summaryrefslogtreecommitdiffstats
path: root/drivers/thermal
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/thermal')
-rw-r--r--drivers/thermal/cpu_cooling.c37
-rw-r--r--drivers/thermal/imx_thermal.c45
-rw-r--r--drivers/thermal/int340x_thermal/int3403_thermal.c8
-rw-r--r--drivers/thermal/samsung/exynos_thermal_common.c9
-rw-r--r--drivers/thermal/samsung/exynos_tmu_data.c1
-rw-r--r--drivers/thermal/samsung/exynos_tmu_data.h1
-rw-r--r--drivers/thermal/st/st_thermal.c3
7 files changed, 63 insertions, 41 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
index 1ab0018..ad09e51 100644
--- a/drivers/thermal/cpu_cooling.c
+++ b/drivers/thermal/cpu_cooling.c
@@ -50,15 +50,14 @@ struct cpufreq_cooling_device {
unsigned int cpufreq_state;
unsigned int cpufreq_val;
struct cpumask allowed_cpus;
+ struct list_head node;
};
static DEFINE_IDR(cpufreq_idr);
static DEFINE_MUTEX(cooling_cpufreq_lock);
static unsigned int cpufreq_dev_count;
-/* notify_table passes value to the CPUFREQ_ADJUST callback function. */
-#define NOTIFY_INVALID NULL
-static struct cpufreq_cooling_device *notify_device;
+static LIST_HEAD(cpufreq_dev_list);
/**
* get_idr - function to get a unique id.
@@ -287,15 +286,12 @@ static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device,
cpufreq_device->cpufreq_state = cooling_state;
cpufreq_device->cpufreq_val = clip_freq;
- notify_device = cpufreq_device;
for_each_cpu(cpuid, mask) {
if (is_cpufreq_valid(cpuid))
cpufreq_update_policy(cpuid);
}
- notify_device = NOTIFY_INVALID;
-
return 0;
}
@@ -316,21 +312,28 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb,
{
struct cpufreq_policy *policy = data;
unsigned long max_freq = 0;
+ struct cpufreq_cooling_device *cpufreq_dev;
- if (event != CPUFREQ_ADJUST || notify_device == NOTIFY_INVALID)
+ if (event != CPUFREQ_ADJUST)
return 0;
- if (cpumask_test_cpu(policy->cpu, &notify_device->allowed_cpus))
- max_freq = notify_device->cpufreq_val;
- else
- return 0;
+ mutex_lock(&cooling_cpufreq_lock);
+ list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
+ if (!cpumask_test_cpu(policy->cpu,
+ &cpufreq_dev->allowed_cpus))
+ continue;
+
+ if (!cpufreq_dev->cpufreq_val)
+ cpufreq_dev->cpufreq_val = get_cpu_frequency(
+ cpumask_any(&cpufreq_dev->allowed_cpus),
+ cpufreq_dev->cpufreq_state);
- /* Never exceed user_policy.max */
- if (max_freq > policy->user_policy.max)
- max_freq = policy->user_policy.max;
+ max_freq = cpufreq_dev->cpufreq_val;
- if (policy->max != max_freq)
- cpufreq_verify_within_limits(policy, 0, max_freq);
+ if (policy->max != max_freq)
+ cpufreq_verify_within_limits(policy, 0, max_freq);
+ }
+ mutex_unlock(&cooling_cpufreq_lock);
return 0;
}
@@ -486,6 +489,7 @@ __cpufreq_cooling_register(struct device_node *np,
cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
CPUFREQ_POLICY_NOTIFIER);
cpufreq_dev_count++;
+ list_add(&cpufreq_dev->node, &cpufreq_dev_list);
mutex_unlock(&cooling_cpufreq_lock);
@@ -549,6 +553,7 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
cpufreq_dev = cdev->devdata;
mutex_lock(&cooling_cpufreq_lock);
+ list_del(&cpufreq_dev->node);
cpufreq_dev_count--;
/* Unregister the notifier for the last cpufreq cooling device */
diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c
index 461bf3d..5a1f107 100644
--- a/drivers/thermal/imx_thermal.c
+++ b/drivers/thermal/imx_thermal.c
@@ -459,6 +459,10 @@ static int imx_thermal_probe(struct platform_device *pdev)
int measure_freq;
int ret;
+ if (!cpufreq_get_current_driver()) {
+ dev_dbg(&pdev->dev, "no cpufreq driver!");
+ return -EPROBE_DEFER;
+ }
data = devm_kzalloc(&pdev->dev, sizeof(*data), GFP_KERNEL);
if (!data)
return -ENOMEM;
@@ -521,6 +525,30 @@ static int imx_thermal_probe(struct platform_device *pdev)
return ret;
}
+ data->thermal_clk = devm_clk_get(&pdev->dev, NULL);
+ if (IS_ERR(data->thermal_clk)) {
+ ret = PTR_ERR(data->thermal_clk);
+ if (ret != -EPROBE_DEFER)
+ dev_err(&pdev->dev,
+ "failed to get thermal clk: %d\n", ret);
+ cpufreq_cooling_unregister(data->cdev);
+ return ret;
+ }
+
+ /*
+ * Thermal sensor needs clk on to get correct value, normally
+ * we should enable its clk before taking measurement and disable
+ * clk after measurement is done, but if alarm function is enabled,
+ * hardware will auto measure the temperature periodically, so we
+ * need to keep the clk always on for alarm function.
+ */
+ ret = clk_prepare_enable(data->thermal_clk);
+ if (ret) {
+ dev_err(&pdev->dev, "failed to enable thermal clk: %d\n", ret);
+ cpufreq_cooling_unregister(data->cdev);
+ return ret;
+ }
+
data->tz = thermal_zone_device_register("imx_thermal_zone",
IMX_TRIP_NUM,
BIT(IMX_TRIP_PASSIVE), data,
@@ -531,26 +559,11 @@ static int imx_thermal_probe(struct platform_device *pdev)
ret = PTR_ERR(data->tz);
dev_err(&pdev->dev,
"failed to register thermal zone device %d\n", ret);
+ clk_disable_unprepare(data->thermal_clk);
cpufreq_cooling_unregister(data->cdev);
return ret;
}
- data->thermal_clk = devm_clk_get(&pdev->dev, NULL);
- if (IS_ERR(data->thermal_clk)) {
- dev_warn(&pdev->dev, "failed to get thermal clk!\n");
- } else {
- /*
- * Thermal sensor needs clk on to get correct value, normally
- * we should enable its clk before taking measurement and disable
- * clk after measurement is done, but if alarm function is enabled,
- * hardware will auto measure the temperature periodically, so we
- * need to keep the clk always on for alarm function.
- */
- ret = clk_prepare_enable(data->thermal_clk);
- if (ret)
- dev_warn(&pdev->dev, "failed to enable thermal clk: %d\n", ret);
- }
-
/* Enable measurements at ~ 10 Hz */
regmap_write(map, TEMPSENSE1 + REG_CLR, TEMPSENSE1_MEASURE_FREQ);
measure_freq = DIV_ROUND_UP(32768, 10); /* 10 Hz */
diff --git a/drivers/thermal/int340x_thermal/int3403_thermal.c b/drivers/thermal/int340x_thermal/int3403_thermal.c
index d20dba9..6e9fb62 100644
--- a/drivers/thermal/int340x_thermal/int3403_thermal.c
+++ b/drivers/thermal/int340x_thermal/int3403_thermal.c
@@ -92,7 +92,13 @@ static int sys_get_trip_hyst(struct thermal_zone_device *tzone,
if (ACPI_FAILURE(status))
return -EIO;
- *temp = DECI_KELVIN_TO_MILLI_CELSIUS(hyst, KELVIN_OFFSET);
+ /*
+ * Thermal hysteresis represents a temperature difference.
+ * Kelvin and Celsius have same degree size. So the
+ * conversion here between tenths of degree Kelvin unit
+ * and Milli-Celsius unit is just to multiply 100.
