summaryrefslogtreecommitdiffstats
path: root/drivers/xen
diff options
context:
space:
mode:
authorKonrad Rzeszutek Wilk <konrad.wilk@oracle.com>2013-11-26 15:05:40 -0500
committerKonrad Rzeszutek Wilk <konrad.wilk@oracle.com>2014-01-03 14:54:18 -0500
commit51c71a3bbaca868043cc45b3ad3786dd48a90235 (patch)
tree65cef69a3d3434393f1c063b8cf138d9a06e3154 /drivers/xen
parent802eee95bde72fd0cd0f3a5b2098375a487d1eda (diff)
downloadop-kernel-dev-51c71a3bbaca868043cc45b3ad3786dd48a90235.zip
op-kernel-dev-51c71a3bbaca868043cc45b3ad3786dd48a90235.tar.gz
xen/pvhvm: If xen_platform_pci=0 is set don't blow up (v4).
The user has the option of disabling the platform driver: 00:02.0 Unassigned class [ff80]: XenSource, Inc. Xen Platform Device (rev 01) which is used to unplug the emulated drivers (IDE, Realtek 8169, etc) and allow the PV drivers to take over. If the user wishes to disable that they can set: xen_platform_pci=0 (in the guest config file) or xen_emul_unplug=never (on the Linux command line) except it does not work properly. The PV drivers still try to load and since the Xen platform driver is not run - and it has not initialized the grant tables, most of the PV drivers stumble upon: input: Xen Virtual Keyboard as /devices/virtual/input/input5 input: Xen Virtual Pointer as /devices/virtual/input/input6M ------------[ cut here ]------------ kernel BUG at /home/konrad/ssd/konrad/linux/drivers/xen/grant-table.c:1206! invalid opcode: 0000 [#1] SMP Modules linked in: xen_kbdfront(+) xenfs xen_privcmd CPU: 6 PID: 1389 Comm: modprobe Not tainted 3.13.0-rc1upstream-00021-ga6c892b-dirty #1 Hardware name: Xen HVM domU, BIOS 4.4-unstable 11/26/2013 RIP: 0010:[<ffffffff813ddc40>] [<ffffffff813ddc40>] get_free_entries+0x2e0/0x300 Call Trace: [<ffffffff8150d9a3>] ? evdev_connect+0x1e3/0x240 [<ffffffff813ddd0e>] gnttab_grant_foreign_access+0x2e/0x70 [<ffffffffa0010081>] xenkbd_connect_backend+0x41/0x290 [xen_kbdfront] [<ffffffffa0010a12>] xenkbd_probe+0x2f2/0x324 [xen_kbdfront] [<ffffffff813e5757>] xenbus_dev_probe+0x77/0x130 [<ffffffff813e7217>] xenbus_frontend_dev_probe+0x47/0x50 [<ffffffff8145e9a9>] driver_probe_device+0x89/0x230 [<ffffffff8145ebeb>] __driver_attach+0x9b/0xa0 [<ffffffff8145eb50>] ? driver_probe_device+0x230/0x230 [<ffffffff8145eb50>] ? driver_probe_device+0x230/0x230 [<ffffffff8145cf1c>] bus_for_each_dev+0x8c/0xb0 [<ffffffff8145e7d9>] driver_attach+0x19/0x20 [<ffffffff8145e260>] bus_add_driver+0x1a0/0x220 [<ffffffff8145f1ff>] driver_register+0x5f/0xf0 [<ffffffff813e55c5>] xenbus_register_driver_common+0x15/0x20 [<ffffffff813e76b3>] xenbus_register_frontend+0x23/0x40 [<ffffffffa0015000>] ? 0xffffffffa0014fff [<ffffffffa001502b>] xenkbd_init+0x2b/0x1000 [xen_kbdfront] [<ffffffff81002049>] do_one_initcall+0x49/0x170 .. snip.. which is hardly nice. This patch fixes this by having each PV driver check for: - if running in PV, then it is fine to execute (as that is their native environment). - if running in HVM, check if user wanted 'xen_emul_unplug=never', in which case bail out and don't load any PV drivers. - if running in HVM, and if PCI device 5853:0001 (xen_platform_pci) does not exist, then bail out and not load PV drivers. - (v2) if running in HVM, and if the user wanted 'xen_emul_unplug=ide-disks', then bail out for all PV devices _except_ the block one. Ditto for the network one ('nics'). - (v2) if running in HVM, and if the user wanted 'xen_emul_unplug=unnecessary' then load block PV driver, and also setup the legacy IDE paths. In (v3) make it actually load PV drivers. Reported-by: Sander Eikelenboom <linux@eikelenboom.it Reported-by: Anthony PERARD <anthony.perard@citrix.com> Reported-and-Tested-by: Fabio Fantoni <fabio.fantoni@m2r.biz> Signed-off-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com> [v2: Add extra logic to handle the myrid ways 'xen_emul_unplug' can be used per Ian and Stefano suggestion] [v3: Make the unnecessary case work properly] [v4: s/disks/ide-disks/ spotted by Fabio] Reviewed-by: Stefano Stabellini <stefano.stabellini@eu.citrix.com> Acked-by: Bjorn Helgaas <bhelgaas@google.com> [for PCI parts] CC: stable@vger.kernel.org
Diffstat (limited to 'drivers/xen')
-rw-r--r--drivers/xen/xenbus/xenbus_probe_frontend.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/xen/xenbus/xenbus_probe_frontend.c b/drivers/xen/xenbus/xenbus_probe_frontend.c
index 129bf84..cb385c1 100644
--- a/drivers/xen/xenbus/xenbus_probe_frontend.c
+++ b/drivers/xen/xenbus/xenbus_probe_frontend.c
@@ -496,7 +496,7 @@ subsys_initcall(xenbus_probe_frontend_init);
#ifndef MODULE
static int __init boot_wait_for_devices(void)
{
- if (xen_hvm_domain() && !xen_platform_pci_unplug)
+ if (!xen_has_pv_devices())
return -ENODEV;
ready_to_wait_for_devices = 1;
OpenPOWER on IntegriCloud