authorHou Tao <houtao1@huawei.com>2017-04-28 18:35:19 +0800
committerTrond Myklebust <trond.myklebust@primarydata.com>2017-05-05 13:01:32 -0400
commit59b86d85a7a30ba56289cdac83cd66a7dd2adebf (patch)
treea0cbecb6dc4b59e6323fe5236caa37610f1e8223 /fs/nfs
parent5c737cb29977896eb0f373d3adbcdea73b815808 (diff)
downloadop-kernel-dev-59b86d85a7a30ba56289cdac83cd66a7dd2adebf.zip
op-kernel-dev-59b86d85a7a30ba56289cdac83cd66a7dd2adebf.tar.gz
NFS: always treat the invocation of nfs_getattr as cache hit when noac is on
When using 'ls -l' to display a large directory, if noac option is used, in function nfs_getattr() nfs_need_revalidate_inode() will always be true for NFSv3 and the nfs_entry cache of the directory will be flushed. The flush will lead to a fully reread of the directory entries from server. To prevent the unnecessary RPCs, we need to check whether or not the noac option is used, and always report the invocation of nfs_getattr() as cache hit instead cache miss when it's on. Signed-off-by: Hou Tao <houtao1@huawei.com> Signed-off-by: Trond Myklebust <trond.myklebust@primarydata.com>
Diffstat (limited to 'fs/nfs')
-rw-r--r--fs/nfs/inode.c5
1 files changed, 4 insertions, 1 deletions
diff --git a/fs/nfs/inode.c b/fs/nfs/inode.c
index f489a5a..1de93ba 100644
--- a/fs/nfs/inode.c
+++ b/fs/nfs/inode.c
@@ -734,7 +734,10 @@ int nfs_getattr(const struct path *path, struct kstat *stat,
if (need_atime || nfs_need_revalidate_inode(inode)) {
struct nfs_server *server = NFS_SERVER(inode);
- nfs_readdirplus_parent_cache_miss(path->dentry);
+ if (!(server->flags & NFS_MOUNT_NOAC))
+ nfs_readdirplus_parent_cache_miss(path->dentry);
+ else
+ nfs_readdirplus_parent_cache_hit(path->dentry);
err = __nfs_revalidate_inode(server, inode);
} else
nfs_readdirplus_parent_cache_hit(path->dentry);
OpenPOWER on IntegriCloud