authorEmmanuel Grumbach <emmanuel.grumbach@intel.com>2013-03-03 14:35:03 +0200
committerJohannes Berg <johannes.berg@intel.com>2013-03-04 13:39:02 +0100
commit2470b36e84a2e680d7a7e3809cbceae5bfae3606 (patch)
tree90c7d1eaba2a2a26ae42f8047ed0684bbcc03d0b /drivers
parent8101a7f0656bf11c385d6e14f52313b19f017e70 (diff)
downloadop-kernel-dev-2470b36e84a2e680d7a7e3809cbceae5bfae3606.zip
op-kernel-dev-2470b36e84a2e680d7a7e3809cbceae5bfae3606.tar.gz
iwlwifi: mvm: don't warn on normal BAR sending
This flow happens when we get a failed single Tx response on an AMPDU queue. In this case, the frame won't be sent any more. So we need to move the window on the recipient side. This is done by a BAR. Now if we are in the following case: 10, 12 and 13 are ACKed and 11 isn't. 10 11 12 13. V X V V Then, 11 will be sent 16 times as an MPDU (as oppsed to A-MPDU). If this failed, we are entering the flow described above. So we need to send a BAR with ssn = 12. But in this case, the scheduler will tell us to free frames up to 13 (included). So, it is perfectly possible to get a failed single Tx response on an AMPDU queue that makes the scheduler's ssn jump by more than 1 single packet. Signed-off-by: Emmanuel Grumbach <emmanuel.grumbach@intel.com> Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Diffstat (limited to 'drivers')
-rw-r--r--drivers/net/wireless/iwlwifi/mvm/tx.c6
1 files changed, 1 insertions, 5 deletions
diff --git a/drivers/net/wireless/iwlwifi/mvm/tx.c b/drivers/net/wireless/iwlwifi/mvm/tx.c
index 6b67ce3..6645efe 100644
--- a/drivers/net/wireless/iwlwifi/mvm/tx.c
+++ b/drivers/net/wireless/iwlwifi/mvm/tx.c
@@ -607,12 +607,8 @@ static void iwl_mvm_rx_tx_cmd_single(struct iwl_mvm *mvm,
/* Single frame failure in an AMPDU queue => send BAR */
if (txq_id >= IWL_FIRST_AMPDU_QUEUE &&
- !(info->flags & IEEE80211_TX_STAT_ACK)) {
- /* there must be only one skb in the skb_list */
- WARN_ON_ONCE(skb_freed > 1 ||
- !skb_queue_empty(&skbs));
+ !(info->flags & IEEE80211_TX_STAT_ACK))
info->flags |= IEEE80211_TX_STAT_AMPDU_NO_BACK;
- }
/* W/A FW bug: seq_ctl is wrong when the queue is flushed */
if (status == TX_STATUS_FAIL_FIFO_FLUSHED) {