summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
-rw-r--r--include/linux/sched.h8
-rw-r--r--kernel/sched.c83
2 files changed, 61 insertions, 30 deletions
diff --git a/include/linux/sched.h b/include/linux/sched.h
index 15ab3e0..3d95c48 100644
--- a/include/linux/sched.h
+++ b/include/linux/sched.h
@@ -680,8 +680,14 @@ struct sched_group {
/*
* CPU power of this group, SCHED_LOAD_SCALE being max power for a
* single CPU. This is read only (except for setup, hotplug CPU).
+ * Note : Never change cpu_power without recompute its reciprocal
*/
- unsigned long cpu_power;
+ unsigned int __cpu_power;
+ /*
+ * reciprocal value of cpu_power to avoid expensive divides
+ * (see include/linux/reciprocal_div.h)
+ */
+ u32 reciprocal_cpu_power;
};
struct sched_domain {
diff --git a/kernel/sched.c b/kernel/sched.c
index 7459928..e4a5888 100644
--- a/kernel/sched.c
+++ b/kernel/sched.c
@@ -52,8 +52,9 @@
#include <linux/tsacct_kern.h>
#include <linux/kprobes.h>
#include <linux/delayacct.h>
-#include <asm/tlb.h>
+#include <linux/reciprocal_div.h>
+#include <asm/tlb.h>
#include <asm/unistd.h>
/*
@@ -181,6 +182,27 @@ static unsigned int static_prio_timeslice(int static_prio)
return SCALE_PRIO(DEF_TIMESLICE, static_prio);
}
+#ifdef CONFIG_SMP
+/*
+ * Divide a load by a sched group cpu_power : (load / sg->__cpu_power)
+ * Since cpu_power is a 'constant', we can use a reciprocal divide.
+ */
+static inline u32 sg_div_cpu_power(const struct sched_group *sg, u32 load)
+{
+ return reciprocal_divide(load, sg->reciprocal_cpu_power);
+}
+
+/*
+ * Each time a sched group cpu_power is changed,
+ * we must compute its reciprocal value
+ */
+static inline void sg_inc_cpu_power(struct sched_group *sg, u32 val)
+{
+ sg->__cpu_power += val;
+ sg->reciprocal_cpu_power = reciprocal_value(sg->__cpu_power);
+}
+#endif
+
/*
* task_timeslice() scales user-nice values [ -20 ... 0 ... 19 ]
* to time slice values: [800ms ... 100ms ... 5ms]
@@ -1256,7 +1278,8 @@ find_idlest_group(struct sched_domain *sd, struct task_struct *p, int this_cpu)
}
/* Adjust by relative CPU power of the group */
- avg_load = (avg_load * SCHED_LOAD_SCALE) / group->cpu_power;
+ avg_load = sg_div_cpu_power(group,
+ avg_load * SCHED_LOAD_SCALE);
if (local_group) {
this_load = avg_load;
@@ -2367,12 +2390,13 @@ find_busiest_group(struct sched_domain *sd, int this_cpu,
}
total_load += avg_load;
- total_pwr += group->cpu_power;
+ total_pwr += group->__cpu_power;
/* Adjust by relative CPU power of the group */
- avg_load = (avg_load * SCHED_LOAD_SCALE) / group->cpu_power;
+ avg_load = sg_div_cpu_power(group,
+ avg_load * SCHED_LOAD_SCALE);
- group_capacity = group->cpu_power / SCHED_LOAD_SCALE;
+ group_capacity = group->__cpu_power / SCHED_LOAD_SCALE;
if (local_group) {
this_load = avg_load;
@@ -2483,8 +2507,8 @@ group_next:
max_pull = min(max_load - avg_load, max_load - busiest_load_per_task);
/* How much load to actually move to equalise the imbalance */
- *imbalance = min(max_pull * busiest->cpu_power,
- (avg_load - this_load) * this->cpu_power)
+ *imbalance = min(max_pull * busiest->__cpu_power,
+ (avg_load - this_load) * this->__cpu_power)
/ SCHED_LOAD_SCALE;
/*
@@ -2518,28 +2542,29 @@ small_imbalance:
* moving them.
