summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/ucd9200
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/hwmon/ucd9200')
-rw-r--r--Documentation/hwmon/ucd920010
1 files changed, 5 insertions, 5 deletions
diff --git a/Documentation/hwmon/ucd9200 b/Documentation/hwmon/ucd9200
index 3c58607..fd7d07b 100644
--- a/Documentation/hwmon/ucd9200
+++ b/Documentation/hwmon/ucd9200
@@ -54,9 +54,9 @@ attributes are read-only.
in1_label "vin".
in1_input Measured voltage. From READ_VIN register.
-in1_min Minumum Voltage. From VIN_UV_WARN_LIMIT register.
+in1_min Minimum Voltage. From VIN_UV_WARN_LIMIT register.
in1_max Maximum voltage. From VIN_OV_WARN_LIMIT register.
-in1_lcrit Critical minumum Voltage. VIN_UV_FAULT_LIMIT register.
+in1_lcrit Critical minimum Voltage. VIN_UV_FAULT_LIMIT register.
in1_crit Critical maximum voltage. From VIN_OV_FAULT_LIMIT register.
in1_min_alarm Voltage low alarm. From VIN_UV_WARNING status.
in1_max_alarm Voltage high alarm. From VIN_OV_WARNING status.
@@ -65,9 +65,9 @@ in1_crit_alarm Voltage critical high alarm. From VIN_OV_FAULT status.
in[2-5]_label "vout[1-4]".
in[2-5]_input Measured voltage. From READ_VOUT register.
-in[2-5]_min Minumum Voltage. From VOUT_UV_WARN_LIMIT register.
+in[2-5]_min Minimum Voltage. From VOUT_UV_WARN_LIMIT register.
in[2-5]_max Maximum voltage. From VOUT_OV_WARN_LIMIT register.
-in[2-5]_lcrit Critical minumum Voltage. VOUT_UV_FAULT_LIMIT register.
+in[2-5]_lcrit Critical minimum Voltage. VOUT_UV_FAULT_LIMIT register.
in[2-5]_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register.
in[2-5]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status.
in[2-5]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
@@ -80,7 +80,7 @@ curr1_input Measured current. From READ_IIN register.
curr[2-5]_label "iout[1-4]".
curr[2-5]_input Measured current. From READ_IOUT register.
curr[2-5]_max Maximum current. From IOUT_OC_WARN_LIMIT register.
-curr[2-5]_lcrit Critical minumum output current. From IOUT_UC_FAULT_LIMIT
+curr[2-5]_lcrit Critical minimum output current. From IOUT_UC_FAULT_LIMIT
register.
curr[2-5]_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register.
curr[2-5]_max_alarm Current high alarm. From IOUT_OC_WARNING status.
OpenPOWER on IntegriCloud