diff --git a/drivers/hwmon/lm80.c b/drivers/hwmon/lm80.c
index 612807c..a2ca055 100644
--- a/drivers/hwmon/lm80.c
+++ b/drivers/hwmon/lm80.c
@@ -304,6 +304,14 @@ static ssize_t show_alarms(struct device *dev, struct device_attribute *attr,
return sprintf(buf, "%u\n", data->alarms);
}
+static ssize_t show_alarm(struct device *dev, struct device_attribute *attr,
+ char *buf)
+{
+ int bitnr = to_sensor_dev_attr(attr)->index;
+ struct lm80_data *data = lm80_update_device(dev);
+ return sprintf(buf, "%u\n", (data->alarms >> bitnr) & 1);
+}
+
static SENSOR_DEVICE_ATTR(in0_min, S_IWUSR | S_IRUGO,
show_in_min, set_in_min, 0);
static SENSOR_DEVICE_ATTR(in1_min, S_IWUSR | S_IRUGO,
@@ -359,6 +367,17 @@ static DEVICE_ATTR(temp1_crit, S_IWUSR | S_IRUGO, show_temp_os_max,
static DEVICE_ATTR(temp1_crit_hyst, S_IWUSR | S_IRUGO, show_temp_os_hyst,
set_temp_os_hyst);
static DEVICE_ATTR(alarms, S_IRUGO, show_alarms, NULL);
+static SENSOR_DEVICE_ATTR(in0_alarm, S_IRUGO, show_alarm, NULL, 0);
+static SENSOR_DEVICE_ATTR(in1_alarm, S_IRUGO, show_alarm, NULL, 1);
+static SENSOR_DEVICE_ATTR(in2_alarm, S_IRUGO, show_alarm, NULL, 2);
+static SENSOR_DEVICE_ATTR(in3_alarm, S_IRUGO, show_alarm, NULL, 3);
+static SENSOR_DEVICE_ATTR(in4_alarm, S_IRUGO, show_alarm, NULL, 4);
+static SENSOR_DEVICE_ATTR(in5_alarm, S_IRUGO, show_alarm, NULL, 5);
+static SENSOR_DEVICE_ATTR(in6_alarm, S_IRUGO, show_alarm, NULL, 6);
+static SENSOR_DEVICE_ATTR(fan1_alarm, S_IRUGO, show_alarm, NULL, 10);
+static SENSOR_DEVICE_ATTR(fan2_alarm, S_IRUGO, show_alarm, NULL, 11);
+static SENSOR_DEVICE_ATTR(temp1_max_alarm, S_IRUGO, show_alarm, NULL, 8);
+static SENSOR_DEVICE_ATTR(temp1_crit_alarm, S_IRUGO, show_alarm, NULL, 13);
/*
* Real code
@@ -405,7 +424,17 @@ static struct attribute *lm80_attributes[] = {
&dev_attr_temp1_crit.attr,
&dev_attr_temp1_crit_hyst.attr,
&dev_attr_alarms.attr,
-
+ &sensor_dev_attr_in0_alarm.dev_attr.attr,
+ &sensor_dev_attr_in1_alarm.dev_attr.attr,
+ &sensor_dev_attr_in2_alarm.dev_attr.attr,
+ &sensor_dev_attr_in3_alarm.dev_attr.attr,
+ &sensor_dev_attr_in4_alarm.dev_attr.attr,
+ &sensor_dev_attr_in5_alarm.dev_attr.attr,
+ &sensor_dev_attr_in6_alarm.dev_attr.attr,
+ &sensor_dev_attr_fan1_alarm.dev_attr.attr,
+ &sensor_dev_attr_fan2_alarm.dev_attr.attr,
+ &sensor_dev_attr_temp1_max_alarm.dev_attr.attr,
+ &sensor_dev_attr_temp1_crit_alarm.dev_attr.attr,
NULL
};