*/
- pwr_now += busiest->cpu_power *
- min(busiest_load_per_task, max_load);
- pwr_now += this->cpu_power *
- min(this_load_per_task, this_load);
+ pwr_now += busiest->__cpu_power *
+ min(busiest_load_per_task, max_load);
+ pwr_now += this->__cpu_power *
+ min(this_load_per_task, this_load);
pwr_now /= SCHED_LOAD_SCALE;
/* Amount of load we'd subtract */
- tmp = busiest_load_per_task * SCHED_LOAD_SCALE /
- busiest->cpu_power;
+ tmp = sg_div_cpu_power(busiest,
+ busiest_load_per_task * SCHED_LOAD_SCALE);
if (max_load > tmp)
- pwr_move += busiest->cpu_power *
+ pwr_move += busiest->__cpu_power *
min(busiest_load_per_task, max_load - tmp);
/* Amount of load we'd add */
- if (max_load * busiest->cpu_power <
+ if (max_load * busiest->__cpu_power <
busiest_load_per_task * SCHED_LOAD_SCALE)
- tmp = max_load * busiest->cpu_power / this->cpu_power;
+ tmp = sg_div_cpu_power(this,
+ max_load * busiest->__cpu_power);
else
- tmp = busiest_load_per_task * SCHED_LOAD_SCALE /
- this->cpu_power;
- pwr_move += this->cpu_power *
- min(this_load_per_task, this_load + tmp);
+ tmp = sg_div_cpu_power(this,
+ busiest_load_per_task * SCHED_LOAD_SCALE);
+ pwr_move += this->__cpu_power *
+ min(this_load_per_task, this_load + tmp);
pwr_move /= SCHED_LOAD_SCALE;
/* Move if we gain throughput */
@@ -5501,7 +5526,7 @@ static void sched_domain_debug(struct sched_domain *sd, int cpu)
break;
}
- if (!group->cpu_power) {
+ if (!group->__cpu_power) {
printk("\n");
printk(KERN_ERR "ERROR: domain->cpu_power not "
"set\n");
@@ -5678,7 +5703,7 @@ init_sched_build_groups(cpumask_t span, const cpumask_t *cpu_map,
continue;
sg->cpumask = CPU_MASK_NONE;
- sg->cpu_power = 0;
+ sg->__cpu_power = 0;
for_each_cpu_mask(j, span) {
if (group_fn(j, cpu_map, NULL) != group)
@@ -6367,7 +6392,7 @@ next_sg:
continue;
}
- sg->cpu_power += sd->groups->cpu_power;
+ sg_inc_cpu_power(sg, sd->groups->__cpu_power);
}
sg = sg->next;
if (sg != group_head)
@@ -6442,6 +6467,8 @@ static void init_sched_groups_power(int cpu, struct sched_domain *sd)
child = sd->child;
+ sd->groups->__cpu_power = 0;
+
/*
* For perf policy, if the groups in child domain share resources
* (for example cores sharing some portions of the cache hierarchy
@@ -6452,18 +6479,16 @@ static void init_sched_groups_power(int cpu, struct sched_domain *sd)
if (!child || (!(sd->flags & SD_POWERSAVINGS_BALANCE) &&
(child->flags &
(SD_SHARE_CPUPOWER | SD_SHARE_PKG_RESOURCES)))) {
- sd->groups->cpu_power = SCHED_LOAD_SCALE;
+ sg_inc_cpu_power(sd->groups, SCHED_LOAD_SCALE);
return;
}
- sd->groups->cpu_power = 0;
-
/*
* add cpu_power of each child group to this groups cpu_power
*/
group = child->groups;
do {
- sd->groups->cpu_power += group->cpu_power;
+ sg_inc_cpu_power(sd->groups, group->__cpu_power);
group = group->next;
} while (group != child->groups);
}
@@ -6623,7 +6648,7 @@ static int build_sched_domains(const cpumask_t *cpu_map)
sd = &per_cpu(node_domains, j);
sd->groups = sg;
}
- sg->cpu_power = 0;
+ sg->__cpu_power = 0;
sg->cpumask = nodemask;
sg->next = sg;
cpus_or(covered, covered, nodemask);
@@ -6651,7 +6676,7 @@ static int build_sched_domains(const cpumask_t *cpu_map)
"Can not alloc domain group for node %d\n", j);
goto error;
}
- sg->cpu_power = 0;
+ sg->__cpu_power = 0;
sg->cpumask = tmp;
sg->next = prev->next;
cpus_or(covered, covered, tmp);
OpenPOWER on IntegriCloud