summaryrefslogtreecommitdiffstats
path: root/fs/cifs/inode.c
diff options
context:
space:
mode:
authorJeff Layton <jlayton@redhat.com>2008-07-12 13:47:59 -0700
committerLinus Torvalds <torvalds@linux-foundation.org>2008-07-12 14:33:42 -0700
commite911d0cc877ff027d5bd09fc33148ab76f0fdf0e (patch)
treec2549fb1caa266f17d25c20e0c499db823578372 /fs/cifs/inode.c
parentd3297a644a0ab784e0c810ceca6bf35a67868ad9 (diff)
downloadop-kernel-dev-e911d0cc877ff027d5bd09fc33148ab76f0fdf0e.zip
op-kernel-dev-e911d0cc877ff027d5bd09fc33148ab76f0fdf0e.tar.gz
cifs: fix inode leak in cifs_get_inode_info_unix
Try this: mount a share with unix extensions create a file on it umount the share You'll get the following message in the ring buffer: VFS: Busy inodes after unmount of cifs. Self-destruct in 5 seconds. Have a nice day... ...the problem is that cifs_get_inode_info_unix is creating and hashing a new inode even when it's going to return error anyway. The first lookup when creating a file returns an error so we end up leaking this inode before we do the actual create. This appears to be a regression caused by commit 0e4bbde94fdc33f5b3d793166b21bf768ca3e098. The following patch seems to fix it for me, and fixes a minor formatting nit as well. Signed-off-by: Jeff Layton <jlayton@redhat.com> Acked-by: Steven French <sfrench@us.ibm.com> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Diffstat (limited to 'fs/cifs/inode.c')
-rw-r--r--fs/cifs/inode.c20
1 files changed, 10 insertions, 10 deletions
diff --git a/fs/cifs/inode.c b/fs/cifs/inode.c
index 722be54..2e904bd 100644
--- a/fs/cifs/inode.c
+++ b/fs/cifs/inode.c
@@ -219,15 +219,15 @@ int cifs_get_inode_info_unix(struct inode **pinode,
rc = CIFSSMBUnixQPathInfo(xid, pTcon, full_path, &find_data,
cifs_sb->local_nls, cifs_sb->mnt_cifs_flags &
CIFS_MOUNT_MAP_SPECIAL_CHR);
- if (rc) {
- if (rc == -EREMOTE && !is_dfs_referral) {
- is_dfs_referral = true;
- cFYI(DBG2, ("DFS ref"));
- /* for DFS, server does not give us real inode data */
- fill_fake_finddataunix(&find_data, sb);
- rc = 0;
- }
- }
+ if (rc == -EREMOTE && !is_dfs_referral) {
+ is_dfs_referral = true;
+ cFYI(DBG2, ("DFS ref"));
+ /* for DFS, server does not give us real inode data */
+ fill_fake_finddataunix(&find_data, sb);
+ rc = 0;
+ } else if (rc)
+ goto cgiiu_exit;
+
num_of_bytes = le64_to_cpu(find_data.NumOfBytes);
end_of_file = le64_to_cpu(find_data.EndOfFile);
@@ -236,7 +236,7 @@ int cifs_get_inode_info_unix(struct inode **pinode,
*pinode = new_inode(sb);
if (*pinode == NULL) {
rc = -ENOMEM;
- goto cgiiu_exit;
+ goto cgiiu_exit;
}
/* Is an i_ino of zero legal? */
/* note ino incremented to unique num in new_inode */
OpenPOWER on IntegriCloud