-rw-r--r--drivers/power/charger-manager.c229
1 files changed, 229 insertions, 0 deletions
diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c
index 9eca9f1..959062d 100644
--- a/drivers/power/charger-manager.c
+++ b/drivers/power/charger-manager.c
@@ -57,6 +57,12 @@ static bool cm_suspended;
static bool cm_rtc_set;
static unsigned long cm_suspend_duration_ms;
+/* About normal (not suspended) monitoring */
+static unsigned long polling_jiffy = ULONG_MAX; /* ULONG_MAX: no polling */
+static unsigned long next_polling; /* Next appointed polling time */
+static struct workqueue_struct *cm_wq; /* init at driver add */
+static struct delayed_work cm_monitor_work; /* init at driver add */
+
/* Global charger-manager description */
static struct charger_global_desc *g_desc; /* init with setup_charger_manager */
@@ -71,6 +77,11 @@ static bool is_batt_present(struct charger_manager *cm)
int i, ret;
switch (cm->desc->battery_present) {
+ case CM_BATTERY_PRESENT:
+ present = true;
+ break;
+ case CM_NO_BATTERY:
+ break;
case CM_FUEL_GAUGE:
ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
POWER_SUPPLY_PROP_PRESENT, &val);
@@ -279,6 +290,26 @@ static int try_charger_enable(struct charger_manager *cm, bool enable)
}
/**
+ * try_charger_restart - Restart charging.
+ * @cm: the Charger Manager representing the battery.
+ *
+ * Restart charging by turning off and on the charger.
+ */
+static int try_charger_restart(struct charger_manager *cm)
+{
+ int err;
+
+ if (cm->emergency_stop)
+ return -EAGAIN;
+
+ err = try_charger_enable(cm, false);
+ if (err)
+ return err;
+
+ return try_charger_enable(cm, true);
+}
+
+/**
* uevent_notify - Let users know something has changed.
* @cm: the Charger Manager representing the battery.
* @event: the event string.
@@ -334,6 +365,46 @@ static void uevent_notify(struct charger_manager *cm, const char *event)
}
/**
+ * fullbatt_vchk - Check voltage drop some times after "FULL" event.
+ * @work: the work_struct appointing the function
+ *
+ * If a user has designated "fullbatt_vchkdrop_ms/uV" values with
+ * charger_desc, Charger Manager checks voltage drop after the battery
+ * "FULL" event. It checks whether the voltage has dropped more than
+ * fullbatt_vchkdrop_uV by calling this function after fullbatt_vchkrop_ms.
+ */
+static void fullbatt_vchk(struct work_struct *work)
+{
+ struct delayed_work *dwork = to_delayed_work(work);
+ struct charger_manager *cm = container_of(dwork,
+ struct charger_manager, fullbatt_vchk_work);
+ struct charger_desc *desc = cm->desc;
+ int batt_uV, err, diff;
+
+ /* remove the appointment for fullbatt_vchk */
+ cm->fullbatt_vchk_jiffies_at = 0;
+
+ if (!desc->fullbatt_vchkdrop_uV || !desc->fullbatt_vchkdrop_ms)
+ return;
+
+ err = get_batt_uV(cm, &batt_uV);
+ if (err) {
+ dev_err(cm->dev, "%s: get_batt_uV error(%d).\n", __func__, err);
+ return;
+ }
+
+ diff = cm->fullbatt_vchk_uV;
+ diff -= batt_uV;
+
+ dev_dbg(cm->dev, "VBATT dropped %duV after full-batt.\n", diff);
+
+ if (diff > desc->fullbatt_vchkdrop_uV) {
+ try_charger_restart(cm);
+ uevent_notify(cm, "Recharge");
+ }
+}
+
+/**
* _cm_monitor - Monitor the temperature and return true for exceptions.
* @cm: the Charger Manager representing the battery.
*
@@ -392,6 +463,68 @@ static bool cm_monitor(void)
return stop;
}
+/**
+ * _setup_polling - Setup the next instance of polling.
+ * @work: work_struct of the function _setup_polling.
