summaryrefslogtreecommitdiffstats
path: root/drivers/net/phy/smsc.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/net/phy/smsc.c')
-rw-r--r--drivers/net/phy/smsc.c95
1 files changed, 68 insertions, 27 deletions
diff --git a/drivers/net/phy/smsc.c b/drivers/net/phy/smsc.c
index 88e3991..11f3481 100644
--- a/drivers/net/phy/smsc.c
+++ b/drivers/net/phy/smsc.c
@@ -43,7 +43,31 @@ static int smsc_phy_ack_interrupt(struct phy_device *phydev)
static int smsc_phy_config_init(struct phy_device *phydev)
{
- int rc = phy_read(phydev, MII_LAN83C185_CTRL_STATUS);
+ int rc = phy_read(phydev, MII_LAN83C185_SPECIAL_MODES);
+ if (rc < 0)
+ return rc;
+
+ /* If the SMSC PHY is in power down mode, then set it
+ * in all capable mode before using it.
+ */
+ if ((rc & MII_LAN83C185_MODE_MASK) == MII_LAN83C185_MODE_POWERDOWN) {
+ int timeout = 50000;
+
+ /* set "all capable" mode and reset the phy */
+ rc |= MII_LAN83C185_MODE_ALL;
+ phy_write(phydev, MII_LAN83C185_SPECIAL_MODES, rc);
+ phy_write(phydev, MII_BMCR, BMCR_RESET);
+
+ /* wait end of reset (max 500 ms) */
+ do {
+ udelay(10);
+ if (timeout-- == 0)
+ return -1;
+ rc = phy_read(phydev, MII_BMCR);
+ } while (rc & BMCR_RESET);
+ }
+
+ rc = phy_read(phydev, MII_LAN83C185_CTRL_STATUS);
if (rc < 0)
return rc;
@@ -56,35 +80,52 @@ static int smsc_phy_config_init(struct phy_device *phydev)
return smsc_phy_ack_interrupt (phydev);
}
-static int lan87xx_config_init(struct phy_device *phydev)
+static int lan911x_config_init(struct phy_device *phydev)
{
- /*
- * Make sure the EDPWRDOWN bit is NOT set. Setting this bit on
- * LAN8710/LAN8720 PHY causes the PHY to misbehave, likely due
- * to a bug on the chip.
- *
- * When the system is powered on with the network cable being
- * disconnected all the way until after ifconfig ethX up is
- * issued for the LAN port with this PHY, connecting the cable
- * afterwards does not cause LINK change detection, while the
- * expected behavior is the Link UP being detected.
- */
- int rc = phy_read(phydev, MII_LAN83C185_CTRL_STATUS);
- if (rc < 0)
- return rc;
-
- rc &= ~MII_LAN83C185_EDPWRDOWN;
-
- rc = phy_write(phydev, MII_LAN83C185_CTRL_STATUS, rc);
- if (rc < 0)
- return rc;
-
return smsc_phy_ack_interrupt(phydev);
}
-static int lan911x_config_init(struct phy_device *phydev)
+/*
+ * The LAN8710/LAN8720 requires a minimum of 2 link pulses within 64ms of each
+ * other in order to set the ENERGYON bit and exit EDPD mode. If a link partner
+ * does send the pulses within this interval, the PHY will remained powered
+ * down.
+ *
+ * This workaround will manually toggle the PHY on/off upon calls to read_status
+ * in order to generate link test pulses if the link is down. If a link partner
+ * is present, it will respond to the pulses, which will cause the ENERGYON bit
+ * to be set and will cause the EDPD mode to be exited.
+ */
+static int lan87xx_read_status(struct phy_device *phydev)
{
- return smsc_phy_ack_interrupt(phydev);
+ int err = genphy_read_status(phydev);
+
+ if (!phydev->link) {
+ /* Disable EDPD to wake up PHY */
+ int rc = phy_read(phydev, MII_LAN83C185_CTRL_STATUS);
+ if (rc < 0)
+ return rc;
+
+ rc = phy_write(phydev, MII_LAN83C185_CTRL_STATUS,
+ rc & ~MII_LAN83C185_EDPWRDOWN);
+ if (rc < 0)
+ return rc;
+
+ /* Sleep 64 ms to allow ~5 link test pulses to be sent */
+ msleep(64);
+
+ /* Re-enable EDPD */
+ rc = phy_read(phydev, MII_LAN83C185_CTRL_STATUS);
+ if (rc < 0)
+ return rc;
+
+ rc = phy_write(phydev, MII_LAN83C185_CTRL_STATUS,
+ rc | MII_LAN83C185_EDPWRDOWN);
+ if (rc < 0)
+ return rc;
+ }
+
+ return err;
}
static struct phy_driver smsc_phy_driver[] = {
@@ -187,8 +228,8 @@ static struct phy_driver smsc_phy_driver[] = {
/* basic functions */
.config_aneg = genphy_config_aneg,
- .read_status = genphy_read_status,
- .config_init = lan87xx_config_init,
+ .read_status = lan87xx_read_status,
+ .config_init = smsc_phy_config_init,
/* IRQ related */
.ack_interrupt = smsc_phy_ack_interrupt,
OpenPOWER on IntegriCloud