summaryrefslogtreecommitdiffstats
path: root/drivers/thermal
diff options
context:
space:
mode:
authorZhang Rui <rui.zhang@intel.com>2013-04-25 00:57:22 +0800
committerZhang Rui <rui.zhang@intel.com>2013-04-25 00:57:22 +0800
commiteea2d4812dbe14a00f657641a0ac3ba0a36ad33c (patch)
tree7e3cce83ca46daf0a99bff186489d83c0b31553b /drivers/thermal
parenta502be187385666441d4d6fe66efd4179a74d779 (diff)
parenta00e55f9c8c06e2bba5db5f2e7dec16b86d560ec (diff)
downloadop-kernel-dev-eea2d4812dbe14a00f657641a0ac3ba0a36ad33c.zip
op-kernel-dev-eea2d4812dbe14a00f657641a0ac3ba0a36ad33c.tar.gz
Merge branch 'thermal_core-doc-comments-update' of .git into next
Diffstat (limited to 'drivers/thermal')
-rw-r--r--drivers/thermal/thermal_core.c80
1 files changed, 57 insertions, 23 deletions
diff --git a/drivers/thermal/thermal_core.c b/drivers/thermal/thermal_core.c
index c0779ad..f36cd44 100644
--- a/drivers/thermal/thermal_core.c
+++ b/drivers/thermal/thermal_core.c
@@ -40,7 +40,7 @@
MODULE_AUTHOR("Zhang Rui");
MODULE_DESCRIPTION("Generic thermal management sysfs support");
-MODULE_LICENSE("GPL");
+MODULE_LICENSE("GPL v2");
static DEFINE_IDR(thermal_tz_idr);
static DEFINE_IDR(thermal_cdev_idr);
@@ -446,7 +446,7 @@ void thermal_zone_device_update(struct thermal_zone_device *tz)
for (count = 0; count < tz->trips; count++)
handle_thermal_trip(tz, count);
}
-EXPORT_SYMBOL(thermal_zone_device_update);
+EXPORT_SYMBOL_GPL(thermal_zone_device_update);
static void thermal_zone_device_check(struct work_struct *work)
{
@@ -1109,13 +1109,23 @@ thermal_remove_hwmon_sysfs(struct thermal_zone_device *tz)
#endif
/**
- * thermal_zone_bind_cooling_device - bind a cooling device to a thermal zone
- * @tz: thermal zone device
+ * thermal_zone_bind_cooling_device() - bind a cooling device to a thermal zone
+ * @tz: pointer to struct thermal_zone_device
* @trip: indicates which trip point the cooling devices is
* associated with in this thermal zone.
- * @cdev: thermal cooling device
+ * @cdev: pointer to struct thermal_cooling_device
+ * @upper: the Maximum cooling state for this trip point.
+ * THERMAL_NO_LIMIT means no upper limit,
+ * and the cooling device can be in max_state.
+ * @lower: the Minimum cooling state can be used for this trip point.
+ * THERMAL_NO_LIMIT means no lower limit,
+ * and the cooling device can be in cooling state 0.
*
+ * This interface function bind a thermal cooling device to the certain trip
+ * point of a thermal zone device.
* This function is usually called in the thermal zone device .bind callback.
+ *
+ * Return: 0 on success, the proper error value otherwise.
*/
int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
int trip,
@@ -1209,16 +1219,21 @@ free_mem:
kfree(dev);
return result;
}
-EXPORT_SYMBOL(thermal_zone_bind_cooling_device);
+EXPORT_SYMBOL_GPL(thermal_zone_bind_cooling_device);
/**
- * thermal_zone_unbind_cooling_device - unbind a cooling device from a thermal zone
- * @tz: thermal zone device
+ * thermal_zone_unbind_cooling_device() - unbind a cooling device from a
+ * thermal zone.
+ * @tz: pointer to a struct thermal_zone_device.
* @trip: indicates which trip point the cooling devices is
* associated with in this thermal zone.
- * @cdev: thermal cooling device
+ * @cdev: pointer to a struct thermal_cooling_device.
*
+ * This interface function unbind a thermal cooling device from the certain
+ * trip point of a thermal zone device.
* This function is usually called in the thermal zone device .unbind callback.
+ *
+ * Return: 0 on success, the proper error value otherwise.
*/
int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
int trip,
@@ -1249,7 +1264,7 @@ unbind:
kfree(pos);
return 0;
}
-EXPORT_SYMBOL(thermal_zone_unbind_cooling_device);
+EXPORT_SYMBOL_GPL(thermal_zone_unbind_cooling_device);
static void thermal_release(struct device *dev)
{
@@ -1272,10 +1287,17 @@ static struct class thermal_class = {
};
/**
- * thermal_cooling_device_register - register a new thermal cooling device
+ * thermal_cooling_device_register() - register a new thermal cooling device
* @type: the thermal cooling device type.
* @devdata: device private data.
* @ops: standard thermal cooling devices callbacks.
+ *
+ * This interface function adds a new thermal cooling device (fan/processor/...)
+ * to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
+ * to all the thermal zone devices registered at the same time.
+ *
+ * Return: a pointer to the created struct thermal_cooling_device or an
+ * ERR_PTR. Caller must check return value with IS_ERR*() helpers.
*/
struct thermal_cooling_device *
thermal_cooling_device_register(char *type, void *devdata,
@@ -1301,7 +1323,7 @@ thermal_cooling_device_register(char *type, void *devdata,
return ERR_PTR(result);
}
- strcpy(cdev->type, type ? : "");
+ strlcpy(cdev->type, type ? : "", sizeof(cdev->type));
mutex_init(&cdev->lock);
INIT_LIST_HEAD(&cdev->thermal_instances);
cdev->ops = ops;
@@ -1346,7 +1368,7 @@ unregister:
device_unregister(&cdev->device);
return ERR_PTR(result);
}
-EXPORT_SYMBOL(thermal_cooling_device_register);
+EXPORT_SYMBOL_GPL(thermal_cooling_device_register);
/**
* thermal_cooling_device_unregister - removes the registered thermal cooling device
@@ -1406,7 +1428,7 @@ void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
device_unregister(&cdev->device);
return;
}
-EXPORT_SYMBOL(thermal_cooling_device_unregister);
+EXPORT_SYMBOL_GPL(thermal_cooling_device_unregister);
void thermal_cdev_update(struct thermal_cooling_device *cdev)
{
@@ -1432,7 +1454,7 @@ void thermal_cdev_update(struct thermal_cooling_device *cdev)
EXPORT_SYMBOL(thermal_cdev_update);
/**
- * notify_thermal_framework - Sensor drivers use this API to notify framework
+ * thermal_notify_framework - Sensor drivers use this API to notify framework
* @tz: thermal zone device
* @trip: indicates which trip point has been crossed
*
@@ -1443,16 +1465,21 @@ EXPORT_SYMBOL(thermal_cdev_update);
* The throttling policy is based on the configured platform data; if no
* platform data is provided, this uses the step_wise throttling policy.
*/
-void notify_thermal_framework(struct thermal_zone_device *tz, int trip)
+void thermal_notify_framework(struct thermal_zone_device *tz, int trip)
{
handle_thermal_trip(tz, trip);
}
-EXPORT_SYMBOL(notify_thermal_framework);
+EXPORT_SYMBOL_GPL(thermal_notify_framework);
/**
- * create_trip_attrs - create attributes for trip points
+ * create_trip_attrs() - create attributes for trip points
* @tz: the thermal zone device
* @mask: Writeable trip point bitmap.
+ *
+ * helper function to instantiate sysfs entries for every trip
+ * point and its properties of a struct thermal_zone_device.
+ *
+ * Return: 0 on success, the proper error value otherwise.
*/
static int create_trip_attrs(struct thermal_zone_device *tz, int mask)
{
@@ -1553,7 +1580,7 @@ static void remove_trip_attrs(struct thermal_zone_device *tz)
}
/**
- * thermal_zone_device_register - register a new thermal zone device
+ * thermal_zone_device_register() - register a new thermal zone device
* @type: the thermal zone device type
* @trips: the number of trip points the thermal zone support
* @mask: a bit string indicating the writeablility of trip points
@@ -1566,8 +1593,15 @@ static void remove_trip_attrs(struct thermal_zone_device *tz)
* whether trip points have been crossed (0 for interrupt
* driven systems)
*
+ * This interface function adds a new thermal zone device (sensor) to
+ * /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
+ * thermal cooling devices registered at the same time.
* thermal_zone_device_unregister() must be called when the device is no
* longer needed. The passive cooling depends on the .get_trend() return value.
+ *
+ * Return: a pointer to the created struct thermal_zone_device or an
+ * in case of error, an ERR_PTR. Caller must check return value with
+ * IS_ERR*() helpers.
*/
struct thermal_zone_device *thermal_zone_device_register(const char *type,
int trips, int mask, void *devdata,
@@ -1606,7 +1640,7 @@ struct thermal_zone_device *thermal_zone_device_register(const char *type,
return ERR_PTR(result);
}
- strcpy(tz->type, type ? : "");
+ strlcpy(tz->type, type ? : "", sizeof(tz->type));
tz->ops = ops;
tz->tzp = tzp;
tz->device.class = &thermal_class;
@@ -1699,7 +1733,7 @@ unregister:
device_unregister(&tz->device);
return ERR_PTR(result);
}
-EXPORT_SYMBOL(thermal_zone_device_register);
+EXPORT_SYMBOL_GPL(thermal_zone_device_register);
/**
* thermal_device_unregister - removes the registered thermal zone device
@@ -1766,7 +1800,7 @@ void thermal_zone_device_unregister(struct thermal_zone_device *tz)
device_unregister(&tz->device);
return;
}
-EXPORT_SYMBOL(thermal_zone_device_unregister);
+EXPORT_SYMBOL_GPL(thermal_zone_device_unregister);
/**
* thermal_zone_get_zone_by_name() - search for a zone and returns its ref
@@ -1882,7 +1916,7 @@ int thermal_generate_netlink_event(struct thermal_zone_device *tz,
return result;
}
-EXPORT_SYMBOL(thermal_generate_netlink_event);
+EXPORT_SYMBOL_GPL(thermal_generate_netlink_event);
static int genetlink_init(void)
{
OpenPOWER on IntegriCloud