summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
-rw-r--r--Documentation/devicetree/bindings/thermal/armada-thermal.txt3
-rw-r--r--drivers/thermal/armada_thermal.c30
2 files changed, 32 insertions, 1 deletions
diff --git a/Documentation/devicetree/bindings/thermal/armada-thermal.txt b/Documentation/devicetree/bindings/thermal/armada-thermal.txt
index 2a67e51..4cf0249 100644
--- a/Documentation/devicetree/bindings/thermal/armada-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/armada-thermal.txt
@@ -1,4 +1,4 @@
-* Marvell Armada 370/375/XP thermal management
+* Marvell Armada 370/375/380/XP thermal management
Required properties:
@@ -6,6 +6,7 @@ Required properties:
marvell,armada370-thermal
marvell,armada375-thermal
marvell,armada375-z1-thermal
+ marvell,armada380-thermal
marvell,armadaxp-thermal
Note: As the name suggests, "marvell,armada375-z1-thermal"
diff --git a/drivers/thermal/armada_thermal.c b/drivers/thermal/armada_thermal.c
index e65c5e4..9d1420a 100644
--- a/drivers/thermal/armada_thermal.c
+++ b/drivers/thermal/armada_thermal.c
@@ -43,6 +43,7 @@
#define A375_UNIT_CONTROL_MASK 0x7
#define A375_READOUT_INVERT BIT(15)
#define A375_HW_RESETn BIT(8)
+#define A380_HW_RESET BIT(8)
struct armada_thermal_data;
@@ -149,6 +150,19 @@ static void armada375_init_sensor(struct platform_device *pdev,
mdelay(50);
}
+static void armada380_init_sensor(struct platform_device *pdev,
+ struct armada_thermal_priv *priv)
+{
+ unsigned long reg = readl_relaxed(priv->control);
+
+ /* Reset hardware once */
+ if (!(reg & A380_HW_RESET)) {
+ reg |= A380_HW_RESET;
+ writel(reg, priv->control);
+ mdelay(10);
+ }
+}
+
static bool armada_is_valid(struct armada_thermal_priv *priv)
{
unsigned long reg = readl_relaxed(priv->sensor);
@@ -220,6 +234,18 @@ static const struct armada_thermal_data armada375_data = {
.coef_div = 13616,
};
+static const struct armada_thermal_data armada380_data = {
+ .is_valid = armada_is_valid,
+ .init_sensor = armada380_init_sensor,
+ .is_valid_shift = 10,
+ .temp_shift = 0,
+ .temp_mask = 0x3ff,
+ .coef_b = 1169498786UL,
+ .coef_m = 2000000UL,
+ .coef_div = 4289,
+ .inverted = true,
+};
+
static const struct of_device_id armada_thermal_id_table[] = {
{
.compatible = "marvell,armadaxp-thermal",
@@ -238,6 +264,10 @@ static const struct of_device_id armada_thermal_id_table[] = {
.data = &armada375_data,
},
{
+ .compatible = "marvell,armada380-thermal",
+ .data = &armada380_data,
+ },
+ {
/* sentinel */
},
};
OpenPOWER on IntegriCloud