWER on IntegriCloud