+ */
+static void _setup_polling(struct work_struct *work)
+{
+ unsigned long min = ULONG_MAX;
+ struct charger_manager *cm;
+ bool keep_polling = false;
+ unsigned long _next_polling;
+
+ mutex_lock(&cm_list_mtx);
+
+ list_for_each_entry(cm, &cm_list, entry) {
+ if (is_polling_required(cm) && cm->desc->polling_interval_ms) {
+ keep_polling = true;
+
+ if (min > cm->desc->polling_interval_ms)
+ min = cm->desc->polling_interval_ms;
+ }
+ }
+
+ polling_jiffy = msecs_to_jiffies(min);
+ if (polling_jiffy <= CM_JIFFIES_SMALL)
+ polling_jiffy = CM_JIFFIES_SMALL + 1;
+
+ if (!keep_polling)
+ polling_jiffy = ULONG_MAX;
+ if (polling_jiffy == ULONG_MAX)
+ goto out;
+
+ WARN(cm_wq == NULL, "charger-manager: workqueue not initialized"
+ ". try it later. %s\n", __func__);
+
+ _next_polling = jiffies + polling_jiffy;
+
+ if (!delayed_work_pending(&cm_monitor_work) ||
+ (delayed_work_pending(&cm_monitor_work) &&
+ time_after(next_polling, _next_polling))) {
+ cancel_delayed_work_sync(&cm_monitor_work);
+ next_polling = jiffies + polling_jiffy;
+ queue_delayed_work(cm_wq, &cm_monitor_work, polling_jiffy);
+ }
+
+out:
+ mutex_unlock(&cm_list_mtx);
+}
+static DECLARE_WORK(setup_polling, _setup_polling);
+
+/**
+ * cm_monitor_poller - The Monitor / Poller.
+ * @work: work_struct of the function cm_monitor_poller
+ *
+ * During non-suspended state, cm_monitor_poller is used to poll and monitor
+ * the batteries.
+ */
+static void cm_monitor_poller(struct work_struct *work)
+{
+ cm_monitor();
+ schedule_work(&setup_polling);
+}
+
static int charger_get_property(struct power_supply *psy,
enum power_supply_property psp,
union power_supply_propval *val)
@@ -613,6 +746,21 @@ static bool cm_setup_timer(void)
mutex_lock(&cm_list_mtx);
list_for_each_entry(cm, &cm_list, entry) {
+ unsigned int fbchk_ms = 0;
+
+ /* fullbatt_vchk is required. setup timer for that */
+ if (cm->fullbatt_vchk_jiffies_at) {
+ fbchk_ms = jiffies_to_msecs(cm->fullbatt_vchk_jiffies_at
+ - jiffies);
+ if (time_is_before_eq_jiffies(
+ cm->fullbatt_vchk_jiffies_at) ||
+ msecs_to_jiffies(fbchk_ms) < CM_JIFFIES_SMALL) {
+ fullbatt_vchk(&cm->fullbatt_vchk_work.work);
+ fbchk_ms = 0;
+ }
+ }
+ CM_MIN_VALID(wakeup_ms, fbchk_ms);
+
/* Skip if polling is not required for this CM */
if (!is_polling_required(cm) && !cm->emergency_stop)
continue;
@@ -672,6 +820,23 @@ static bool cm_setup_timer(void)
return false;
}
+static void _cm_fbchk_in_suspend(struct charger_manager *cm)
+{
+ unsigned long jiffy_now = jiffies;
+
+ if (!cm->fullbatt_vchk_jiffies_at)
+ return;
+
+ if (g_desc && g_desc->assume_timer_stops_in_suspend)
+ jiffy_now += msecs_to_jiffies(cm_suspend_duration_ms);
+
+ /* Execute now if it's going to be executed not too long after */
+ jiffy_now += CM_JIFFIES_SMALL;
+
+ if (time_after_eq(jiffy_now, cm->fullbatt_vchk_jiffies_at))
+ fullbatt_vchk(&cm->fullbatt_vchk_work.work);
+}
+
/**
* cm_suspend_again - Determine whether suspend again or not
*
@@ -693,6 +858,8 @@ bool cm_suspend_again(void)
ret = true;
mutex_lock(&cm_list_mtx);
list_for_each_entry(cm, &cm_list, entry) {
+ _cm_fbchk_in_suspend(cm);
+
if (cm->status_save_ext_pwr_inserted != is_ext_pwr_online(cm) ||
cm->status_save_batt != is_batt_present(cm)) {
ret = false;
@@ -796,6 +963,21 @@ static int charger_manager_probe(struct platform_device *pdev)
memcpy(cm->desc, desc, sizeof(struct charger_desc));
cm->last_temp_mC = INT_MIN; /* denotes "unmeasured, yet" */
+ /*
+ * The following two do not need to be errors.
