diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
index 7687922..cb5a4b9 100644
--- a/drivers/thermal/cpu_cooling.c
+++ b/drivers/thermal/cpu_cooling.c
@@ -65,6 +65,7 @@ struct cpufreq_cooling_device {
unsigned int cpufreq_state;
unsigned int cpufreq_val;
unsigned int max_level;
+ unsigned int *freq_table; /* In descending order */
struct cpumask allowed_cpus;
struct list_head node;
};
@@ -352,6 +353,20 @@ static struct notifier_block thermal_cpufreq_notifier_block = {
.notifier_call = cpufreq_thermal_notifier,
};
+static unsigned int find_next_max(struct cpufreq_frequency_table *table,
+ unsigned int prev_max)
+{
+ struct cpufreq_frequency_table *pos;
+ unsigned int max = 0;
+
+ cpufreq_for_each_valid_entry(pos, table) {
+ if (pos->frequency > max && pos->frequency < prev_max)
+ max = pos->frequency;
+ }
+
+ return max;
+}
+
/**
* __cpufreq_cooling_register - helper function to create cpufreq cooling device
* @np: a valid struct device_node to the cooling device device tree node
@@ -374,6 +389,7 @@ __cpufreq_cooling_register(struct device_node *np,
struct cpufreq_cooling_device *cpufreq_dev;
char dev_name[THERMAL_NAME_LENGTH];
struct cpufreq_frequency_table *pos, *table;
+ unsigned int freq, i;
int ret;
table = cpufreq_frequency_get_table(cpumask_first(clip_cpus));
@@ -397,6 +413,14 @@ __cpufreq_cooling_register(struct device_node *np,
cpufreq_for_each_valid_entry(pos, table)
cpufreq_dev->max_level++;
+ cpufreq_dev->freq_table = kmalloc(sizeof(*cpufreq_dev->freq_table) *
+ cpufreq_dev->max_level, GFP_KERNEL);
+ if (!cpufreq_dev->freq_table) {
+ return ERR_PTR(-ENOMEM);
+ cool_dev = ERR_PTR(-ENOMEM);
+ goto free_cdev;
+ }
+
/* max_level is an index, not a counter */
cpufreq_dev->max_level--;
@@ -405,7 +429,7 @@ __cpufreq_cooling_register(struct device_node *np,
ret = get_idr(&cpufreq_idr, &cpufreq_dev->id);
if (ret) {
cool_dev = ERR_PTR(ret);
- goto free_cdev;
+ goto free_table;
}
snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
@@ -416,6 +440,18 @@ __cpufreq_cooling_register(struct device_node *np,
if (IS_ERR(cool_dev))
goto remove_idr;
+ /* Fill freq-table in descending order of frequencies */
+ for (i = 0, freq = -1; i <= cpufreq_dev->max_level; i++) {
+ freq = find_next_max(table, freq);
+ cpufreq_dev->freq_table[i] = freq;
+
+ /* Warn for duplicate entries */
+ if (!freq)
+ pr_warn("%s: table has duplicate entries\n", __func__);
+ else
+ pr_debug("%s: freq:%u KHz\n", __func__, freq);
+ }
+
cpufreq_dev->cool_dev = cool_dev;
mutex_lock(&cooling_cpufreq_lock);
@@ -432,6 +468,8 @@ __cpufreq_cooling_register(struct device_node *np,
remove_idr:
release_idr(&cpufreq_idr, cpufreq_dev->id);
+free_table:
+ kfree(cpufreq_dev->freq_table);
free_cdev:
kfree(cpufreq_dev);
@@ -505,6 +543,7 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
thermal_cooling_device_unregister(cpufreq_dev->cool_dev);
release_idr(&cpufreq_idr, cpufreq_dev->id);
+ kfree(cpufreq_dev->freq_table);
kfree(cpufreq_dev);
}
EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister);