summaryrefslogtreecommitdiffstats
path: root/include/linux/cpu_cooling.h
diff options
context:
space:
mode:
authorEduardo Valentin <eduardo.valentin@ti.com>2012-11-12 15:58:50 +0000
committerZhang Rui <rui.zhang@intel.com>2012-11-22 15:59:47 +0800
commit3778ff5c709899a29cefe4b3077a926d0e1e9785 (patch)
tree0395210ef0283ddf95bfd8acb9ba062688230df6 /include/linux/cpu_cooling.h
parentdc1956b5f84de7d453ec4d9fe68385fffd689686 (diff)
downloadop-kernel-dev-3778ff5c709899a29cefe4b3077a926d0e1e9785.zip
op-kernel-dev-3778ff5c709899a29cefe4b3077a926d0e1e9785.tar.gz
thermal: cpu cooling: use const parameter while registering
There are predefined cpu_masks that are const data structures. This patch changes the cpu cooling register function so that those const cpu_masks can be used, without compilation warnings. include/linux/cpumask.h * The following particular system cpumasks and operations manage * possible, present, active and online cpus. * * cpu_possible_mask- has bit 'cpu' set iff cpu is populatable * cpu_present_mask - has bit 'cpu' set iff cpu is populated * cpu_online_mask - has bit 'cpu' set iff cpu available to scheduler * cpu_active_mask - has bit 'cpu' set iff cpu available to migration * Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com> Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Diffstat (limited to 'include/linux/cpu_cooling.h')
-rw-r--r--include/linux/cpu_cooling.h4
1 files changed, 2 insertions, 2 deletions
diff --git a/include/linux/cpu_cooling.h b/include/linux/cpu_cooling.h
index 8515301..b30cc79c 100644
--- a/include/linux/cpu_cooling.h
+++ b/include/linux/cpu_cooling.h
@@ -35,7 +35,7 @@
* @clip_cpus: cpumask of cpus where the frequency constraints will happen
*/
struct thermal_cooling_device *cpufreq_cooling_register(
- struct cpumask *clip_cpus);
+ const struct cpumask *clip_cpus);
/**
* cpufreq_cooling_unregister - function to remove cpufreq cooling device.
@@ -44,7 +44,7 @@ struct thermal_cooling_device *cpufreq_cooling_register(
void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev);
#else /* !CONFIG_CPU_THERMAL */
static inline struct thermal_cooling_device *cpufreq_cooling_register(
- struct cpumask *clip_cpus)
+ const struct cpumask *clip_cpus)
{
return NULL;
}
OpenPOWER on IntegriCloud