summaryrefslogtreecommitdiffstats
path: root/drivers/tty/serial/8250/8250_core.c
diff options
context:
space:
mode:
authorMurali Karicheri <m-karicheri2@ti.com>2014-05-01 15:04:53 -0400
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2014-05-28 13:04:46 -0700
commit06aa82e498c144c7784a6f3d3b55458b272d6146 (patch)
tree0055d789f294f29287ec4386ef3b81ef9eb4a181 /drivers/tty/serial/8250/8250_core.c
parentab5e4e4108ca5d8326cb6b4b3a21b096a002f68f (diff)
downloadop-kernel-dev-06aa82e498c144c7784a6f3d3b55458b272d6146.zip
op-kernel-dev-06aa82e498c144c7784a6f3d3b55458b272d6146.tar.gz
serial: uart: add hw flow control support configuration
8250 uart driver currently supports only software assisted hw flow control. The software assisted hw flow control maintains a hw_stopped flag in the tty structure to stop and start transmission and use modem status interrupt for the event to drive the handshake signals. This is not needed if hw has flow control capabilities. This patch adds a DT attribute for enabling hw flow control for a uart port. Also skip stop and start if this flag is present in flag field of the port structure. Signed-off-by: Murali Karicheri <m-karicheri2@ti.com> CC: Rob Herring <robh+dt@kernel.org> CC: Pawel Moll <pawel.moll@arm.com> CC: Mark Rutland <mark.rutland@arm.com> CC: Ian Campbell <ijc+devicetree@hellion.org.uk> CC: Kumar Gala <galak@codeaurora.org> CC: Randy Dunlap <rdunlap@infradead.org> CC: Jiri Slaby <jslaby@suse.cz> CC: Santosh Shilimkar <santosh.shilimkar@ti.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'drivers/tty/serial/8250/8250_core.c')
-rw-r--r--drivers/tty/serial/8250/8250_core.c6
1 files changed, 4 insertions, 2 deletions
diff --git a/drivers/tty/serial/8250/8250_core.c b/drivers/tty/serial/8250/8250_core.c
index 111ee8a..65556fc 100644
--- a/drivers/tty/serial/8250/8250_core.c
+++ b/drivers/tty/serial/8250/8250_core.c
@@ -2333,9 +2333,11 @@ serial8250_do_set_termios(struct uart_port *port, struct ktermios *termios,
* the trigger, or the MCR RTS bit is cleared. In the case where
* the remote UART is not using CTS auto flow control, we must
* have sufficient FIFO entries for the latency of the remote
- * UART to respond. IOW, at least 32 bytes of FIFO.
+ * UART to respond. IOW, at least 32 bytes of FIFO. Also enable
+ * AFE if hw flow control is supported
*/
- if (up->capabilities & UART_CAP_AFE && port->fifosize >= 32) {
+ if ((up->capabilities & UART_CAP_AFE && (port->fifosize >= 32)) ||
+ (port->flags & UPF_HARD_FLOW)) {
up->mcr &= ~UART_MCR_AFE;
if (termios->c_cflag & CRTSCTS)
up->mcr |= UART_MCR_AFE;
OpenPOWER on IntegriCloud