summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
-rw-r--r--fs/notify/fanotify/fanotify.c56
-rw-r--r--include/linux/fsnotify_backend.h2
2 files changed, 47 insertions, 11 deletions
diff --git a/fs/notify/fanotify/fanotify.c b/fs/notify/fanotify/fanotify.c
index aa5e926..202be8a 100644
--- a/fs/notify/fanotify/fanotify.c
+++ b/fs/notify/fanotify/fanotify.c
@@ -2,6 +2,7 @@
#include <linux/fsnotify_backend.h>
#include <linux/init.h>
#include <linux/kernel.h> /* UINT_MAX */
+#include <linux/mount.h>
#include <linux/types.h>
#include "fanotify.h"
@@ -99,24 +100,35 @@ static int fanotify_handle_event(struct fsnotify_group *group, struct fsnotify_e
return ret;
}
-static bool fanotify_should_send_event(struct fsnotify_group *group, struct inode *inode,
- struct vfsmount *mnt, __u32 mask, void *data,
- int data_type)
+static bool should_send_vfsmount_event(struct fsnotify_group *group, struct vfsmount *mnt,
+ __u32 mask)
{
struct fsnotify_mark *fsn_mark;
bool send;
- pr_debug("%s: group=%p inode=%p mask=%x data=%p data_type=%d\n",
- __func__, group, inode, mask, data, data_type);
+ pr_debug("%s: group=%p vfsmount=%p mask=%x\n",
+ __func__, group, mnt, mask);
- /* sorry, fanotify only gives a damn about files and dirs */
- if (!S_ISREG(inode->i_mode) &&
- !S_ISDIR(inode->i_mode))
+ fsn_mark = fsnotify_find_vfsmount_mark(group, mnt);
+ if (!fsn_mark)
return false;
- /* if we don't have enough info to send an event to userspace say no */
- if (data_type != FSNOTIFY_EVENT_PATH)
- return false;
+ send = (mask & fsn_mark->mask);
+
+ /* find took a reference */
+ fsnotify_put_mark(fsn_mark);
+
+ return send;
+}
+
+static bool should_send_inode_event(struct fsnotify_group *group, struct inode *inode,
+ __u32 mask)
+{
+ struct fsnotify_mark *fsn_mark;
+ bool send;
+
+ pr_debug("%s: group=%p inode=%p mask=%x\n",
+ __func__, group, inode, mask);
fsn_mark = fsnotify_find_inode_mark(group, inode);
if (!fsn_mark)
@@ -142,6 +154,28 @@ static bool fanotify_should_send_event(struct fsnotify_group *group, struct inod
return send;
}
+static bool fanotify_should_send_event(struct fsnotify_group *group, struct inode *to_tell,
+ struct vfsmount *mnt, __u32 mask, void *data,
+ int data_type)
+{
+ pr_debug("%s: group=%p to_tell=%p mnt=%p mask=%x data=%p data_type=%d\n",
+ __func__, group, to_tell, mnt, mask, data, data_type);
+
+ /* sorry, fanotify only gives a damn about files and dirs */
+ if (!S_ISREG(to_tell->i_mode) &&
+ !S_ISDIR(to_tell->i_mode))
+ return false;
+
+ /* if we don't have enough info to send an event to userspace say no */
+ if (data_type != FSNOTIFY_EVENT_PATH)
+ return false;
+
+ if (mnt)
+ return should_send_vfsmount_event(group, mnt, mask);
+ else
+ return should_send_inode_event(group, to_tell, mask);
+}
+
const struct fsnotify_ops fanotify_fsnotify_ops = {
.handle_event = fanotify_handle_event,
.should_send_event = fanotify_should_send_event,
diff --git a/include/linux/fsnotify_backend.h b/include/linux/fsnotify_backend.h
index 1af42cb..2d2f015 100644
--- a/include/linux/fsnotify_backend.h
+++ b/include/linux/fsnotify_backend.h
@@ -368,6 +368,8 @@ extern void fsnotify_recalc_inode_mask(struct inode *inode);
extern void fsnotify_init_mark(struct fsnotify_mark *mark, void (*free_mark)(struct fsnotify_mark *mark));
/* find (and take a reference) to a mark associated with group and inode */
extern struct fsnotify_mark *fsnotify_find_inode_mark(struct fsnotify_group *group, struct inode *inode);
+/* find (and take a reference) to a mark associated with group and vfsmount */
+extern struct fsnotify_mark *fsnotify_find_vfsmount_mark(struct fsnotify_group *group, struct vfsmount *mnt);
/* copy the values from old into new */
extern void fsnotify_duplicate_mark(struct fsnotify_mark *new, struct fsnotify_mark *old);
/* attach the mark to both the group and the inode */
OpenPOWER on IntegriCloud