+ * Users may intentionally ignore those two features.
+ */
+ if (desc->fullbatt_uV == 0) {
+ dev_info(&pdev->dev, "Ignoring full-battery voltage threshold"
+ " as it is not supplied.");
+ }
+ if (!desc->fullbatt_vchkdrop_ms || !desc->fullbatt_vchkdrop_uV) {
+ dev_info(&pdev->dev, "Disabling full-battery voltage drop "
+ "checking mechanism as it is not supplied.");
+ desc->fullbatt_vchkdrop_ms = 0;
+ desc->fullbatt_vchkdrop_uV = 0;
+ }
+
if (!desc->charger_regulators || desc->num_charger_regulators < 1) {
ret = -EINVAL;
dev_err(&pdev->dev, "charger_regulators undefined.\n");
@@ -903,6 +1085,8 @@ static int charger_manager_probe(struct platform_device *pdev)
cm->charger_psy.num_properties++;
}
+ INIT_DELAYED_WORK(&cm->fullbatt_vchk_work, fullbatt_vchk);
+
ret = power_supply_register(NULL, &cm->charger_psy);
if (ret) {
dev_err(&pdev->dev, "Cannot register charger-manager with"
@@ -928,6 +1112,8 @@ static int charger_manager_probe(struct platform_device *pdev)
list_add(&cm->entry, &cm_list);
mutex_unlock(&cm_list_mtx);
+ schedule_work(&setup_polling);
+
return 0;
err_chg_enable:
@@ -958,9 +1144,17 @@ static int __devexit charger_manager_remove(struct platform_device *pdev)
list_del(&cm->entry);
mutex_unlock(&cm_list_mtx);
+ if (work_pending(&setup_polling))
+ cancel_work_sync(&setup_polling);
+ if (delayed_work_pending(&cm_monitor_work))
+ cancel_delayed_work_sync(&cm_monitor_work);
+
regulator_bulk_free(desc->num_charger_regulators,
desc->charger_regulators);
power_supply_unregister(&cm->charger_psy);
+
+ try_charger_enable(cm, false);
+
kfree(cm->charger_psy.properties);
kfree(cm->charger_stat);
kfree(cm->desc);
@@ -1000,6 +1194,8 @@ static int cm_suspend_prepare(struct device *dev)
cm_suspended = true;
}
+ if (delayed_work_pending(&cm->fullbatt_vchk_work))
+ cancel_delayed_work(&cm->fullbatt_vchk_work);
cm->status_save_ext_pwr_inserted = is_ext_pwr_online(cm);
cm->status_save_batt = is_batt_present(cm);
@@ -1027,6 +1223,33 @@ static void cm_suspend_complete(struct device *dev)
cm_rtc_set = false;
}
+ /* Re-enqueue delayed work (fullbatt_vchk_work) */
+ if (cm->fullbatt_vchk_jiffies_at) {
+ unsigned long delay = 0;
+ unsigned long now = jiffies + CM_JIFFIES_SMALL;
+
+ if (time_after_eq(now, cm->fullbatt_vchk_jiffies_at)) {
+ delay = (unsigned long)((long)now
+ - (long)(cm->fullbatt_vchk_jiffies_at));
+ delay = jiffies_to_msecs(delay);
+ } else {
+ delay = 0;
+ }
+
+ /*
+ * Account for cm_suspend_duration_ms if
+ * assume_timer_stops_in_suspend is active
+ */
+ if (g_desc && g_desc->assume_timer_stops_in_suspend) {
+ if (delay > cm_suspend_duration_ms)
+ delay -= cm_suspend_duration_ms;
+ else
+ delay = 0;
+ }
+
+ queue_delayed_work(cm_wq, &cm->fullbatt_vchk_work,
+ msecs_to_jiffies(delay));
+ }
uevent_notify(cm, NULL);
}
@@ -1048,12 +1271,18 @@ static struct platform_driver charger_manager_driver = {
static int __init charger_manager_init(void)
{
+ cm_wq = create_freezable_workqueue("charger_manager");
+ INIT_DELAYED_WORK(&cm_monitor_work, cm_monitor_poller);
+
return platform_driver_register(&charger_manager_driver);
}
late_initcall(charger_manager_init);
static void __exit charger_manager_cleanup(void)
{
+ destroy_workqueue(cm_wq);
+ cm_wq = NULL;
+
platform_driver_unregister(&charger_manager_driver);
}
module_exit(charger_manager_cleanup);