summaryrefslogtreecommitdiffstats
path: root/fs/cifs/inode.c
diff options
context:
space:
mode:
authorSteve French <smfrench@gmail.com>2012-08-03 08:43:01 -0500
committerSteve French <smfrench@gmail.com>2012-08-19 22:30:00 -0500
commitb7ca69289680cf631fb20b7d436467c4ec1153cd (patch)
tree94c52c03ebf4efa68cb52df5aa60b554cf6cf999 /fs/cifs/inode.c
parent6dab7ede9390d4d937cb89feca932e4fd575d2da (diff)
downloadop-kernel-dev-b7ca69289680cf631fb20b7d436467c4ec1153cd.zip
op-kernel-dev-b7ca69289680cf631fb20b7d436467c4ec1153cd.tar.gz
CIFS: Protect i_nlink from being negative
that can cause warning messages. Pavel had initially suggested a smaller patch around drop_nlink, after a similar problem was discovered NFS. Protecting additional places where nlink is touched was suggested by Jeff Layton and is included in this. Reviewed-by: Pavel Shilovsky <pshilovsky@samba.org> Reviewed-by: Jeff Layton <jlayton@redhat.com> Signed-off-by: Steve French <sfrench@us.ibm.com> Signed-off-by: Steve French <smfrench@gmail.com>
Diffstat (limited to 'fs/cifs/inode.c')
-rw-r--r--fs/cifs/inode.c24
1 files changed, 16 insertions, 8 deletions
diff --git a/fs/cifs/inode.c b/fs/cifs/inode.c
index 7354877..cb79c7e 100644
--- a/fs/cifs/inode.c
+++ b/fs/cifs/inode.c
@@ -124,10 +124,10 @@ cifs_fattr_to_inode(struct inode *inode, struct cifs_fattr *fattr)
{
struct cifsInodeInfo *cifs_i = CIFS_I(inode);
struct cifs_sb_info *cifs_sb = CIFS_SB(inode->i_sb);
- unsigned long oldtime = cifs_i->time;
cifs_revalidate_cache(inode, fattr);
+ spin_lock(&inode->i_lock);
inode->i_atime = fattr->cf_atime;
inode->i_mtime = fattr->cf_mtime;
inode->i_ctime = fattr->cf_ctime;
@@ -148,9 +148,6 @@ cifs_fattr_to_inode(struct inode *inode, struct cifs_fattr *fattr)
else
cifs_i->time = jiffies;
- cFYI(1, "inode 0x%p old_time=%ld new_time=%ld", inode,
- oldtime, cifs_i->time);
-
cifs_i->delete_pending = fattr->cf_flags & CIFS_FATTR_DELETE_PENDING;
cifs_i->server_eof = fattr->cf_eof;
@@ -158,7 +155,6 @@ cifs_fattr_to_inode(struct inode *inode, struct cifs_fattr *fattr)
* Can't safely change the file size here if the client is writing to
* it due to potential races.
*/
- spin_lock(&inode->i_lock);
if (is_size_safe_to_change(cifs_i, fattr->cf_eof)) {
i_size_write(inode, fattr->cf_eof);
@@ -859,12 +855,14 @@ struct inode *cifs_root_iget(struct super_block *sb)
if (rc && tcon->ipc) {
cFYI(1, "ipc connection - fake read inode");
+ spin_lock(&inode->i_lock);
inode->i_mode |= S_IFDIR;
set_nlink(inode, 2);
inode->i_op = &cifs_ipc_inode_ops;
inode->i_fop = &simple_dir_operations;
inode->i_uid = cifs_sb->mnt_uid;
inode->i_gid = cifs_sb->mnt_gid;
+ spin_unlock(&inode->i_lock);
} else if (rc) {
iget_failed(inode);
inode = ERR_PTR(rc);
@@ -1110,6 +1108,15 @@ undo_setattr:
goto out_close;
}
+/* copied from fs/nfs/dir.c with small changes */
+static void
+cifs_drop_nlink(struct inode *inode)
+{
+ spin_lock(&inode->i_lock);
+ if (inode->i_nlink > 0)
+ drop_nlink(inode);
+ spin_unlock(&inode->i_lock);
+}
/*
* If dentry->d_inode is null (usually meaning the cached dentry
@@ -1166,13 +1173,13 @@ retry_std_delete:
psx_del_no_retry:
if (!rc) {
if (inode)
- drop_nlink(inode);
+ cifs_drop_nlink(inode);
} else if (rc == -ENOENT) {
d_drop(dentry);
} else if (rc == -ETXTBSY) {
rc = cifs_rename_pending_delete(full_path, dentry, xid);
if (rc == 0)
- drop_nlink(inode);
+ cifs_drop_nlink(inode);
} else if ((rc == -EACCES) && (dosattr == 0) && inode) {
attrs = kzalloc(sizeof(*attrs), GFP_KERNEL);
if (attrs == NULL) {
@@ -1241,9 +1248,10 @@ cifs_mkdir_qinfo(struct inode *inode, struct dentry *dentry, umode_t mode,
* setting nlink not necessary except in cases where we failed to get it
* from the server or was set bogus
*/
+ spin_lock(&dentry->d_inode->i_lock);
if ((dentry->d_inode) && (dentry->d_inode->i_nlink < 2))
set_nlink(dentry->d_inode, 2);
-
+ spin_unlock(&dentry->d_inode->i_lock);
mode &= ~current_umask();
/* must turn on setgid bit if parent dir has it */
if (inode->i_mode & S_ISGID)
OpenPOWER on IntegriCloud