diff options
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r-- | Documentation/hwmon/lm75 | 5 | ||||
-rw-r--r-- | Documentation/hwmon/max31790 | 37 |
2 files changed, 40 insertions, 2 deletions
diff --git a/Documentation/hwmon/lm75 b/Documentation/hwmon/lm75 index 67691a0a..ac95edf 100644 --- a/Documentation/hwmon/lm75 +++ b/Documentation/hwmon/lm75 @@ -42,8 +42,8 @@ Supported chips: Addresses scanned: none Datasheet: Publicly available at the ST website http://www.st.com/internet/analog/product/121769.jsp - * Texas Instruments TMP100, TMP101, TMP105, TMP112, TMP75, TMP175, TMP275 - Prefixes: 'tmp100', 'tmp101', 'tmp105', 'tmp112', 'tmp175', 'tmp75', 'tmp275' + * Texas Instruments TMP100, TMP101, TMP105, TMP112, TMP75, TMP75C, TMP175, TMP275 + Prefixes: 'tmp100', 'tmp101', 'tmp105', 'tmp112', 'tmp175', 'tmp75', 'tmp75c', 'tmp275' Addresses scanned: none Datasheet: Publicly available at the Texas Instruments website http://www.ti.com/product/tmp100 @@ -51,6 +51,7 @@ Supported chips: http://www.ti.com/product/tmp105 http://www.ti.com/product/tmp112 http://www.ti.com/product/tmp75 + http://www.ti.com/product/tmp75c http://www.ti.com/product/tmp175 http://www.ti.com/product/tmp275 * NXP LM75B diff --git a/Documentation/hwmon/max31790 b/Documentation/hwmon/max31790 new file mode 100644 index 0000000..855e624 --- /dev/null +++ b/Documentation/hwmon/max31790 @@ -0,0 +1,37 @@ +Kernel driver max31790 +====================== + +Supported chips: + * Maxim MAX31790 + Prefix: 'max31790' + Addresses scanned: - + Datasheet: http://pdfserv.maximintegrated.com/en/ds/MAX31790.pdf + +Author: Il Han <corone.il.han@gmail.com> + + +Description +----------- + +This driver implements support for the Maxim MAX31790 chip. + +The MAX31790 controls the speeds of up to six fans using six independent +PWM outputs. The desired fan speeds (or PWM duty cycles) are written +through the I2C interface. The outputs drive "4-wire" fans directly, +or can be used to modulate the fan's power terminals using an external +pass transistor. + +Tachometer inputs monitor fan tachometer logic outputs for precise (+/-1%) +monitoring and control of fan RPM as well as detection of fan failure. +Six pins are dedicated tachometer inputs. Any of the six PWM outputs can +also be configured to serve as tachometer inputs. + + +Sysfs entries +------------- + +fan[1-12]_input RO fan tachometer speed in RPM +fan[1-12]_fault RO fan experienced fault +fan[1-6]_target RW desired fan speed in RPM +pwm[1-6]_enable RW regulator mode, 0=disabled, 1=manual mode, 2=rpm mode +pwm[1-6] RW fan target duty cycle (0-255) |