summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/lm25066
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/hwmon/lm25066')
-rw-r--r--Documentation/hwmon/lm2506634
1 files changed, 23 insertions, 11 deletions
diff --git a/Documentation/hwmon/lm25066 b/Documentation/hwmon/lm25066
index 26025e4..c1b57d7 100644
--- a/Documentation/hwmon/lm25066
+++ b/Documentation/hwmon/lm25066
@@ -1,7 +1,13 @@
-Kernel driver max8688
+Kernel driver lm25066
=====================
Supported chips:
+ * TI LM25056
+ Prefix: 'lm25056'
+ Addresses scanned: -
+ Datasheets:
+ http://www.ti.com/lit/gpn/lm25056
+ http://www.ti.com/lit/gpn/lm25056a
* National Semiconductor LM25066
Prefix: 'lm25066'
Addresses scanned: -
@@ -25,8 +31,9 @@ Author: Guenter Roeck <linux@roeck-us.net>
Description
-----------
-This driver supports hardware montoring for National Semiconductor LM25066,
-LM5064, and LM5064 Power Management, Monitoring, Control, and Protection ICs.
+This driver supports hardware montoring for National Semiconductor / TI LM25056,
+LM25066, LM5064, and LM5064 Power Management, Monitoring, Control, and
+Protection ICs.
The driver is a client driver to the core PMBus driver. Please see
Documentation/hwmon/pmbus for details on PMBus client drivers.
@@ -60,14 +67,19 @@ in1_max Maximum input voltage.
in1_min_alarm Input voltage low alarm.
in1_max_alarm Input voltage high alarm.
-in2_label "vout1"
-in2_input Measured output voltage.
-in2_average Average measured output voltage.
-in2_min Minimum output voltage.
-in2_min_alarm Output voltage low alarm.
-
-in3_label "vout2"
-in3_input Measured voltage on vaux pin
+in2_label "vmon"
+in2_input Measured voltage on VAUX pin
+in2_min Minimum VAUX voltage (LM25056 only).
+in2_max Maximum VAUX voltage (LM25056 only).
+in2_min_alarm VAUX voltage low alarm (LM25056 only).
+in2_max_alarm VAUX voltage high alarm (LM25056 only).
+
+in3_label "vout1"
+ Not supported on LM25056.
+in3_input Measured output voltage.
+in3_average Average measured output voltage.
+in3_min Minimum output voltage.
+in3_min_alarm Output voltage low alarm.
curr1_label "iin"
curr1_input Measured input current.
OpenPOWER on IntegriCloud