summaryrefslogtreecommitdiffstats
path: root/arch/powerpc/platforms/pseries/eeh.c
diff options
context:
space:
mode:
Diffstat (limited to 'arch/powerpc/platforms/pseries/eeh.c')
-rw-r--r--arch/powerpc/platforms/pseries/eeh.c26
1 files changed, 4 insertions, 22 deletions
diff --git a/arch/powerpc/platforms/pseries/eeh.c b/arch/powerpc/platforms/pseries/eeh.c
index bb6de6c..70a9617 100644
--- a/arch/powerpc/platforms/pseries/eeh.c
+++ b/arch/powerpc/platforms/pseries/eeh.c
@@ -87,7 +87,6 @@
#define PCI_BUS_RESET_WAIT_MSEC (60*1000)
/* RTAS tokens */
-static int ibm_set_eeh_option;
static int ibm_set_slot_reset;
static int ibm_read_slot_reset_state;
static int ibm_read_slot_reset_state2;
@@ -283,7 +282,7 @@ void eeh_slot_error_detail(struct pci_dn *pdn, int severity)
size_t loglen = 0;
pci_regs_buf[0] = 0;
- eeh_pci_enable(pdn, EEH_THAW_MMIO);
+ eeh_pci_enable(pdn, EEH_OPT_THAW_MMIO);
eeh_configure_bridge(pdn);
eeh_restore_bars(pdn);
loglen = eeh_gather_pci_data(pdn, pci_regs_buf, EEH_PCI_REGS_LOG_LEN);
@@ -698,26 +697,15 @@ EXPORT_SYMBOL(eeh_check_failure);
*/
int eeh_pci_enable(struct pci_dn *pdn, int function)
{
- int config_addr;
int rc;
- /* Use PE configuration address, if present */
- config_addr = pdn->eeh_config_addr;
- if (pdn->eeh_pe_config_addr)
- config_addr = pdn->eeh_pe_config_addr;
-
- rc = rtas_call(ibm_set_eeh_option, 4, 1, NULL,
- config_addr,
- BUID_HI(pdn->phb->buid),
- BUID_LO(pdn->phb->buid),
- function);
-
+ rc = eeh_ops->set_option(pdn->node, function);
if (rc)
printk(KERN_WARNING "EEH: Unexpected state change %d, err=%d dn=%s\n",
function, rc, pdn->node->full_name);
rc = eeh_wait_for_slot_status(pdn, PCI_BUS_RESET_WAIT_MSEC);
- if ((rc == 4) && (function == EEH_THAW_MMIO))
+ if ((rc == 4) && (function == EEH_OPT_THAW_MMIO))
return 0;
return rc;
@@ -1158,9 +1146,7 @@ static void *eeh_early_enable(struct device_node *dn, void *data)
if (regs) {
/* First register entry is addr (00BBSS00) */
/* Try to enable eeh */
- ret = rtas_call(ibm_set_eeh_option, 4, 1, NULL,
- regs[0], info->buid_hi, info->buid_lo,
- EEH_ENABLE);
+ ret = eeh_ops->set_option(dn, EEH_OPT_ENABLE);
enable = 0;
if (ret == 0) {
@@ -1299,7 +1285,6 @@ void __init eeh_init(void)
if (np == NULL)
return;
- ibm_set_eeh_option = rtas_token("ibm,set-eeh-option");
ibm_set_slot_reset = rtas_token("ibm,set-slot-reset");
ibm_read_slot_reset_state2 = rtas_token("ibm,read-slot-reset-state2");
ibm_read_slot_reset_state = rtas_token("ibm,read-slot-reset-state");
@@ -1309,9 +1294,6 @@ void __init eeh_init(void)
ibm_configure_bridge = rtas_token("ibm,configure-bridge");
ibm_configure_pe = rtas_token("ibm,configure-pe");
- if (ibm_set_eeh_option == RTAS_UNKNOWN_SERVICE)
- return;
-
eeh_error_buf_size = rtas_token("rtas-error-log-max");
if (eeh_error_buf_size == RTAS_UNKNOWN_SERVICE) {
eeh_error_buf_size = 1024;
OpenPOWER on IntegriCloud