summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/jc42
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/hwmon/jc42')
-rw-r--r--Documentation/hwmon/jc4221
1 files changed, 15 insertions, 6 deletions
diff --git a/Documentation/hwmon/jc42 b/Documentation/hwmon/jc42
index 0e76ef1..a22ecf4 100644
--- a/Documentation/hwmon/jc42
+++ b/Documentation/hwmon/jc42
@@ -51,7 +51,8 @@ Supported chips:
* JEDEC JC 42.4 compliant temperature sensor chips
Prefix: 'jc42'
Addresses scanned: I2C 0x18 - 0x1f
- Datasheet: -
+ Datasheet:
+ http://www.jedec.org/sites/default/files/docs/4_01_04R19.pdf
Author:
Guenter Roeck <guenter.roeck@ericsson.com>
@@ -60,7 +61,11 @@ Author:
Description
-----------
-This driver implements support for JEDEC JC 42.4 compliant temperature sensors.
+This driver implements support for JEDEC JC 42.4 compliant temperature sensors,
+which are used on many DDR3 memory modules for mobile devices and servers. Some
+systems use the sensor to prevent memory overheating by automatically throttling
+the memory controller.
+
The driver auto-detects the chips listed above, but can be manually instantiated
to support other JC 42.4 compliant chips.
@@ -81,15 +86,19 @@ limits. The chip supports only a single register to configure the hysteresis,
which applies to all limits. This register can be written by writing into
temp1_crit_hyst. Other hysteresis attributes are read-only.
+If the BIOS has configured the sensor for automatic temperature management, it
+is likely that it has locked the registers, i.e., that the temperature limits
+cannot be changed.
+
Sysfs entries
-------------
temp1_input Temperature (RO)
-temp1_min Minimum temperature (RW)
-temp1_max Maximum temperature (RW)
-temp1_crit Critical high temperature (RW)
+temp1_min Minimum temperature (RO or RW)
+temp1_max Maximum temperature (RO or RW)
+temp1_crit Critical high temperature (RO or RW)
-temp1_crit_hyst Critical hysteresis temperature (RW)
+temp1_crit_hyst Critical hysteresis temperature (RO or RW)
temp1_max_hyst Maximum hysteresis temperature (RO)
temp1_min_alarm Temperature low alarm
OpenPOWER on IntegriCloud