summaryrefslogtreecommitdiffstats
path: root/drivers/net/ethernet/intel/igb/e1000_phy.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/net/ethernet/intel/igb/e1000_phy.c')
-rw-r--r--drivers/net/ethernet/intel/igb/e1000_phy.c49
1 files changed, 37 insertions, 12 deletions
diff --git a/drivers/net/ethernet/intel/igb/e1000_phy.c b/drivers/net/ethernet/intel/igb/e1000_phy.c
index 3404bc7..fe76004 100644
--- a/drivers/net/ethernet/intel/igb/e1000_phy.c
+++ b/drivers/net/ethernet/intel/igb/e1000_phy.c
@@ -1207,20 +1207,25 @@ s32 igb_phy_force_speed_duplex_m88(struct e1000_hw *hw)
u16 phy_data;
bool link;
- /*
- * Clear Auto-Crossover to force MDI manually. M88E1000 requires MDI
- * forced whenever speed and duplex are forced.
- */
- ret_val = phy->ops.read_reg(hw, M88E1000_PHY_SPEC_CTRL, &phy_data);
- if (ret_val)
- goto out;
+ /* I210 and I211 devices support Auto-Crossover in forced operation. */
+ if (phy->type != e1000_phy_i210) {
+ /*
+ * Clear Auto-Crossover to force MDI manually. M88E1000
+ * requires MDI forced whenever speed and duplex are forced.
+ */
+ ret_val = phy->ops.read_reg(hw, M88E1000_PHY_SPEC_CTRL,
+ &phy_data);
+ if (ret_val)
+ goto out;
- phy_data &= ~M88E1000_PSCR_AUTO_X_MODE;
- ret_val = phy->ops.write_reg(hw, M88E1000_PHY_SPEC_CTRL, phy_data);
- if (ret_val)
- goto out;
+ phy_data &= ~M88E1000_PSCR_AUTO_X_MODE;
+ ret_val = phy->ops.write_reg(hw, M88E1000_PHY_SPEC_CTRL,
+ phy_data);
+ if (ret_val)
+ goto out;
- hw_dbg("M88E1000 PSCR: %X\n", phy_data);
+ hw_dbg("M88E1000 PSCR: %X\n", phy_data);
+ }
ret_val = phy->ops.read_reg(hw, PHY_CONTROL, &phy_data);
if (ret_val)
@@ -1710,6 +1715,26 @@ s32 igb_get_cable_length_m88_gen2(struct e1000_hw *hw)
switch (hw->phy.id) {
case I210_I_PHY_ID:
+ /* Get cable length from PHY Cable Diagnostics Control Reg */
+ ret_val = phy->ops.read_reg(hw, (0x7 << GS40G_PAGE_SHIFT) +
+ (I347AT4_PCDL + phy->addr),
+ &phy_data);
+ if (ret_val)
+ return ret_val;
+
+ /* Check if the unit of cable length is meters or cm */
+ ret_val = phy->ops.read_reg(hw, (0x7 << GS40G_PAGE_SHIFT) +
+ I347AT4_PCDC, &phy_data2);
+ if (ret_val)
+ return ret_val;
+
+ is_cm = !(phy_data2 & I347AT4_PCDC_CABLE_LENGTH_UNIT);
+
+ /* Populate the phy structure with cable length in meters */
+ phy->min_cable_length = phy_data / (is_cm ? 100 : 1);
+ phy->max_cable_length = phy_data / (is_cm ? 100 : 1);
+ phy->cable_length = phy_data / (is_cm ? 100 : 1);
+ break;
case I347AT4_E_PHY_ID:
/* Remember the original page select and set it to 7 */
ret_val = phy->ops.read_reg(hw, I347AT4_PAGE_SELECT,
OpenPOWER on IntegriCloud