summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
-rw-r--r--drivers/ata/pata_serverworks.c45
1 files changed, 12 insertions, 33 deletions
diff --git a/drivers/ata/pata_serverworks.c b/drivers/ata/pata_serverworks.c
index 86dd714e..e49365f 100644
--- a/drivers/ata/pata_serverworks.c
+++ b/drivers/ata/pata_serverworks.c
@@ -65,7 +65,8 @@ static const char *csb_bad_ata100[] = {
* bits of the subsystem ID.
*/
-static int dell_cable(struct ata_port *ap) {
+static int dell_cable(struct ata_port *ap)
+{
struct pci_dev *pdev = to_pci_dev(ap->host->dev);
if (pdev->subsystem_device & (1 << (ap->port_no + 14)))
@@ -82,7 +83,8 @@ static int dell_cable(struct ata_port *ap) {
* need to extend the Dell one in future
*/
-static int sun_cable(struct ata_port *ap) {
+static int sun_cable(struct ata_port *ap)
+{
struct pci_dev *pdev = to_pci_dev(ap->host->dev);
if (pdev->subsystem_device & (1 << (ap->port_no + 14)))
@@ -90,29 +92,6 @@ static int sun_cable(struct ata_port *ap) {
return ATA_CBL_PATA40;
}
-/**
- * osb4_cable - OSB4 cable detect
- * @ap: ATA port to check
- *
- * The OSB4 isn't UDMA66 capable so this is easy
- */
-
-static int osb4_cable(struct ata_port *ap) {
- return ATA_CBL_PATA40;
-}
-
-/**
- * csb_cable - CSB5/6 cable detect
- * @ap: ATA port to check
- *
- * Serverworks default arrangement is to use the drive side detection
- * only.
- */
-
-static int csb_cable(struct ata_port *ap) {
- return ATA_CBL_PATA_UNK;
-}
-
struct sv_cable_table {
int device;
int subvendor;
@@ -125,14 +104,14 @@ struct sv_cable_table {
*/
static struct sv_cable_table cable_detect[] = {
- { PCI_DEVICE_ID_SERVERWORKS_CSB5IDE, PCI_VENDOR_ID_DELL, dell_cable },
- { PCI_DEVICE_ID_SERVERWORKS_CSB6IDE, PCI_VENDOR_ID_DELL, dell_cable },
- { PCI_DEVICE_ID_SERVERWORKS_CSB5IDE, PCI_VENDOR_ID_SUN, sun_cable },
- { PCI_DEVICE_ID_SERVERWORKS_OSB4IDE, PCI_ANY_ID, osb4_cable },
- { PCI_DEVICE_ID_SERVERWORKS_CSB5IDE, PCI_ANY_ID, csb_cable },
- { PCI_DEVICE_ID_SERVERWORKS_CSB6IDE, PCI_ANY_ID, csb_cable },
- { PCI_DEVICE_ID_SERVERWORKS_CSB6IDE2, PCI_ANY_ID, csb_cable },
- { PCI_DEVICE_ID_SERVERWORKS_HT1000IDE, PCI_ANY_ID, csb_cable },
+ { PCI_DEVICE_ID_SERVERWORKS_CSB5IDE, PCI_VENDOR_ID_DELL, dell_cable },
+ { PCI_DEVICE_ID_SERVERWORKS_CSB6IDE, PCI_VENDOR_ID_DELL, dell_cable },
+ { PCI_DEVICE_ID_SERVERWORKS_CSB5IDE, PCI_VENDOR_ID_SUN, sun_cable },
+ { PCI_DEVICE_ID_SERVERWORKS_OSB4IDE, PCI_ANY_ID, ata_cable_40wire },
+ { PCI_DEVICE_ID_SERVERWORKS_CSB5IDE, PCI_ANY_ID, ata_cable_unknown },
+ { PCI_DEVICE_ID_SERVERWORKS_CSB6IDE, PCI_ANY_ID, ata_cable_unknown },
+ { PCI_DEVICE_ID_SERVERWORKS_CSB6IDE2, PCI_ANY_ID, ata_cable_unknown },
+ { PCI_DEVICE_ID_SERVERWORKS_HT1000IDE, PCI_ANY_ID, ata_cable_unknown },
{ }
};
OpenPOWER on IntegriCloud