summaryrefslogtreecommitdiffstats
path: root/net/bluetooth
diff options
context:
space:
mode:
authorAndre Guedes <andre.guedes@openbossa.org>2013-03-27 20:04:55 -0300
committerJohan Hedberg <johan.hedberg@intel.com>2013-04-04 11:12:33 +0300
commit33720450bb811a0cec1f0147bf8a1801113fa94d (patch)
tree1b7e518959f0c0cff850569c2ed40d5084535e80 /net/bluetooth
parent0fc110f4e4f569e12c472f73f0af485e05631403 (diff)
downloadop-kernel-dev-33720450bb811a0cec1f0147bf8a1801113fa94d.zip
op-kernel-dev-33720450bb811a0cec1f0147bf8a1801113fa94d.tar.gz
Bluetooth: Fix HCI request framework
Some HCI commands don't send a Command Complete Event once the HCI command has completed so they require some special handling from the HCI request framework. These HCI commands, however, send a Command Status Event to indicate that the command has been received, and that the controller is currently performing the task for the command. So, in order to properly handle those HCI commands, the HCI request framework should consider the HCI command has completed once the Command Status Event is received. This way, we fix some issues regarding the Inquiry command support, as well as add support for all those HCI commands which would require some special handling from the HCI request framework. Signed-off-by: Andre Guedes <andre.guedes@openbossa.org> Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Diffstat (limited to 'net/bluetooth')
-rw-r--r--net/bluetooth/hci_event.c6
1 files changed, 1 insertions, 5 deletions
diff --git a/net/bluetooth/hci_event.c b/net/bluetooth/hci_event.c
index 1385807..8efb9c0 100644
--- a/net/bluetooth/hci_event.c
+++ b/net/bluetooth/hci_event.c
@@ -53,8 +53,6 @@ static void hci_cc_inquiry_cancel(struct hci_dev *hdev, struct sk_buff *skb)
hci_discovery_set_state(hdev, DISCOVERY_STOPPED);
hci_dev_unlock(hdev);
- hci_req_cmd_complete(hdev, HCI_OP_INQUIRY, status);
-
hci_conn_check_pending(hdev);
}
@@ -1600,8 +1598,6 @@ static void hci_inquiry_complete_evt(struct hci_dev *hdev, struct sk_buff *skb)
BT_DBG("%s status 0x%2.2x", hdev->name, status);
- hci_req_cmd_complete(hdev, HCI_OP_INQUIRY, status);
-
hci_conn_check_pending(hdev);
if (!test_and_clear_bit(HCI_INQUIRY, &hdev->flags))
@@ -2462,7 +2458,7 @@ static void hci_cmd_status_evt(struct hci_dev *hdev, struct sk_buff *skb)
if (opcode != HCI_OP_NOP)
del_timer(&hdev->cmd_timer);
- hci_req_cmd_status(hdev, opcode, ev->status);
+ hci_req_cmd_complete(hdev, opcode, ev->status);
if (ev->ncmd && !test_bit(HCI_RESET, &hdev->flags)) {
atomic_set(&hdev->cmd_cnt, 1);
OpenPOWER on IntegriCloud