summaryrefslogtreecommitdiffstats
path: root/fs/ext4/super.c
diff options
context:
space:
mode:
authorEric Sandeen <sandeen@redhat.com>2007-07-26 10:41:11 -0700
committerLinus Torvalds <torvalds@woody.linux-foundation.org>2007-07-26 11:35:17 -0700
commit780dcdb21170ae8ad3faa640ede249261f216a8c (patch)
treec452df9f27ff6e1df8498f7b53763ef31279b3d0 /fs/ext4/super.c
parent98ac0e53facc851f8bc5110039ab05005c0c4736 (diff)
downloadop-kernel-dev-780dcdb21170ae8ad3faa640ede249261f216a8c.zip
op-kernel-dev-780dcdb21170ae8ad3faa640ede249261f216a8c.tar.gz
fix inode_table test in ext234_check_descriptors
ext[234]_check_descriptors sanity checks block group descriptor geometry at mount time, testing whether the block bitmap, inode bitmap, and inode table reside wholly within the blockgroup. However, the inode table test is off by one so that if the last block in the inode table resides on the last block of the block group, the test incorrectly fails. This is because it tests the last block as (start + length) rather than (start + length - 1). This can be seen by trying to mount a filesystem made such as: mkfs.ext2 -F -b 1024 -m 0 -g 256 -N 3744 fsfile 1024 which yields: EXT2-fs error (device loop0): ext2_check_descriptors: Inode table for group 0 not in group (block 101)! EXT2-fs: group descriptors corrupted! There is a similar bug in e2fsprogs, patch already sent for that. (I wonder if inside(), outside(), and/or in_range() should someday be used in this and other tests throughout the ext filesystems...) Signed-off-by: Eric Sandeen <sandeen@redhat.com> Cc: <linux-ext4@vger.kernel.org> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Diffstat (limited to 'fs/ext4/super.c')
-rw-r--r--fs/ext4/super.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/fs/ext4/super.c b/fs/ext4/super.c
index 75adbb6..4550b83 100644
--- a/fs/ext4/super.c
+++ b/fs/ext4/super.c
@@ -1283,7 +1283,7 @@ static int ext4_check_descriptors (struct super_block * sb)
}
inode_table = ext4_inode_table(sb, gdp);
if (inode_table < first_block ||
- inode_table + sbi->s_itb_per_group > last_block)
+ inode_table + sbi->s_itb_per_group - 1 > last_block)
{
ext4_error (sb, "ext4_check_descriptors",
"Inode table for group %d"
OpenPOWER on IntegriCloud