+ */
+ *temp = hyst * 100;
return 0;
}
diff --git a/drivers/thermal/samsung/exynos_thermal_common.c b/drivers/thermal/samsung/exynos_thermal_common.c
index 3f5ad25..b6be572 100644
--- a/drivers/thermal/samsung/exynos_thermal_common.c
+++ b/drivers/thermal/samsung/exynos_thermal_common.c
@@ -417,13 +417,10 @@ void exynos_unregister_thermal(struct thermal_sensor_conf *sensor_conf)
th_zone = sensor_conf->pzone_data;
- if (th_zone->therm_dev)
- thermal_zone_device_unregister(th_zone->therm_dev);
+ thermal_zone_device_unregister(th_zone->therm_dev);
- for (i = 0; i < th_zone->cool_dev_size; i++) {
- if (th_zone->cool_dev[i])
- cpufreq_cooling_unregister(th_zone->cool_dev[i]);
- }
+ for (i = 0; i < th_zone->cool_dev_size; ++i)
+ cpufreq_cooling_unregister(th_zone->cool_dev[i]);
dev_info(sensor_conf->dev,
"Exynos: Kernel Thermal management unregistered\n");
diff --git a/drivers/thermal/samsung/exynos_tmu_data.c b/drivers/thermal/samsung/exynos_tmu_data.c
index 2683d28..1724f6c 100644
--- a/drivers/thermal/samsung/exynos_tmu_data.c
+++ b/drivers/thermal/samsung/exynos_tmu_data.c
@@ -264,7 +264,6 @@ struct exynos_tmu_init_data const exynos5250_default_tmu_data = {
static const struct exynos_tmu_registers exynos5260_tmu_registers = {
.triminfo_data = EXYNOS_TMU_REG_TRIMINFO,
.tmu_ctrl = EXYNOS_TMU_REG_CONTROL,
- .tmu_ctrl = EXYNOS_TMU_REG_CONTROL1,
.therm_trip_mode_shift = EXYNOS_TMU_TRIP_MODE_SHIFT,
.therm_trip_mode_mask = EXYNOS_TMU_TRIP_MODE_MASK,
.therm_trip_en_shift = EXYNOS_TMU_THERM_TRIP_EN_SHIFT,
diff --git a/drivers/thermal/samsung/exynos_tmu_data.h b/drivers/thermal/samsung/exynos_tmu_data.h
index 65e2ea6..63de598 100644
--- a/drivers/thermal/samsung/exynos_tmu_data.h
+++ b/drivers/thermal/samsung/exynos_tmu_data.h
@@ -75,7 +75,6 @@
#define EXYNOS_MAX_TRIGGER_PER_REG 4
/* Exynos5260 specific */
-#define EXYNOS_TMU_REG_CONTROL1 0x24
#define EXYNOS5260_TMU_REG_INTEN 0xC0
#define EXYNOS5260_TMU_REG_INTSTAT 0xC4
#define EXYNOS5260_TMU_REG_INTCLEAR 0xC8
diff --git a/drivers/thermal/st/st_thermal.c b/drivers/thermal/st/st_thermal.c
index 90163b3..d1ec580 100644
--- a/drivers/thermal/st/st_thermal.c
+++ b/drivers/thermal/st/st_thermal.c
@@ -275,6 +275,7 @@ int st_thermal_unregister(struct platform_device *pdev)
}
EXPORT_SYMBOL_GPL(st_thermal_unregister);
+#ifdef CONFIG_PM_SLEEP
static int st_thermal_suspend(struct device *dev)
{
struct platform_device *pdev = to_platform_device(dev);
@@ -305,6 +306,8 @@ static int st_thermal_resume(struct device *dev)
return 0;
}
+#endif
+
SIMPLE_DEV_PM_OPS(st_thermal_pm_ops, st_thermal_suspend, st_thermal_resume);
EXPORT_SYMBOL_GPL(st_thermal_pm_ops);