summaryrefslogtreecommitdiffstats
path: root/include/linux/thermal.h
diff options
context:
space:
mode:
Diffstat (limited to 'include/linux/thermal.h')
-rw-r--r--include/linux/thermal.h56
1 files changed, 54 insertions, 2 deletions
diff --git a/include/linux/thermal.h b/include/linux/thermal.h
index fc52e30..5eac316 100644
--- a/include/linux/thermal.h
+++ b/include/linux/thermal.h
@@ -314,6 +314,8 @@ void thermal_zone_of_sensor_unregister(struct device *dev,
}
#endif
+
+#if IS_ENABLED(CONFIG_THERMAL)
struct thermal_zone_device *thermal_zone_device_register(const char *, int, int,
void *, struct thermal_zone_device_ops *,
const struct thermal_zone_params *, int, int);
@@ -340,8 +342,58 @@ struct thermal_instance *get_thermal_instance(struct thermal_zone_device *,
struct thermal_cooling_device *, int);
void thermal_cdev_update(struct thermal_cooling_device *);
void thermal_notify_framework(struct thermal_zone_device *, int);
-
-#ifdef CONFIG_NET
+#else
+static inline struct thermal_zone_device *thermal_zone_device_register(
+ const char *type, int trips, int mask, void *devdata,
+ struct thermal_zone_device_ops *ops,
+ const struct thermal_zone_params *tzp,
+ int passive_delay, int polling_delay)
+{ return ERR_PTR(-ENODEV); }
+static inline void thermal_zone_device_unregister(
+ struct thermal_zone_device *tz)
+{ }
+static inline int thermal_zone_bind_cooling_device(
+ struct thermal_zone_device *tz, int trip,
+ struct thermal_cooling_device *cdev,
+ unsigned long upper, unsigned long lower)
+{ return -ENODEV; }
+static inline int thermal_zone_unbind_cooling_device(
+ struct thermal_zone_device *tz, int trip,
+ struct thermal_cooling_device *cdev)
+{ return -ENODEV; }
+static inline void thermal_zone_device_update(struct thermal_zone_device *tz)
+{ }
+static inline struct thermal_cooling_device *
+thermal_cooling_device_register(char *type, void *devdata,
+ const struct thermal_cooling_device_ops *ops)
+{ return ERR_PTR(-ENODEV); }
+static inline struct thermal_cooling_device *
+thermal_of_cooling_device_register(struct device_node *np,
+ char *type, void *devdata, const struct thermal_cooling_device_ops *ops)
+{ return ERR_PTR(-ENODEV); }
+static inline void thermal_cooling_device_unregister(
+ struct thermal_cooling_device *cdev)
+{ }
+static inline struct thermal_zone_device *thermal_zone_get_zone_by_name(
+ const char *name)
+{ return ERR_PTR(-ENODEV); }
+static inline int thermal_zone_get_temp(
+ struct thermal_zone_device *tz, unsigned long *temp)
+{ return -ENODEV; }
+static inline int get_tz_trend(struct thermal_zone_device *tz, int trip)
+{ return -ENODEV; }
+static inline struct thermal_instance *
+get_thermal_instance(struct thermal_zone_device *tz,
+ struct thermal_cooling_device *cdev, int trip)
+{ return ERR_PTR(-ENODEV); }
+static inline void thermal_cdev_update(struct thermal_cooling_device *cdev)
+{ }
+static inline void thermal_notify_framework(struct thermal_zone_device *tz,
+ int trip)
+{ }
+#endif /* CONFIG_THERMAL */
+
+#if defined(CONFIG_NET) && IS_ENABLED(CONFIG_THERMAL)
extern int thermal_generate_netlink_event(struct thermal_zone_device *tz,
enum events event);
#else
OpenPOWER on IntegriCloud