summaryrefslogtreecommitdiffstats
path: root/include/linux/sched.h
diff options
context:
space:
mode:
Diffstat (limited to 'include/linux/sched.h')
-rw-r--r--include/linux/sched.h92
1 files changed, 72 insertions, 20 deletions
diff --git a/include/linux/sched.h b/include/linux/sched.h
index 8395e71..158d53d 100644
--- a/include/linux/sched.h
+++ b/include/linux/sched.h
@@ -250,7 +250,7 @@ extern void init_idle_bootup_task(struct task_struct *idle);
extern int runqueue_is_locked(void);
extern void task_rq_unlock_wait(struct task_struct *p);
-extern cpumask_t nohz_cpu_mask;
+extern cpumask_var_t nohz_cpu_mask;
#if defined(CONFIG_SMP) && defined(CONFIG_NO_HZ)
extern int select_nohz_load_balancer(int cpu);
#else
@@ -758,20 +758,51 @@ enum cpu_idle_type {
#define SD_SERIALIZE 1024 /* Only a single load balancing instance */
#define SD_WAKE_IDLE_FAR 2048 /* Gain latency sacrificing cache hit */
-#define BALANCE_FOR_MC_POWER \
- (sched_smt_power_savings ? SD_POWERSAVINGS_BALANCE : 0)
+enum powersavings_balance_level {
+ POWERSAVINGS_BALANCE_NONE = 0, /* No power saving load balance */
+ POWERSAVINGS_BALANCE_BASIC, /* Fill one thread/core/package
+ * first for long running threads
+ */
+ POWERSAVINGS_BALANCE_WAKEUP, /* Also bias task wakeups to semi-idle
+ * cpu package for power savings
+ */
+ MAX_POWERSAVINGS_BALANCE_LEVELS
+};
-#define BALANCE_FOR_PKG_POWER \
- ((sched_mc_power_savings || sched_smt_power_savings) ? \
- SD_POWERSAVINGS_BALANCE : 0)
+extern int sched_mc_power_savings, sched_smt_power_savings;
-#define test_sd_parent(sd, flag) ((sd->parent && \
- (sd->parent->flags & flag)) ? 1 : 0)
+static inline int sd_balance_for_mc_power(void)
+{
+ if (sched_smt_power_savings)
+ return SD_POWERSAVINGS_BALANCE;
+ return 0;
+}
+
+static inline int sd_balance_for_package_power(void)
+{
+ if (sched_mc_power_savings | sched_smt_power_savings)
+ return SD_POWERSAVINGS_BALANCE;
+
+ return 0;
+}
+
+/*
+ * Optimise SD flags for power savings:
+ * SD_BALANCE_NEWIDLE helps agressive task consolidation and power savings.
+ * Keep default SD flags if sched_{smt,mc}_power_saving=0
+ */
+
+static inline int sd_power_saving_flags(void)
+{
+ if (sched_mc_power_savings | sched_smt_power_savings)
+ return SD_BALANCE_NEWIDLE;
+
+ return 0;
+}
struct sched_group {
struct sched_group *next; /* Must be a circular list */
- cpumask_t cpumask;
/*
* CPU power of this group, SCHED_LOAD_SCALE being max power for a
@@ -784,8 +815,15 @@ struct sched_group {
* (see include/linux/reciprocal_div.h)
*/
u32 reciprocal_cpu_power;
+
+ unsigned long cpumask[];
};
+static inline struct cpumask *sched_group_cpus(struct sched_group *sg)
+{
+ return to_cpumask(sg->cpumask);
+}
+
enum sched_domain_level {
SD_LV_NONE = 0,
SD_LV_SIBLING,
@@ -809,7 +847,6 @@ struct sched_domain {
struct sched_domain *parent; /* top domain must be null terminated */
struct sched_domain *child; /* bottom domain must be null terminated */
struct sched_group *groups; /* the balancing groups of the domain */
- cpumask_t span; /* span of all CPUs in this domain */
unsigned long min_interval; /* Minimum balance interval ms */
unsigned long max_interval; /* Maximum balance interval ms */
unsigned int busy_factor; /* less balancing by factor if busy */
@@ -864,18 +901,35 @@ struct sched_domain {
#ifdef CONFIG_SCHED_DEBUG
char *name;
#endif
+
+ /* span of all CPUs in this domain */
+ unsigned long span[];
};
-extern void partition_sched_domains(int ndoms_new, cpumask_t *doms_new,
+static inline struct cpumask *sched_domain_span(struct sched_domain *sd)
+{
+ return to_cpumask(sd->span);
+}
+
+extern void partition_sched_domains(int ndoms_new, struct cpumask *doms_new,
struct sched_domain_attr *dattr_new);
extern int arch_reinit_sched_domains(void);
+/* Test a flag in parent sched domain */
+static inline int test_sd_parent(struct sched_domain *sd, int flag)
+{
+ if (sd->parent && (sd->parent->flags & flag))
+ return 1;
+
+ return 0;
+}
+
#else /* CONFIG_SMP */
struct sched_domain_attr;
static inline void
-partition_sched_domains(int ndoms_new, cpumask_t *doms_new,
+partition_sched_domains(int ndoms_new, struct cpumask *doms_new,
struct sched_domain_attr *dattr_new)
{
}
@@ -926,7 +980,7 @@ struct sched_class {
void (*task_wake_up) (struct rq *this_rq, struct task_struct *task);
void (*set_cpus_allowed)(struct task_struct *p,
- const cpumask_t *newmask);
+ const struct cpumask *newmask);
void (*rq_online)(struct rq *rq);
void (*rq_offline)(struct rq *rq);
@@ -1579,12 +1633,12 @@ extern cputime_t task_gtime(struct task_struct *p);
#ifdef CONFIG_SMP
extern int set_cpus_allowed_ptr(struct task_struct *p,
- const cpumask_t *new_mask);
+ const struct cpumask *new_mask);
#else
static inline int set_cpus_allowed_ptr(struct task_struct *p,
- const cpumask_t *new_mask)
+ const struct cpumask *new_mask)
{
- if (!cpu_isset(0, *new_mask))
+ if (!cpumask_test_cpu(0, new_mask))
return -EINVAL;
return 0;
}
@@ -2195,10 +2249,8 @@ __trace_special(void *__tr, void *__data,
}
#endif
-extern long sched_setaffinity(pid_t pid, const cpumask_t *new_mask);
-extern long sched_getaffinity(pid_t pid, cpumask_t *mask);
-
-extern int sched_mc_power_savings, sched_smt_power_savings;
+extern long sched_setaffinity(pid_t pid, const struct cpumask *new_mask);
+extern long sched_getaffinity(pid_t pid, struct cpumask *mask);
extern void normalize_rt_tasks(void);
OpenPOWER on IntegriCloud