summaryrefslogtreecommitdiffstats
path: root/net/bridge/br_stp.c
diff options
context:
space:
mode:
authorstephen hemminger <shemminger@vyatta.com>2011-03-07 08:34:06 +0000
committerDavid S. Miller <davem@davemloft.net>2011-03-14 14:29:02 -0700
commit1faa4356a3bd89ea11fb92752d897cff3a20ec0e (patch)
tree31bf972b0ee42105bceb79e09f2a8b82d9d9b942 /net/bridge/br_stp.c
parent942527634e201883b39fe0c97a1e47db7a026f91 (diff)
downloadop-kernel-dev-1faa4356a3bd89ea11fb92752d897cff3a20ec0e.zip
op-kernel-dev-1faa4356a3bd89ea11fb92752d897cff3a20ec0e.tar.gz
bridge: control carrier based on ports online
This makes the bridge device behave like a physical device. In earlier releases the bridge always asserted carrier. This changes the behavior so that bridge device carrier is on only if one or more ports are in the forwarding state. This should help IPv6 autoconfiguration, DHCP, and routing daemons. I did brief testing with Network and Virt manager and they seem fine, but since this changes behavior of bridge, it should wait until net-next (2.6.39). Signed-off-by: Stephen Hemminger <shemminger@vyatta.com> Reviewed-by: Nicolas de Pesloüan <nicolas.2p.debian@free.fr> Tested-By: Adam Majer <adamm@zombino.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'net/bridge/br_stp.c')
-rw-r--r--net/bridge/br_stp.c35
1 files changed, 22 insertions, 13 deletions
diff --git a/net/bridge/br_stp.c b/net/bridge/br_stp.c
index 57186d8..a5badd0 100644
--- a/net/bridge/br_stp.c
+++ b/net/bridge/br_stp.c
@@ -397,28 +397,37 @@ static void br_make_forwarding(struct net_bridge_port *p)
void br_port_state_selection(struct net_bridge *br)
{
struct net_bridge_port *p;
+ unsigned int liveports = 0;
/* Don't change port states if userspace is handling STP */
if (br->stp_enabled == BR_USER_STP)
return;
list_for_each_entry(p, &br->port_list, list) {
- if (p->state != BR_STATE_DISABLED) {
- if (p->port_no == br->root_port) {
- p->config_pending = 0;
- p->topology_change_ack = 0;
- br_make_forwarding(p);
- } else if (br_is_designated_port(p)) {
- del_timer(&p->message_age_timer);
- br_make_forwarding(p);
- } else {
- p->config_pending = 0;
- p->topology_change_ack = 0;
- br_make_blocking(p);
- }
+ if (p->state == BR_STATE_DISABLED)
+ continue;
+
+ if (p->port_no == br->root_port) {
+ p->config_pending = 0;
+ p->topology_change_ack = 0;
+ br_make_forwarding(p);
+ } else if (br_is_designated_port(p)) {
+ del_timer(&p->message_age_timer);
+ br_make_forwarding(p);
+ } else {
+ p->config_pending = 0;
+ p->topology_change_ack = 0;
+ br_make_blocking(p);
}
+ if (p->state == BR_STATE_FORWARDING)
+ ++liveports;
}
+
+ if (liveports == 0)
+ netif_carrier_off(br->dev);
+ else
+ netif_carrier_on(br->dev);
}
/* called under bridge lock */
OpenPOWER on IntegriCloud