summaryrefslogtreecommitdiffstats
path: root/include/linux/sunrpc/rpc_pipe_fs.h
diff options
context:
space:
mode:
authorStanislav Kinsbursky <skinsbursky@parallels.com>2012-01-10 16:13:19 +0400
committerTrond Myklebust <Trond.Myklebust@netapp.com>2012-01-31 18:20:27 -0500
commiteee17325f1dfbe004f1475743bab9e3d050d00f5 (patch)
treeca48905e04e88658cff7d1a745a12ac3c04cfd77 /include/linux/sunrpc/rpc_pipe_fs.h
parent4929d1d33fdbe8385cdd49ccd23563e9ff247ff8 (diff)
downloadop-kernel-dev-eee17325f1dfbe004f1475743bab9e3d050d00f5.zip
op-kernel-dev-eee17325f1dfbe004f1475743bab9e3d050d00f5.tar.gz
NFS: idmap PipeFS notifier introduced
v2: 1) Added "nfs_idmap_init" and "nfs_idmap_quit" definitions for kernels built without CONFIG_NFS_V4 option set. This patch subscribes NFS clients to RPC pipefs notifications. Idmap notifier is registering on NFS module load. This notifier callback is responsible for creation/destruction of PipeFS idmap pipe dentry for NFS4 clients. Since ipdmap pipe is created in rpc client pipefs directory, we have make sure, that this directory has been created already. IOW RPC client notifier callback has been called already. To achive this, PipeFS notifier priorities has been introduced (RPC clients notifier priority is greater than NFS idmap one). But this approach gives another problem: unlink for RPC client directory will be called before NFS idmap pipe unlink on UMOUNT event and will fail, because directory is not empty. The solution, introduced in this patch, is to try to remove client directory once again after idmap pipe was unlinked. This looks like ugly hack, so probably it should be replaced in some more elegant way. Note that no locking required in notifier callback because PipeFS superblock pointer is passed as an argument from it's creation or destruction routine and thus we can be sure about it's validity. Signed-off-by: Stanislav Kinsbursky <skinsbursky@parallels.com> Signed-off-by: Trond Myklebust <Trond.Myklebust@netapp.com>
Diffstat (limited to 'include/linux/sunrpc/rpc_pipe_fs.h')
-rw-r--r--include/linux/sunrpc/rpc_pipe_fs.h7
1 files changed, 7 insertions, 0 deletions
diff --git a/include/linux/sunrpc/rpc_pipe_fs.h b/include/linux/sunrpc/rpc_pipe_fs.h
index 0d1f748..ca32ebd 100644
--- a/include/linux/sunrpc/rpc_pipe_fs.h
+++ b/include/linux/sunrpc/rpc_pipe_fs.h
@@ -49,6 +49,11 @@ RPC_I(struct inode *inode)
return container_of(inode, struct rpc_inode, vfs_inode);
}
+enum {
+ SUNRPC_PIPEFS_NFS_PRIO,
+ SUNRPC_PIPEFS_RPC_PRIO,
+};
+
extern int rpc_pipefs_notifier_register(struct notifier_block *);
extern void rpc_pipefs_notifier_unregister(struct notifier_block *);
@@ -78,6 +83,8 @@ extern struct dentry *rpc_create_cache_dir(struct dentry *,
struct cache_detail *);
extern void rpc_remove_cache_dir(struct dentry *);
+extern int rpc_rmdir(struct dentry *dentry);
+
struct rpc_pipe *rpc_mkpipe_data(const struct rpc_pipe_ops *ops, int flags);
void rpc_destroy_pipe_data(struct rpc_pipe *pipe);
extern struct dentry *rpc_mkpipe_dentry(struct dentry *, const char *, void *,
OpenPOWER on IntegriCloud