summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
-rw-r--r--include/linux/hrtimer.h2
-rw-r--r--kernel/hrtimer.c4
-rw-r--r--kernel/time/clocksource.c18
3 files changed, 20 insertions, 4 deletions
diff --git a/include/linux/hrtimer.h b/include/linux/hrtimer.h
index 0d2f7c8..58021b0 100644
--- a/include/linux/hrtimer.h
+++ b/include/linux/hrtimer.h
@@ -305,7 +305,7 @@ static inline int hrtimer_is_hres_active(struct hrtimer *timer)
extern ktime_t ktime_get(void);
extern ktime_t ktime_get_real(void);
-
+extern int hrtimer_hres_active(void);
DECLARE_PER_CPU(struct tick_device, tick_cpu_device);
diff --git a/kernel/hrtimer.c b/kernel/hrtimer.c
index cb8a15c..1a70c18 100644
--- a/kernel/hrtimer.c
+++ b/kernel/hrtimer.c
@@ -476,7 +476,7 @@ static inline int hrtimer_is_hres_enabled(void)
/*
* Is the high resolution mode active ?
*/
-static inline int hrtimer_hres_active(void)
+int hrtimer_hres_active(void)
{
return __get_cpu_var(hrtimer_bases).hres_active;
}
@@ -704,7 +704,7 @@ static int hrtimer_switch_to_hres(void)
#else
-static inline int hrtimer_hres_active(void) { return 0; }
+int hrtimer_hres_active(void) { return 0; }
static inline int hrtimer_is_hres_enabled(void) { return 0; }
static inline int hrtimer_switch_to_hres(void) { return 0; }
static inline void hrtimer_force_reprogram(struct hrtimer_cpu_base *base) { }
diff --git a/kernel/time/clocksource.c b/kernel/time/clocksource.c
index 80189f6..18b9f5d 100644
--- a/kernel/time/clocksource.c
+++ b/kernel/time/clocksource.c
@@ -30,6 +30,7 @@
#include <linux/module.h>
#include <linux/sched.h> /* for spin_unlock_irq() using preempt_count() m68k */
#include <linux/tick.h>
+#include <linux/hrtimer.h>
void timecounter_init(struct timecounter *tc,
const struct cyclecounter *cc,
@@ -509,6 +510,18 @@ static ssize_t sysfs_override_clocksource(struct sys_device *dev,
}
}
+ /*
+ * Check to make sure we don't switch to a non-HRT usable
+ * clocksource if HRT is enabled and running
+ */
+ if (hrtimer_hres_active() &&
+ !(ovr->flags & CLOCK_SOURCE_VALID_FOR_HRES)) {
+ printk(KERN_WARNING "%s clocksource is not HRT compatible. "
+ "Cannot switch while in HRT mode\n", ovr->name);
+ ovr = NULL;
+ override_name[0] = 0;
+ }
+
/* Reselect, when the override name has changed */
if (ovr != clocksource_override) {
clocksource_override = ovr;
@@ -537,7 +550,10 @@ sysfs_show_available_clocksources(struct sys_device *dev,
spin_lock_irq(&clocksource_lock);
list_for_each_entry(src, &clocksource_list, list) {
- count += snprintf(buf + count,
+ /* Don't show non-HRES clocksource if HRES is enabled */
+ if (!hrtimer_hres_active() ||
+ (src->flags & CLOCK_SOURCE_VALID_FOR_HRES))
+ count += snprintf(buf + count,
max((ssize_t)PAGE_SIZE - count, (ssize_t)0),
"%s ", src->name);
}
OpenPOWER on IntegriCloud