summaryrefslogtreecommitdiffstats
path: root/drivers/staging/cxt1e1/linux.c
diff options
context:
space:
mode:
authorGreg Kroah-Hartman <gregkh@suse.de>2010-10-28 09:44:56 -0700
committerGreg Kroah-Hartman <gregkh@suse.de>2010-10-28 09:44:56 -0700
commite4c5bf8e3dca827a1b3a6fac494eae8c74b7e1e7 (patch)
treeea51b391f7d74ca695dcb9f5e46eb02688a92ed9 /drivers/staging/cxt1e1/linux.c
parent81280572ca6f54009edfa4deee563e8678784218 (diff)
parenta4ac0d847af9dd34d5953a5e264400326144b6b2 (diff)
downloadop-kernel-dev-e4c5bf8e3dca827a1b3a6fac494eae8c74b7e1e7.zip
op-kernel-dev-e4c5bf8e3dca827a1b3a6fac494eae8c74b7e1e7.tar.gz
Merge 'staging-next' to Linus's tree
This merges the staging-next tree to Linus's tree and resolves some conflicts that were present due to changes in other trees that were affected by files here. Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
Diffstat (limited to 'drivers/staging/cxt1e1/linux.c')
-rw-r--r--drivers/staging/cxt1e1/linux.c20
1 files changed, 10 insertions, 10 deletions
diff --git a/drivers/staging/cxt1e1/linux.c b/drivers/staging/cxt1e1/linux.c
index eb0f4bd..c793028 100644
--- a/drivers/staging/cxt1e1/linux.c
+++ b/drivers/staging/cxt1e1/linux.c
@@ -112,13 +112,13 @@ int log_level = LOG_ERROR;
int log_level_default = LOG_ERROR;
module_param(log_level, int, 0444);
-int max_mru = MUSYCC_MRU;
+int cxt1e1_max_mru = MUSYCC_MRU;
int max_mru_default = MUSYCC_MRU;
-module_param(max_mru, int, 0444);
+module_param(cxt1e1_max_mru, int, 0444);
-int max_mtu = MUSYCC_MTU;
+int cxt1e1_max_mtu = MUSYCC_MTU;
int max_mtu_default = MUSYCC_MTU;
-module_param(max_mtu, int, 0444);
+module_param(cxt1e1_max_mtu, int, 0444);
int max_txdesc_used = MUSYCC_TXDESC_MIN;
int max_txdesc_default = MUSYCC_TXDESC_MIN;
@@ -1118,12 +1118,12 @@ c4_mod_init (void)
if (log_level != log_level_default)
pr_info("NOTE: driver parameter <log_level> changed from default %d to %d.\n",
log_level_default, log_level);
- if (max_mru != max_mru_default)
- pr_info("NOTE: driver parameter <max_mru> changed from default %d to %d.\n",
- max_mru_default, max_mru);
- if (max_mtu != max_mtu_default)
- pr_info("NOTE: driver parameter <max_mtu> changed from default %d to %d.\n",
- max_mtu_default, max_mtu);
+ if (cxt1e1_max_mru != max_mru_default)
+ pr_info("NOTE: driver parameter <cxt1e1_max_mru> changed from default %d to %d.\n",
+ max_mru_default, cxt1e1_max_mru);
+ if (cxt1e1_max_mtu != max_mtu_default)
+ pr_info("NOTE: driver parameter <cxt1e1_max_mtu> changed from default %d to %d.\n",
+ max_mtu_default, cxt1e1_max_mtu);
if (max_rxdesc_used != max_rxdesc_default)
{
if (max_rxdesc_used > 2000)
OpenPOWER on IntegriCloud