summaryrefslogtreecommitdiffstats
path: root/Documentation/ABI/testing/sysfs-bus-iio-timer-stm32
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/ABI/testing/sysfs-bus-iio-timer-stm32')
-rw-r--r--Documentation/ABI/testing/sysfs-bus-iio-timer-stm3271
1 files changed, 67 insertions, 4 deletions
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-timer-stm32 b/Documentation/ABI/testing/sysfs-bus-iio-timer-stm32
index 6534a60..230020e 100644
--- a/Documentation/ABI/testing/sysfs-bus-iio-timer-stm32
+++ b/Documentation/ABI/testing/sysfs-bus-iio-timer-stm32
@@ -3,11 +3,15 @@ KernelVersion: 4.11
Contact: benjamin.gaignard@st.com
Description:
Reading returns the list possible master modes which are:
- - "reset" : The UG bit from the TIMx_EGR register is used as trigger output (TRGO).
- - "enable" : The Counter Enable signal CNT_EN is used as trigger output.
+ - "reset" : The UG bit from the TIMx_EGR register is
+ used as trigger output (TRGO).
+ - "enable" : The Counter Enable signal CNT_EN is used
+ as trigger output.
- "update" : The update event is selected as trigger output.
- For instance a master timer can then be used as a prescaler for a slave timer.
- - "compare_pulse" : The trigger output send a positive pulse when the CC1IF flag is to be set.
+ For instance a master timer can then be used
+ as a prescaler for a slave timer.
+ - "compare_pulse" : The trigger output send a positive pulse
+ when the CC1IF flag is to be set.
- "OC1REF" : OC1REF signal is used as trigger output.
- "OC2REF" : OC2REF signal is used as trigger output.
- "OC3REF" : OC3REF signal is used as trigger output.
@@ -27,3 +31,62 @@ Description:
Reading returns the current sampling frequency.
Writing an value different of 0 set and start sampling.
Writing 0 stop sampling.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_count0_preset
+KernelVersion: 4.12
+Contact: benjamin.gaignard@st.com
+Description:
+ Reading returns the current preset value.
+ Writing sets the preset value.
+ When counting up the counter starts from 0 and fires an
+ event when reach preset value.
+ When counting down the counter start from preset value
+ and fire event when reach 0.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_count_quadrature_mode_available
+KernelVersion: 4.12
+Contact: benjamin.gaignard@st.com
+Description:
+ Reading returns the list possible quadrature modes.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_count0_quadrature_mode
+KernelVersion: 4.12
+Contact: benjamin.gaignard@st.com
+Description:
+ Configure the device counter quadrature modes:
+ channel_A:
+ Encoder A input servers as the count input and B as
+ the UP/DOWN direction control input.
+
+ channel_B:
+ Encoder B input serves as the count input and A as
+ the UP/DOWN direction control input.
+
+ quadrature:
+ Encoder A and B inputs are mixed to get direction
+ and count with a scale of 0.25.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_count_enable_mode_available
+KernelVersion: 4.12
+Contact: benjamin.gaignard@st.com
+Description:
+ Reading returns the list possible enable modes.
+
+What: /sys/bus/iio/devices/iio:deviceX/in_count0_enable_mode
+KernelVersion: 4.12
+Contact: benjamin.gaignard@st.com
+Description:
+ Configure the device counter enable modes, in all case
+ counting direction is set by in_count0_count_direction
+ attribute and the counter is clocked by the internal clock.
+ always:
+ Counter is always ON.
+
+ gated:
+ Counting is enabled when connected trigger signal
+ level is high else counting is disabled.
+
+ triggered:
+ Counting is enabled on rising edge of the connected
+ trigger, and remains enabled for the duration of this
+ selected mode.
OpenPOWER on IntegriCloud